Telecom-Datacom Circuit Protection Selector Guide

Telecom/Datacom
Circuit Protection
SELECTOR GUIDE
Product Selector Guide
M-SERIES
L-SERIES
A-SERIES
NUMBER OF POLES
1-2
1-3
1-6 (handle);
1-3 (rocker & metal toggle)
ACTUATOR STYLE
Solid Color Angled Rocker
Two Color Visi-Rocker
Illuminated Angled Rocker
Illuminated Flat Rocker
Solid Color Paddle
Solid Color Baton
Solid Color Push-to-Reset Pushbutton
Solid Color Push-Pull Pushbutton
Rocker, with or without guard
Sealed Metal Toggle, Handle, Rocker, Paddle
AVAILABLE DELAYS
Instant, Short, Medium AC/DC, Hi-Inrush
AC: Ultrashort, Short, Medium, Long, ShortHigh Inrush, Medium-High Inrush, Long-High
Inrush
Instantaneous, Ultra-short,
Short, Medium & Long, AC,
DC, AC/DC
High Inrush - Short, Medium
& Long AC and DC
MAXIMUM
CURRENT
& VOLTAGE
RATINGS
0.02-15FLA, 32VDC, 125VAC, 1 pole
15.1-25GPA, 32VDC, 125VAC, 1-pole
0.02-15FLA, 65VDC, 250VAC, 2-pole
15.1-25GPA, 65VDC, 250VAC, 2-pole
0.02-12FLA, 250VAC, 1-pole
0.02-7.5GPA, 50VDC, 1-pole
0.02-30GPA, 65VDC, 80VDC, 1 pole
31-50GPA, 80VDC, Parallelv
.2-30A, 120/240-240VAC
0.02 -30A@277VAC, 80VDC
MAXIMUM
INTERRUPTING
CAPACITY
1,000A @ 65VDC, 2-pole
1,000A @ 32VDC, 1-pole
1,000A @ 250VAC, 2-pole
1,000A @ 125VAC, 1-pole
600A @ 80VDC
5000 Amps
AUXILIARY
SWITCH RATING
7A @ 250VAC
0.1A @ 125VAC (gold contacts)
7A (Res.) @ 28VDC
4A (Ind.) @ 28VDC
0.25A @ 80VDC
N/A
10.1A@125VAC
0.1A@125VAC (gold contacts)
0.5A@65VDC
0.1A@80VDC
AVAILABLE
CIRCUITS
Series and Switch Only
Parallel Pole
Series Trip
Series, Shunt, Relay, Switch
Only, Series w/ Remote
Shutdown, Relay & Shunt
Trip Dual Coil
TERMINAL
OPTIONS
.250” QC Tabs
8-32 Screw w/ Upturned Lugs
8-32, 10-32 Screw (Bus Type)
Push in Stud Terminals
10-32, 8-32, M5 & M4 Screw
.250” QC Tabs,
8-32 & 10-32 Screw
(& metric), PCB
Threaded Insert: #6-32 UNC-2B, or M3X0.56H B ISO (2 per Pole)
Threaded inserts:
Front Panel Snap-In
UL 489, CUL, TUV (EN60934-2)
UL, CSA, VDE, TUV (rocker),
UL1500, UL489A
MOUNTING METHOD Snap-in Front Panel Threaded Bushing
AGENCY
APPROVALS
www.carlingtech.com
UL recognized, CSA,
VDE, TUV, UL489A Listed
31.0-50A@125/250VAC, 65VDC
7500A @ 65 VDC, UL only
3000A @ 125/250VAC, UL only
5000A @ 277VAC, w/ fuse backup
Product Selector Guide
B-SERIES
C-SERIES
F-SERIES
CX-SERIES
1-6
1-6 (handle);
1-3 (rocker & metal toggle)
1- 2, + Auxiliary Switch Pole
1-3
Handle, Rocker
Sealed Metal Toggle,
Handle, Rocker
Handle, 1 per pole
Handle
Instantaneous, Ultra-short,
Short, Medium & Long, AC,
DC, AC/DC
High Inrush - Short, Medium
& Long AC and DC
Instantaneous, Ultrashort,
Short, Medium &
Long, AC, DC, AC/DC
High Inrush - Short, Medium
& Long AC and DC
DC: Instantaneous, Ultrashort, Short,
Medium & Long
Short, Medium & Long
DC, AC
0.02 -30A@277VAC, 80VDC
UL Listed
0.02-250A@80VDC
0.1-100@125VDC
0.02-70A@120VAC
0.02-20A@240VAC
ULRecognized
0.02-30A@480WYE
/277VAC2-pole, 1Ø,
3-pole, 3Ø
0.02-50A@277VAC
0.02-100A@250VAC,80VDC
0.02-100A@120/240VAC, 65VDC
UL Recognized .2 -125A, 600VDC
UL Listed .2-15A, 250/500VDC
UL489 Listed:
50-250A@125VDC
100-250A@120/240VAC
100-250A@277VAC
100-250A@208Y/120 3Ø
UL489A Listed
250-700A@125VDC
7500A@80 VDC, UL only
3000A@125/250VAC, UL only
5000A@277VAC, w/ fuse backup
UL Listed
50000A@80VDC, single pole only
10,000A@120VAC,
5000A@125VDC,
240VAC
ULRecognized
7500A@80VDC
3000A@125/250VAC, UL only
5000A@250VAC - listed construction
5000A@480WYE/277V
AC w/fuse backup
Up to 10,000 UL Listed and
UL recognized
50000A@125VDC
10000A, 120/240, 277, 208Y/120
10.1A@125VAC
0.1A@125VAC (gold contacts)
0.5A@65VDC
0.1A@80VDC
10.1A@250VAC
0.1A@125VAC (gold contacts)
0.5A@65VDC
20A, 80VDC (GO circuit)
10.1A@250VAC
0.5A@65VDC
0.1A@80VDC
Series, Shunt, Relay, Switch
Only, Series w/ Remote
Shutdown, Relay & Shunt
Trip Dual Coil, Mid-Trip with
Alarm Switch
Series, Shunt,Relay,
Switch Only, Series
w/ Remote Shutdown,
Relay & Shunt Trip Dual
Coil,Mid-Trip with Alarm Switch
Series Trip
Series & Switch Only
with or without Metering Shunt
AVAILABLE
CIRCUITS
.250” QC Tabs,
8-32 & 10-32 Screw
(& metric), PCB
10-32 Stud, 1/4-20 Stud,
0-32 Screw w/ saddle
clamp,Clip Terminal,
1/4 & 7/16 Push-In
10-32 or M5 Screw Terminals 1/4-20 or
M6 Threaded Stud
3/8-16 Stud, 3/8-16
Screw & Box Wire Connector
TERMINAL
OPTIONS
Threaded inserts:
Front Panel Snap-In
Threaded inserts
Threaded insert: #6-32 UNC-2B, or
M3X0.5-6H B ISO (2 per pole)
Rear or Front Panel
UL, CSA, VDE, TUV (rocker),
UL1500, UL489, UL489A
UL, CSA, VDE, TUV,
UL1500, UL489, UL489A
UL489, UL1077, TUV (EN60934-2)
CUL,TUV, UL489,
UL489A
31.0-50A@125/250VAC, 65VDC
NUMBER OF POLES
ACTUATOR STYLE
AVAILABLE DELAYS
MAXIMUM
CURRENT
& VOLTAGE
RATINGS
MAXIMUM
INTERRUPTING
CAPACITY
AUXILIARY
SWITCH RATING
MOUNTING METHOD
AGENCY
APPROVALS
www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe / Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
TELE/DATA-SG_01_2014