MP 450W/650W/1000W Modular Power series MODEL:MD-100U OUTPUT FUNCTION TEST NO 1 2 3 4 5 6 TEST ITEM SPECICATION TEST CONDITION RIPPLE & NOISE V1: 200 mVp-p (Max ) I/P: 230VAC RESULT V1: 15 mVp-p (Max ) VERDICT V2: 100 mVp-p (Max ) O/P:FULL LOAD Ta:25℃ V2: 20 mVp-p (Max ) OUTPUT VOLTAGE CH1: 22.8 V~ 26.4 V I/P: 230 VAC 21.33 V~ 27.59 V/ 230 VAC ADJUST RANGE CH2: 4.75 V~ 5.5 V O/P:MIN LOAD Ta:25℃ 4.49 V~ 5.82 V/ 230 VAC OUTPUT VOLTAGE V1: 3 %~ -3 % (Max) I/P: 85 VAC / 264 VAC V1: 0.2 %~ -0.2 % TOLERANCE V2: 3 %~ -3 % (Max) O/P:FULL/ MIN LOAD Ta:25℃ V2: 0.12 %~ -0.12 % V1: 1 %~ -1 % (Max) I/P: 85 VAC ~ 264 VAC V1: 0.03 %~ -0.03 % V2: 1 %~ -1 % (Max) O/P:FULL LOAD Ta:25℃ V2: 0 %~ 0 % V1: 2 %~ -2 % (Max) I/P: 230 VAC V1: 0.08 %~ -0.08 % V2: 2 %~ -2 % (Max) O/P:FULL ~MIN LOAD Ta:25℃ V2: 0.12 %~ -0.12 % V1: 2 %~ -2 % (Max) I/P: 230 VAC V1: 0.15 %~ -0.15 % V2: 2 %~ -2 % (Max) O/P: Testing O/P 60%LOAD V2: 0.12 %~ -0.12 % LINE REGULATION LOAD REGULATION CROSS REGULATION P P P P P Other O/P 40%LOAD P Change Ta:25℃ 7 SET UP TIME 230VAC: 1500 ms (Max) I/P: 230 VAC 230VAC/ 924 ms I/P: 115 VAC P O/P:FULL LOAD Ta:25℃ 8 RISE TIME 230VAC: 50 ms (Max) I/P: 230 VAC 230VAC/ 11 ms I/P: 115 VAC P O/P:FULL LOAD Ta:25℃ 9 HOLD UP TIME 230VAC: 20 ms(TYP) I/P: 230 VAC 230VAC/ 188 ms I/P: 115 VAC P O/P:FULL LOAD Ta:25℃ 10 OVER/UNDERSHOOT TEST I/P: 230 VAC < +5% TEST: <5 % O/P:FULL LOAD Ta:25℃ 11 DYNAMIC LOAD V1: 2400 mVp-p I/P: 230 VAC P 471 mVp-p O/P:FULL /Min LOAD P 90%DUTY/1KHZ Ta:25℃ Model: MD-100U Test Report 1 / 4 MP 450W/650W/1000W Modular Power series INPUT FUNCTION TEST NO 1 TEST ITEM SPECICATION TEST CONDITION INPUT VOLTAGE RANGE 85VAC~264 VAC) I/P:TESTING RESULT VERDICT 36V~264V O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V= 82 V P HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE 47HZ ~63 HZ I/P: 85 VAC ~ 264 VAC NO DAMAGE OSC O/P:FULL~MIN LOAD Ta:25℃ TEST: OK P PROTECTION FUNCTION TEST NO 1 2 TEST ITEM OVER LOAD PROTECTION OVER VOLTAGE PROTECTION SPECICATION TEST CONDITION RESULT I/P: 230 VAC 141 %/ 230 VAC I/P: 115 VAC 142 %/ 115 VAC O/P:TESTING Ta:25℃ Shunt down Re-power ON CH1: 26.5 V~ 34 V I/P: 230 VAC CH1: 30.3 V/ 230 VAC CH2: 5.6 V~ 7.2 V I/P: 115 VAC 116 %~ 150 % O/P:MIN LOAD Ta:25℃ VERDICT P 30.3 V/ 115 VAC CH2: 6.13 V/ 230 VAC P 6.13 V/ 115 VAC Shunt down Re- power ON 3 SHORT PROTECTION SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Ta:25℃ Shunt down Re-power ON P CONTROL FUNCTION TEST NO 3 TEST ITEM SPECICATION TEST CONDITION RESULT REMOTE CONTROL Rc+ / Rc- I/P: 230 VAC open or 0V ~ 3 V POWER ON open or 0V~0.8V POWER ON O/P:FULL LOAD Ta:25℃ 4V~12V POWER OFF VERDICT 3.1V ~ 12V POWER OFF Model: MD-100U Test Report P 2 / 4 MP 450W/650W/1000W Modular Power series SAFETY TEST NO 1 2 TEST ITEM SPECICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3 KVAC/min I/P-O/P: 3.6 KVAC/min I/P-O/P: 4.18 mA I/P-FG: 1.5 KVAC/min I/P-FG: 1.8 KVAC/min I/P-FG: 3.33 mA O/P-FG: 0.5 KVAC/min O/P-FG: 0.6 KVAC/min Ta:25℃ O/P-FG: 6.51 mA I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 12 GΩ I/P-FG: 500VDC>100MΩ I/P-FG: 500 VDC O/P-FG:500VDC>100MΩ O/P-FG: 500 Ta:25℃ VDC I/P-FG: 11 GΩ O/P-FG: 11 GΩ ISOLATION RESISTANCE VERDICT P NO DAMAGE P NO DAMAGE E.M.C TEST NO 1 2 3 4 5 TEST ITEM SPECICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P: 230 VAC/50HZ PASS CLASS A O/P:FULL LOAD Ta:25℃ EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL/50% LOAD Ta:25℃ Test by certified Lab CONDUCTION RADIATION E.S.D E.F.T 6 SURGE P EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL LOAD Ta:25℃ Test by certified Lab EN61000-4-2 I/P: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY AIR:8KV / Contact:4KV O/P:FULL LOAD Ta:25℃ EN61000-4-4 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ INPUT: 1KV IEC61000-4-5 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :1KV VERDICT P P P CRITERIA A P CRITERIA A P L,N-PE:2KV 7 Test by certified Lab & Test Report Prepare Model: MD-100U Test Report 3 / 4 MP 450W/650W/1000W Modular Power series COMPONENT STRESS TEST NO 1 TEST ITEM SPECICATION TEST CONDITION RESULT Power Transistor Q 401 Rated I/P:High-Line +3V = 267 V (1) 608 V ( D to S) or (C to E) Peak Voltage 2SK2651 : 900V O/P: (1)Full Load Turn on (2) 816 V (3) 428 V 6A (2) Full Load VERDICT P (3)Output Short Ta:25℃ 2 Diode Peak Voltage D451 Rated I/P:High-Line +3V = 267 V (1) 97.6 V BYQ28X-200 : 200V 10A O/P: (1)Full Load Turn on (2) 114 V (3) 0 V (1) 27.8 V (2) 31 V (3) 0 V (2) Full Load (3)Output Short Ta:25℃ D451 Rated YG838C04 : 40V 3 Clamp Diode Peak Voltage 30A D401 Rated I/P:High-Line +3V = 267 V (1) 812 V HER208 : 1KV 2A O/P: (1)Full Load (2) 812 V P P (2) Dynamic Load 90%Duty/1KHz Ta:25℃ 4 Input Capacitor Voltage C14 Rated : 330 u / 450V/ 105℃ I/P:High-Line +3V = 267 V (1) 432 V O/P: (1)Full Load Turn on /Off (2) 432 V (2) Min load Turn on /Off (3) 410 V (3)Full Load /Min load Change Ta:25℃ 5 Control IC Voltage Test P U 401 Rated I/P:High-Line +3V = 267 V (1) 14.2 V 3845 : 30V O/P: (1)Full Load Turn on /Off (2) 13.5 V (2) Min load Turn on /Off (3) 14.2 V P (3)Full Load /Min load Change Ta:25℃ DATE SAMPLE TEST RESULT TESTER APPROVAL 2004/10/7 RD SAMPLE PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN 2005/1/10 2005/3/8 PRODUCT SAMPLE W0410C39 PRODUCT SAMPLE W0501E27 2003/12/12 A50-F023 Model: MD-100U Test Report 4 / 4