Ground Fault Circuit Protection • PB-Series • PD-Series (SmartGuard®) Transforming Customer Needs into Customer Solutions At Carling Technologies, we do much more than manufacture electrical components. We engineer powerful solutions. Working closely with your product team, we can tailor switching and circuit protection solutions that meet your application needs — cost effectively. Since our founding in 1920, there are few products we havenʼt turned on, fewer industries that havenʼt turned to us. With five ISO certified manufacturing locations and technical sales offices worldwide, Carling Technologies now ranks among the worldʼs largest privately owned manufacturers of hydraulic/magnetic circuit breakers, thermal circuit protectors, electrical switches and assemblies, power distribution centers and electronic control systems. In regard to circuit protection, we lead the industry in delivering higher ratings in smaller packages. And what makes all our breakers especially attractive is their superior performance and reliability ––– both hallmarks of Carling Technologies . Our Ground Fault Circuit Protection products are specifically designed for those applications that could benefit from having overload, short circuit & ground fault protection in a single package. The PB-Series and PD-Series Smartguard can be used to protect several different types of equipment. Applications include: • • • • • • generators solar photovotaic systems marine control panels de-icing & snowmelting equipment resistance & impedence heating systems telecommunications Customer Care Center • • • • • • • stage /theatre lighting office machines medical equipment industrial automation industrial control UPS Systems welders For application assistance, we urge you to consult with our experienced staff in our Customer Care Center. Our Technical and Engineering staff has extensive test, research and development capabilities, and have assisted many customers in solving unique design and application problems with standard or customized products. Please refer to our location listing on the back of this catalog, for contact information for your area. We look forward to working with you. Contents AC Branch & Main Ground Fault Protection Product Specifications & Ordering Information PB-Series General Specifications Ordering Scheme Dimensional Specifications Wiring Diagrams SMARTGUARD PD-Series General Specifications Ordering Scheme Circuit & Terminal Diagrams Page 1 2 4 5 7 8 10 11 www.carlingtech.com AC Branch & Main Ground Fault Protection Reduce the risk of fire and shock hazards caused by defects in circuit wiring Ground fault Circuit Interrupter (GFCI) – Homeowners may be familiar with Ground Fault Circuit Interrupters (GFCI) as an integral part of modern AC electrical receptacles. GFCIs immediately switch electricity OFF when electricity “leakage” to ground is detected. This leakage is detected as an imbalance in current between the Hot and Neutral AC wiring. The imbalance indicates a ground fault, current leaking from its proper circuit path to ground, and possibly through a human body in the process. Circuit Breaker + GFCI The ground fault protection of a GFCI can be combined with the familiar over-current tripping characteristics of a normal circuit breaker in a single device. Typical Marine Application: www.carlingtech.com There are two main categories of circuit breaker with GFCI: • 5mA - suitable for AC branch circuit ground fault protection • > 5mA, typically 30mA - suitable for AC main circuit ground fault protection AC Branch Ground Fault Circuit Protection – 5mA Single Circuit Solution Installed in a power distribution panel to provide a single circuit solution. These single pole devices combine the 5mA ground fault protection function of a GFCI with the over-current tripping characteristics of a typical circuit breaker. Panel mounted GFCIs are much easier to locate than tracking down the multiple locations where GFCIs mounted in receptacles can exist. AC Main Ground Fault Circuit Protection – 30mA Whole-System Solution Ground fault protection also can be applied to an entire AC electrical system. Main circuit breakers with GFCI typically have a 30mA trip level, compared to the 5mA trip level of branch GFCIs. Main circuit breakers with GFCI trip at 30mA instead of 5mA to reduce nuisance trips. These devices are useful in reducing hazards occurring from ground faults in wiring and permanently installed appliances. These types of faults can result in a shock hazard and a fire hazard. Circuit breakers with GFCI should be installed at the AC Main input or as far upstream in the wiring distribution system as possible. 1 PB-Series – General Specifications PB-Series • • • • • • Overload, short circuit and ground fault protection in a single package! The PB-series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. The new PB-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. The PB-Series is suitable for: • • Portable generator ground fault protection Key Benefits of the PB-Series: AC branch ground fault protection - a single circuit solution AC main ground fault protection for a boatʼs entire AC electrical system Agency Certifications UL Listed Increases safety around boats and marinas Protects against electrical shock hazards in areas near water Protects against defects in the wires & conductors Reduces fire and shock hazards from defects in permanently installed appliances such as water heaters, battery chargers, lighting fixtures, etc. Detects lower level ground faults which do not trip ordinary circuit breakers, but can lead to fires, and shock hazards for boating occupants Innovative Features These precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heatinduced nuisance tripping is avoided. • Overload, short circuit and ground fault protection in a single package • Handle style actuators and rocker style acuguard” • Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive contact pressure & longer contact life • A trip-free mechanism, a safety feature, makes it impossible to manually hold the contacts closed during overload or fault conditions. • A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. • Front panel mounting UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077 Supplementary Protectors UL Standard 1053 Ground Fault Sensing and Relaying Equipment UL Standard 1500 Ignition Protection UL Standard 943 Class A Ground Fault Circuit Interruptors Electrical Table A: UL Listed configurations and performance capabilities as Circuit Breakers VOLTS 2 HERTZ (AMPS) www.carlingtech.com PB-Series – General Specifications Electrical Maximum Voltage Current Ratings Insulation Resistance Dielectric Strength Impedance 120/240VAC 60 Hz Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0 & 30.0 amps. Other ratings available, see ordering scheme. Minimum of 100 Megohms at 500 VDC. UL, CUL - 1500 V 60 Hz for one minute between all electrically isolated terminals. PB-Series circuit breakers comply with the 8mm spacing and 3750V 60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces and between adjacent poles Values from Line to Load Terminal. p 1000 1 0.1 0.001 0.01 0.1 1 10 100 AMPERE RATING CURRENT (AMPS) TOLERANCE (%) 5.1 - 20.0 ± 25% 0.100 - 5.0 20.1 - 30.0 ± 15% ± 35% FIGURE 1 20.1 - 30.0 Pulse Tolerance Curve 60 Hz 1/2 Cycle Inrush Pulse Tolerance Multiple of Rated Current Ir Time Delay Curves 22, 24, 26 12x 4.165 Standard Must Trip Leakage Current Ratings Trip Time Test Button www.carlingtech.com Trip Free Trip Indication Physical Number of Poles Internal Circuit Config. Weight Environmental 10 0.01 Leakage To Ground Endurance Standard Colors 100 O H M S Mechanical 8.33 16.67 t Time in Milliseconds 5 & 30 milliamps. 5± 1mA for UL943, other leakage ratings test to UL1053. For other ratings, consult factory. 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. On unit face along side of actuator. 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. All PB-Series Circuit Breakers will trip on overload or ground fault, even when Handle is forcibly held in the ON position. The operating Handle moves positively to the OFF position when an overload or ground fault causes the breaker to trip. 1 - 3 poles, where the third pole is neutral Series Trip Approximately 65 grams/pole. (Approximately 2.32 ounces/pole.) Housing- Black; Actuator - See Ordering Scheme. Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition "I". Ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -35° C to +65° C Corrosion Tested per UL943 FMG Test. 3 weeks @ 30°C 75% RH, 100ppb H2S, 20ppb CI2, 200ppb NO2 3 PB A – B A – 24 – 620 – 2 B A – A G PB-Series – Ordering Scheme 1 Series 1 SERIES PB 2 System Voltage/Poles 3 Circuit 4 Actuator 5 Frequency & Delay 2 SYSTEM VOLTAGE / POLES A 120 VAC single phase, one pole B 120/240 VAC single phase, two pole C 120/240 VAC single phase with switched neutral, three pole 3 CIRCUIT B Series Trip (Current) 4 ACTUATOR1 Handle A one per pole B one per multipole unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend 5 FREQUENCY & DELAY 22 60Hz Short 24 60Hz Medium 26 60Hz Long Single Color Curved Rocker J Vertical legend K Horizontal legend Two Color Flat Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single Color Flat Rocker 3 Vertical legend 4 Horizontal legend Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker:2 pole - left pole 3 pole - center pole 2 Screw Terminals are recommended on ratings greater than 20 amps. 3 UL & CSA up to 30 amps, but not recommended over 20 amps. 4 Available with leakage current trip level - Max trip current code E, and agency approval C. 5 6mA per UL943, available with agency approval code 6. 6 30mA per UL1053, available with agency approval codes C & 6. 7 UL1500 only available with 30mA trip level. 6 Current Rating 7 Terminal 8 Actuator Color 6 CURRENT RATING (AMPERES) 285 0.850 210 0.100 290 0.900 215 0.150 295 0.950 220 0.200 410 1.000 225 0.250 512 1.250 230 0.300 415 1.500 235 0.350 517 1.750 240 0.400 420 2.000 245 0.450 522 2.250 250 0.500 425 2.500 255 0.550 527 2.750 260 0.600 430 3.000 265 0.650 435 3.500 270 0.700 440 4.000 275 0.750 445 4.500 280 0.800 7 TERMINAL2 13 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 w/upturned lugs 3 Screw 8-32 (Bus Type) 4 Screw 10-32 w/upturned lugs 5 Screw 10-32 (Bus Type) 8 ACTUATOR COLOR & LEGEND I-O ON-OFF Dual White A B 1 Black C D 2 Red F G 3 Green H J 4 Blue K L 5 Yellow M N 6 Gray P Q 7 Orange R S 8 9 MOUNTING/BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole A 6-32 X 0.195 inches B ISO M3 x 5mm 9 Mounting/ Barriers 10 Trip Level 712 613 614 615 616 617 618 620 622 624 625 630 11 Agency Approval 450 455 460 465 470 475 480 485 490 495 610 710 611 711 612 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 B C E H Screw M5 w/upturned lugs Screw M4 w/upturned lugs Screw M4 (Bus Type) Screw M5 (Bus Type) 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 Legend Color Black White White White White Black Black Black BARRIERS yes yes 10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT A 5 mA (Class A GFCI)4,5,6 E 30 mA (ELCB) 11 AGENCY APPROVAL3 G UL489 Listed, CSA Certified C UL1077 I UL1077, UL1500 7 NOTES: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wallmount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. 4 www.carlingtech.com PB-Series – Dimensional Specifications INDICATE "ON" 1.515 MAX [38.48] 3.03 [76.9] INDICATE "OFF" AND SINGLE COLOR LINE .21 [5.3] 1.25 [31.6] TEST LOAD 2.17 [55.0] LOAD 1-POLE 120 VAC VERSION TEST LINE #6-32/M3 MOUNTING INSERTS 1.88 [47.8] LINE TERMINAL 2.265 MAX [57.53] 1.660 [42.16] 2.58 [65.6] TEST 2.37 [60.2] .375 [9.53] .39 [9.9] CURRENT TRANSFORMERS LOAD TERMINAL +.020 1.500 -.000 +.50 38.10 -.00 [ .750 TYP [19.05] 1.260 [32.00] GFCI NEUTRAL WIRE 2-POLE 120/240 VAC VERSION ] 1.660 [42.16] .20 [5.1] +.020 2.250 -.000 +.50 57.15 -.00 [ Ø .156 TYP [3.96] ] PANEL CUTOUT NEUTRAL BREAK POLE 3.015 MAX [76.58] .750 TYP [19.05] TEST 2-POLE 120/240 VAC WITH NEUTRAL BREAK Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 5 PB-Series – Dimensional Specifications Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Time Delay Curves 6 Instantaneous Medium Short Long www.carlingtech.com PB-Series – Wiring Diagrams 120VAC with Switched Neutral SYSTEM NEUTRAL 120VAC without Switched Neutral SYSTEM NEUTRAL GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LOAD NEUTRAL LOAD HOT LOAD HOT LINE/SOURCE (HOT) LINE/SYSTEM NEUTRAL LINE/SOURCE (HOT) 120 VAC LOAD 120 VAC LOAD AC SOURCE AC SOURCE 120/240VAC without Switched Neutral 120/240VAC with Switched Neutral SYSTEM NEUTRAL SYSTEM NEUTRAL GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LOAD HOT 1 LINE/SOURCE 1 120 VAC LOAD 120 VAC LOAD LOAD HOT 2 LINE/ SOURCE 2 240 VAC LOAD LOAD NEUTRAL LOAD HOT 1 LINE/SYSTEM NEUTRAL 120 VAC LOAD 120 VAC LOAD LINE/SOURCE (1) LOAD HOT (2) LINE/ SOURCE (2) 240 VAC LOAD AC SOURCE AC SOURCE www.carlingtech.com 7 PD-Series – General Specifications SmartGuard® PD-Series Innovative Features These precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heatinduced nuisance tripping is avoided. • • • • Overload, short circuit and equipment ground fault protection in a single package! Todayʼs high tech equipment demands high tech protection. Our SmartGuard Equipment Leakage Circuit Breaker (ELCB) provides that protection, in one attractive, space-saving package. SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/magnetic circuit breaker, offering customized overload and short circuit protection. In addition, this breaker senses and guards against faults to ground using a state of the art integrated circuit developed by Carling. This new technology detects faults and when a fault occurs, the breaker trips and an LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage. This protection helps prevent serious equipment damage and fire. • • • • • • Overload, short circuit and ground fault protection in a single package Handle style actuators with optional “handleguard” Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive contact pressure & longer contact life A trip-free mechanism, a safety feature, makes it impossible to manually hold the contacts closed during overload or fault conditions. A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. Front panel or DIN rail mounting options “State of the art” integrated circuit developed by Carling Equipment leakage sensitivity from 10 to 100 milliamps Integral push-to-test button and LED “tripped” indicator Immediate reset after fault has been cleared Agency Certifications UL Recognized UL Standard 1077 UL Standard 943 Component Recognition Program as Equipment Leakage Circuit Interrupter and, Protectors, Supplementary (FTTJ2, File E177510). Tested as Ground Fault Circuit Interrupters for Equipment Protection. CSA Certified Component Equipment Leakage Current Interrupter with Supplementary Protector, under Class C22.2,No. 144-M91, FIle LR47848-50 TUV Certified IEC 947-2 and appendix B: Circuit Breakers incorporating Residual Current Protection. Complies with waveform requirements of IEC 1008-1, Type A. 8 www.carlingtech.com PD-Series – General Specifications Electrical Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. PD-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER VOLTAGE CIRCUIT CONFIGURATION MAX RATING VOLTS 120/208 120/208 SERIES 208-240 480Y Table B: Lists TUV Certified configurations and performance capabilities as a Circuit breaker incorporating residual current protection. Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz Standard Current Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0 & 50.0 amps. For other ratings, consult factory. Insulation Resistance Minimum of 100 Megohms @ 500 VDC. Dielectric Strength 1960 VAC, 60 Hz for one minute between all electrically isolated terminals. Resistance, Impedance from Line to Load Terminal (Values Based on Series Trip Circuit RESISTANCE, IMPEDANCE VALUES Breaker) FREQUENCY CURRENT RATING FULL 3 1 1-50 50/60 3 3 Mechanical Endurance Trip Free Trip Indication: from Line to Load Terminals Physical 20.1 - 50.0 60 Hz 1/2 Cycle Inrush Pulse Tolerance Multiple of Rated Current Ir Time Delay Curves 22, 24, 26 12x 4.165 8.33 Pulse Tolerance Curve 16.67 t Time in Milliseconds Leakage To Ground Standard Must Trip Leakage Current Ratings Trip Time Test Button Leakage Trip Indicator www.carlingtech.com 7, 10, 15, 30, 50 & 100 milliamps. For other ratings, consult factory. 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. On breaker face above actuator. Red LED on breaker face above actuator. BACKUP FUSE (MILLIAMPS) --- 5000 --- 50/60 50/60 AMPS 1-50 AMPS 1 MUST - TRIP PURPOSE PHASE 1-50 1-30 LEAKAGE CURRENT UL / CSA LOAD HERTZ 50/60 GENERAL INTERRUPTING CAPACITY (AMPS) --- 30.1-50 WITHOUT 5000 2000 2000 RATING 7-100 7-100 7-100 7-100 10,000 ON-OFF operations @ 6 per minute; with rated current and voltage. All SmartGuard equipment leakeage circuit breakers will trip on overload or leakage to ground, even when actuator is forcibly held in the ON position. The actuator moves to the OFF position when an overload or earth leakage ground fault causes the breaker to trip. The LED is illuminated when leakage to ground causes the circuit breaker to trip. Number of Poles 2, 3 & 4 Length (included switched or unswitched neutral) 4.2 inches ( 106.7 mm) Width 2-pole: 3.0 inches (76.2 mm) 3-pole: 3.75 inches (95.3 mm) 4-pole: 4.5 inches (114.3 mm) Depth 2.5inches (63.5mm). Weight: 2-pole 16.0 oz. (453.6 gm) 3-pole: 21.4 oz. (606.7 gm) 4-pole: 26.9 oz. (762.6 gm) Standard Colors Housing - gray; Actuator - black, red, or white Mounting Front Panel or Standard 35mm Symmetrical DIN Rail (35 x 7.5 or 35 x 15mm per DIN EN5002). Termination Box Lug Environmental Operating Temperature +10°C to +50°C 9 PD R – B – 24 – 650 – B – 2 A 1 – 1 – C PD-Series – Ordering Scheme 1 Series 1 SERIES PD 2 Voltage/ Poles 3 Circuit 2 SYSTEM VOLTAGE/POLES1 System Voltage A 120VAC 1Ø B 120/240 VAC 1Ø C 120/208 VAC 1Ø, 120/240 VAC 1Ø D 120/208 VAC 1Ø, 120/240 VAC 1Ø E 208/240 VAC 3Ø F 208/240 VAC 3Ø G 208/240 VAC 3Ø P 480Y VAC 3Ø Q 480Y VAC 3Ø R 480Y VAC 3Ø 3 CIRCUIT B Series Trip (Current) 4 FREQUENCY & DELAY 20 50/60Hz Instantaneous 22 50/60Hz Short 5 CURRENT RATING (AMPERES) 410 1.000 445 4.500 512 1.250 450 5.000 415 1.500 455 5.500 517 1.750 460 6.000 420 2.000 465 6.500 522 2.250 470 7.000 425 2.500 475 7.500 527 2.750 480 8.000 430 3.000 485 8.500 435 3.500 490 9.000 440 4.000 495 9.500 Time Delay Curves 4 Frequency & Delay 5 Current Rating 9 ACTUATOR COLOR & LEGEND4 Actuator Marking: Color Color: I-O ON-OFF Dual White A B 1 Black C D 2 Red E F 3 10 MOUNTING3 1 Threaded Insert 6-32 x 0.195 inches 2 Threaded Insert ISO M3 x 6.5 mm 50/60Hz Medium 50/60Hz Long 717 618 619 620 622 624 625 630 635 640 650 10 Mounting 11 Agency Approval 17.500 18.000 19.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 Marking Color: Black White White 11 AGENCY APPROVAL C UL Recognized & CSA Certified U TUV Certified Notes: 1 Units with a switched or unswitched neutral connection are the same size as a unit with an additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the same physical size as a 3-pole unit.) Switched neutral poles contain the same overcurrent protection as the other poles. 2 The leakage currents shown will cause the breaker to trip (must-trip current). The musthold current is 67% of the must-trip current. 3 All breakers are front panel mountable using screw size shown. Breakers may also be mounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail. 4 TUV certifed units must have I-O or Dual legends. Instantaneous Medium Short Long 10 9 Actuator Color 8 ACTUATOR A Handle B Handle. with handleguard Three Three plus unswitched neutral Three plus switched neutral Three Three plus unswitched neutral Three plus switched neutral 10.000 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 8 Actuator 7 TERMINAL 2 Front Connected Box Lug Two plus switched neutral 610 710 611 711 612 712 613 614 615 616 617 7 Terminal 6 EQUIPMENT LEAKAGE - TRIP CURRENT (milliamps)2 B 7 D 15 F 50 C 10 E 30 G 100 Poles One plus unswitched neutral Two Two plus unswitched neutral 24 26 6 Equipment Leakage Trip Current www.carlingtech.com PD-Series – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. NOTES: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wallmount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. www.carlingtech.com 11 PD-Series – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 12 www.carlingtech.com carlingtech.com Our extensive web site provides in-depth, detailed information about our products and capabilities. And with offices around the world, weʼre always ready to do business, answer questions and help our customers. Call, fax or e-mail anytime to start working with a company thatʼs always ON. World-Wide Corporate Headquarters Carling Technologies, Inc. 60 Johnson Avenue Plainville, CT 06062 860/793-9281 FAX: 860/793-9231 E-mail: [email protected] www.carlingtech.com Warranty Policy Carling Technologies Europe/Middle East/Africa Carling Technologies Ltd. Devon, England Int + 44 (0)1392-364422 FAX: Int + 44 (0)1392-364477 E-mail: [email protected] Carling Technologies Asia/Pacific Carling Technologies Asia-Pacific Ltd. Kowloon, Hong Kong Int + 852-2737-2277 FAX: Int + 852-2736-9332 E-mail: [email protected] Additional Carling Technologies Offices East Region Sales Office, CT [email protected] Midwest Region Sales Office, IL [email protected] West Region Sales Office, CA [email protected] GmbH, Germany [email protected] SARL, France, [email protected] Asia-Pacific Ltd., Shanghai, China [email protected] Asia-Pacific Ltd., Japan [email protected] Pune, India [email protected] Kaohsiung, Taiwan [email protected] Carling Technologies, Inc. (Seller) warrants that goods sold hereunder shall be free of defects in material and workmanship for one year from date of shipment. In the event of such defects, the Sellerʼs only obligation shall be the replacement or the cost of the defective goods, themselves, excluding, without limitation, labor costs, which are or may be required in connection with the replacement or reinstallation of the goods. This warranty is the Sellerʼs sole obligation and excludes all other remedies or warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. This Warranty expressly excludes any and all incidental, special and/or consequential damages of any nature. Seller further disclaims any responsibility for injury to person or damage to or loss of property or value caused by any product which has been subjected to misuse, negligence, or accident; or misapplied, or modified or repaired by a person or persons not authorized by the Seller or which have been improperly installed. www.carlingtech.com GFCI4_08_a www.carlingtech.com