Ground Fault Circuit Protection

Ground Fault Circuit
Protection
• PB-Series
• PD-Series (SmartGuard®)
Transforming Customer Needs into Customer Solutions
At Carling Technologies, we do much more than manufacture electrical components. We engineer powerful solutions. Working closely with your product team, we can tailor switching and circuit protection solutions that meet your application needs — cost effectively.
Since our founding in 1920, there are few products we havenʼt turned on, fewer industries that
havenʼt turned to us. With five ISO certified manufacturing locations and technical sales offices
worldwide, Carling Technologies now ranks among the worldʼs largest privately owned manufacturers of hydraulic/magnetic circuit breakers, thermal circuit protectors, electrical switches and
assemblies, power distribution centers and electronic control systems. In regard to circuit protection, we lead the industry in delivering higher ratings in smaller packages. And what makes all
our breakers especially attractive is their superior performance and reliability ––– both hallmarks
of Carling Technologies .
Our Ground Fault Circuit Protection products are specifically designed for those applications that
could benefit from having overload, short circuit & ground fault protection in a single package.
The PB-Series and PD-Series Smartguard can be used to protect several different types of
equipment. Applications include:
•
•
•
•
•
•
generators
solar photovotaic systems
marine control panels
de-icing & snowmelting equipment
resistance & impedence
heating systems
telecommunications
Customer Care Center
•
•
•
•
•
•
•
stage /theatre lighting
office machines
medical equipment
industrial automation
industrial control
UPS Systems
welders
For application assistance, we urge you to consult with our experienced staff in our Customer
Care Center. Our Technical and Engineering staff has extensive test, research and development capabilities, and have assisted many customers in solving unique design and application
problems with standard or customized products. Please refer to our location listing on the
back of this catalog, for contact information for your area.
We look forward to working with you.
Contents
AC Branch & Main Ground Fault Protection
Product Specifications & Ordering Information
PB-Series
General Specifications
Ordering Scheme
Dimensional Specifications
Wiring Diagrams
SMARTGUARD PD-Series
General Specifications
Ordering Scheme
Circuit & Terminal Diagrams
Page
1
2
4
5
7
8
10
11
www.carlingtech.com
AC Branch & Main Ground Fault Protection
Reduce the risk of fire and shock hazards caused by defects in circuit wiring
Ground fault Circuit Interrupter (GFCI) –
Homeowners may be familiar with Ground Fault
Circuit Interrupters (GFCI) as an integral part of
modern AC electrical receptacles.
GFCIs immediately switch electricity OFF when
electricity “leakage” to ground is detected. This
leakage is detected as an imbalance in current
between the Hot and Neutral AC wiring. The imbalance indicates a ground fault, current leaking from
its proper circuit path to ground, and possibly
through a human body in the process.
Circuit Breaker + GFCI
The ground fault protection of a GFCI can be combined with the familiar over-current tripping characteristics of a normal circuit breaker in a single
device.
Typical Marine
Application:
www.carlingtech.com
There are two main categories of circuit breaker
with GFCI:
•
5mA - suitable for AC branch circuit ground
fault protection
•
> 5mA, typically 30mA - suitable for AC
main circuit ground fault protection
AC Branch Ground Fault Circuit Protection –
5mA Single Circuit Solution
Installed in a power distribution panel to provide a
single circuit solution. These single pole devices
combine the 5mA ground fault protection function of
a GFCI with the over-current tripping characteristics
of a typical circuit breaker. Panel mounted GFCIs
are much easier to locate than tracking down the
multiple locations where GFCIs mounted in receptacles can exist.
AC Main Ground Fault Circuit Protection –
30mA Whole-System Solution
Ground fault protection also can be applied to an
entire AC electrical system. Main circuit breakers
with GFCI typically have a 30mA trip level, compared to the 5mA trip level of branch GFCIs. Main
circuit breakers with GFCI trip at 30mA instead of
5mA to reduce nuisance trips. These devices are
useful in reducing hazards occurring from ground
faults in wiring and permanently installed appliances. These types of faults can result in a shock
hazard and a fire hazard. Circuit breakers with
GFCI should be installed at the AC Main input or as
far upstream in the wiring distribution system as
possible.
1
PB-Series – General Specifications
PB-Series
•
•
•
•
•
•
Overload, short circuit and ground fault protection in a single
package!
The PB-series utilizes the hydraulic magnetic principle which
provides precise operation and performance even when
exposed to extremely hot and/or cold application environments.
The new PB-Series, AC Residual Current Circuit Breaker with
Overcurrent Protection (RCBO), combines the ground fault
protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker.
The PB-Series is suitable for:
•
•
Portable generator ground fault protection
Key Benefits of the PB-Series:
AC branch ground fault protection - a single circuit
solution
AC main ground fault protection for a boatʼs entire AC
electrical system
Agency Certifications
UL Listed
Increases safety around boats and marinas
Protects against electrical shock hazards in areas near
water
Protects against defects in the wires & conductors
Reduces fire and shock hazards from defects in permanently installed appliances such as water heaters, battery
chargers, lighting fixtures, etc.
Detects lower level ground faults which do not trip ordinary
circuit breakers, but can lead to fires, and shock hazards
for boating occupants
Innovative Features
These precision mechanisms are temperature stable and are
not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heatinduced nuisance tripping is avoided.
•
Overload, short circuit and ground fault protection in a
single package
•
Handle style actuators and rocker style acuguard”
•
Wiping Contacts - Mechanical linkage with two-step
actuation – cleans contacts, provides high, positive
contact pressure & longer contact life
•
A trip-free mechanism, a safety feature, makes it
impossible to manually hold the contacts closed during
overload or fault conditions.
•
A common trip linkage between all poles, another safety
feature, ensures that an overload in one pole will trip all
adjacent poles.
•
Front panel mounting
UL Standard 489
Circuit Breakers, Molded Case, (Guide DIVQ, File E129899)
UL Standard 1077
Supplementary Protectors
UL Standard 1053
Ground Fault Sensing and Relaying Equipment
UL Standard 1500
Ignition Protection
UL Standard 943
Class A Ground Fault Circuit Interruptors
Electrical
Table A: UL Listed configurations and performance capabilities as Circuit Breakers
VOLTS
2
HERTZ
(AMPS)
www.carlingtech.com
PB-Series – General Specifications
Electrical
Maximum Voltage
Current Ratings
Insulation Resistance
Dielectric Strength
Impedance
120/240VAC 60 Hz
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0 & 30.0 amps.
Other ratings available, see ordering
scheme.
Minimum of 100 Megohms at 500
VDC.
UL, CUL - 1500 V 60 Hz for one
minute between all electrically isolated terminals. PB-Series circuit
breakers comply with the 8mm spacing and 3750V 60 Hz dielectric
requirements from hazardous voltage to operator accessible surfaces
and between adjacent poles
Values from Line to Load Terminal.
p
1000
1
0.1
0.001
0.01
0.1
1
10
100
AMPERE RATING
CURRENT
(AMPS)
TOLERANCE
(%)
5.1 - 20.0
± 25%
0.100 - 5.0
20.1 - 30.0
± 15%
± 35%
FIGURE 1
20.1 - 30.0
Pulse Tolerance Curve
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
Multiple of
Rated Current
Ir
Time Delay Curves
22, 24, 26
12x
4.165
Standard Must Trip
Leakage Current Ratings
Trip Time
Test Button
www.carlingtech.com
Trip Free
Trip Indication
Physical
Number of Poles
Internal Circuit Config.
Weight
Environmental
10
0.01
Leakage To Ground
Endurance
Standard Colors
100
O
H
M
S
Mechanical
8.33
16.67
t
Time in
Milliseconds
5 & 30 milliamps.
5± 1mA for UL943, other leakage
ratings test to UL1053.
For other ratings, consult factory.
300 ms Max. @ 100%, 40ms Max.
@ 500% of must trip leakage current.
On unit face along side of actuator.
10,000 ON-OFF operations @ 6 per
minute; with rated Current and
Voltage.
All PB-Series Circuit Breakers will
trip on overload or ground fault,
even when Handle is forcibly held in
the ON position.
The operating Handle moves positively to the OFF position when an
overload or ground fault causes the
breaker to trip.
1 - 3 poles, where the third pole is
neutral
Series Trip
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole.)
Housing- Black; Actuator - See
Ordering Scheme.
Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition "I".
Ultra-short curves tested @ 90% of
rated current.
Vibration
Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C,
Test Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98%
RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature
-35° C to +65° C
Corrosion
Tested per UL943 FMG Test. 3
weeks @ 30°C 75% RH, 100ppb
H2S, 20ppb CI2, 200ppb NO2
3
PB A – B A – 24 – 620 – 2 B A – A G
PB-Series – Ordering Scheme
1
Series
1 SERIES
PB
2
System
Voltage/Poles
3
Circuit
4
Actuator
5
Frequency
& Delay
2 SYSTEM VOLTAGE / POLES
A
120 VAC single phase, one pole
B
120/240 VAC single phase, two pole
C
120/240 VAC single phase with switched neutral, three pole
3 CIRCUIT
B
Series Trip (Current)
4 ACTUATOR1
Handle
A
one per pole
B
one per multipole unit
Two Color Curved Visi-Rocker
C
Indicate ON,
vertical legend
D
Indicate ON,
horizontal legend
F
Indicate OFF,
vertical legend
G
Indicate OFF,
horizontal legend
5 FREQUENCY & DELAY
22
60Hz Short
24
60Hz Medium
26
60Hz Long
Single Color Curved Rocker
J
Vertical legend
K
Horizontal legend
Two Color Flat Visi-Rocker
1
Indicate OFF,
vertical legend
2
Indicate OFF,
horizontal legend
Single Color Flat Rocker
3
Vertical legend
4
Horizontal legend
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:2 pole - left pole
3 pole - center pole
2
Screw Terminals are recommended on ratings greater than 20 amps.
3
UL & CSA up to 30 amps, but not recommended over 20 amps.
4
Available with leakage current trip level - Max trip current code E, and agency approval C.
5
6mA per UL943, available with agency approval code 6.
6
30mA per UL1053, available with agency approval codes C & 6.
7
UL1500 only available with 30mA trip level.
6
Current Rating
7
Terminal
8
Actuator
Color
6 CURRENT RATING (AMPERES)
285
0.850
210
0.100
290
0.900
215
0.150
295
0.950
220
0.200
410
1.000
225
0.250
512
1.250
230
0.300
415
1.500
235
0.350
517
1.750
240
0.400
420
2.000
245
0.450
522
2.250
250
0.500
425
2.500
255
0.550
527
2.750
260
0.600
430
3.000
265
0.650
435
3.500
270
0.700
440
4.000
275
0.750
445
4.500
280
0.800
7 TERMINAL2
13
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
5
Screw 10-32 (Bus Type)
8 ACTUATOR COLOR & LEGEND
I-O
ON-OFF Dual
White A
B
1
Black C
D
2
Red
F
G
3
Green H
J
4
Blue
K
L
5
Yellow M
N
6
Gray
P
Q
7
Orange R
S
8
9 MOUNTING/BARRIERS
MOUNTING STYLE
Threaded Insert, 2 per pole
A
6-32 X 0.195 inches
B
ISO M3 x 5mm
9
Mounting/
Barriers
10
Trip Level
712
613
614
615
616
617
618
620
622
624
625
630
11
Agency
Approval
450
455
460
465
470
475
480
485
490
495
610
710
611
711
612
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
B
C
E
H
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M4 (Bus Type)
Screw M5 (Bus Type)
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
Legend Color
Black
White
White
White
White
Black
Black
Black
BARRIERS
yes
yes
10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT
A
5 mA (Class A GFCI)4,5,6
E
30 mA (ELCB)
11 AGENCY APPROVAL3
G
UL489 Listed, CSA Certified
C
UL1077
I
UL1077, UL1500 7
NOTES:
Other time delay values available, consult factory.
Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of
rated current and greater within the time limit shown in this curve.
Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current
and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wallmount position.
The minimum inrush pulse tolerance handling capability is 12 times the rated
current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.
4
www.carlingtech.com
PB-Series – Dimensional Specifications
INDICATE "ON"
1.515 MAX
[38.48]
3.03
[76.9]
INDICATE
"OFF"
AND
SINGLE
COLOR
LINE
.21
[5.3]
1.25
[31.6]
TEST
LOAD
2.17
[55.0]
LOAD
1-POLE 120 VAC VERSION
TEST
LINE
#6-32/M3 MOUNTING INSERTS
1.88
[47.8]
LINE TERMINAL
2.265 MAX
[57.53]
1.660
[42.16]
2.58
[65.6]
TEST
2.37
[60.2]
.375
[9.53]
.39
[9.9]
CURRENT TRANSFORMERS
LOAD TERMINAL
+.020
1.500
-.000
+.50
38.10
-.00
[
.750 TYP
[19.05]
1.260
[32.00]
GFCI NEUTRAL WIRE
2-POLE 120/240 VAC VERSION
]
1.660
[42.16]
.20
[5.1]
+.020
2.250
-.000
+.50
57.15
-.00
[
Ø .156 TYP
[3.96]
]
PANEL CUTOUT
NEUTRAL BREAK POLE
3.015 MAX
[76.58]
.750 TYP
[19.05]
TEST
2-POLE 120/240 VAC WITH NEUTRAL BREAK
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
5
PB-Series – Dimensional Specifications
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
Time Delay Curves
6
Instantaneous
Medium
Short
Long
www.carlingtech.com
PB-Series – Wiring Diagrams
120VAC with Switched Neutral
SYSTEM NEUTRAL
120VAC without Switched Neutral
SYSTEM NEUTRAL
GFCI
MODULE
PIGTAIL
GFCI
MODULE
PIGTAIL
LOAD
NEUTRAL
LOAD
HOT
LOAD
HOT
LINE/SOURCE
(HOT)
LINE/SYSTEM
NEUTRAL
LINE/SOURCE
(HOT)
120 VAC
LOAD
120 VAC
LOAD
AC SOURCE
AC SOURCE
120/240VAC without Switched Neutral
120/240VAC with Switched Neutral
SYSTEM
NEUTRAL
SYSTEM
NEUTRAL
GFCI
MODULE
PIGTAIL
GFCI
MODULE
PIGTAIL
LOAD
HOT
1
LINE/SOURCE 1
120 VAC
LOAD
120 VAC
LOAD
LOAD
HOT
2
LINE/
SOURCE
2
240 VAC LOAD
LOAD
NEUTRAL
LOAD
HOT
1
LINE/SYSTEM
NEUTRAL
120 VAC
LOAD
120 VAC
LOAD
LINE/SOURCE
(1)
LOAD
HOT
(2)
LINE/
SOURCE
(2)
240 VAC LOAD
AC SOURCE
AC SOURCE
www.carlingtech.com
7
PD-Series – General Specifications
SmartGuard® PD-Series
Innovative Features
These precision mechanisms are temperature stable and are
not adversely affected by temperature changes in their operating environment. As such, derating considerations due to
temperature variations are not normally required, and heatinduced nuisance tripping is avoided.
•
•
•
•
Overload, short circuit and equipment ground fault protection in
a single package!
Todayʼs high tech equipment demands high tech protection.
Our SmartGuard Equipment Leakage Circuit Breaker (ELCB)
provides that protection, in one attractive, space-saving package.
SmartGuard is an equipment ground fault protection device that
functions as a standard high-quality Carling hydraulic/magnetic
circuit breaker, offering customized overload and short circuit
protection. In addition, this breaker senses and guards against
faults to ground using a state of the art integrated circuit developed by Carling. This new technology detects faults and when
a fault occurs, the breaker trips and an LED illuminates. The
LED gives a clear indication that the trip occurred as a result of
leakage. This protection helps prevent serious equipment damage and fire.
•
•
•
•
•
•
Overload, short circuit and ground fault protection in a
single package
Handle style actuators with optional “handleguard”
Wiping Contacts - Mechanical linkage with two-step
actuation – cleans contacts, provides high, positive
contact pressure & longer contact life
A trip-free mechanism, a safety feature, makes it
impossible to manually hold the contacts closed during
overload or fault conditions.
A common trip linkage between all poles, another safety
feature, ensures that an overload in one pole will trip all
adjacent poles.
Front panel or DIN rail mounting options
“State of the art” integrated circuit developed by Carling
Equipment leakage sensitivity from 10 to 100 milliamps
Integral push-to-test button and LED “tripped” indicator
Immediate reset after fault has been cleared
Agency Certifications
UL Recognized
UL Standard 1077
UL Standard 943
Component Recognition Program as Equipment Leakage Circuit Interrupter and, Protectors,
Supplementary (FTTJ2, File E177510).
Tested as Ground Fault Circuit Interrupters for Equipment Protection.
CSA Certified
Component Equipment Leakage Current Interrupter with Supplementary Protector, under Class
C22.2,No. 144-M91, FIle LR47848-50
TUV Certified
IEC 947-2 and appendix B: Circuit Breakers incorporating Residual Current Protection. Complies with
waveform requirements of IEC 1008-1, Type A.
8
www.carlingtech.com
PD-Series – General Specifications
Electrical
Table A: Lists UL Recognized & CSA
Certified configurations and performance
capabilities as a Component
Supplementary Protector.
PD-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER
VOLTAGE
CIRCUIT
CONFIGURATION
MAX RATING
VOLTS
120/208
120/208
SERIES
208-240
480Y
Table B: Lists TUV Certified
configurations and performance capabilities as a Circuit
breaker incorporating residual
current protection.
Electrical
Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz
Standard Current Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0,
20.0, 25.0, 30.0, 35.0, 40.0 & 50.0
amps. For other ratings, consult factory.
Insulation Resistance
Minimum of 100 Megohms @ 500
VDC.
Dielectric Strength
1960 VAC, 60 Hz for one minute
between all electrically isolated terminals.
Resistance, Impedance
from Line to Load Terminal
(Values Based on Series Trip Circuit
RESISTANCE, IMPEDANCE VALUES
Breaker)
FREQUENCY
CURRENT RATING
FULL
3
1
1-50
50/60
3
3
Mechanical
Endurance
Trip Free
Trip Indication:
from Line to Load Terminals
Physical
20.1 - 50.0
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
Multiple of
Rated Current
Ir
Time Delay Curves
22, 24, 26
12x
4.165
8.33
Pulse Tolerance Curve
16.67
t
Time in
Milliseconds
Leakage To Ground
Standard Must Trip
Leakage Current Ratings
Trip Time
Test Button
Leakage Trip Indicator
www.carlingtech.com
7, 10, 15, 30, 50 & 100 milliamps.
For other ratings, consult factory.
300 ms Max. @ 100%, 40ms Max.
@ 500% of must trip leakage current.
On breaker face above actuator.
Red LED on breaker face above
actuator.
BACKUP FUSE
(MILLIAMPS)
---
5000
---
50/60
50/60
AMPS
1-50
AMPS
1
MUST - TRIP
PURPOSE
PHASE
1-50
1-30
LEAKAGE
CURRENT
UL / CSA
LOAD
HERTZ
50/60
GENERAL
INTERRUPTING
CAPACITY (AMPS)
---
30.1-50
WITHOUT
5000
2000
2000
RATING
7-100
7-100
7-100
7-100
10,000 ON-OFF operations @ 6 per
minute; with rated current and voltage.
All SmartGuard equipment leakeage
circuit breakers will trip on overload
or leakage to ground, even when
actuator is forcibly held in the ON
position.
The actuator moves to the OFF
position when an overload or earth
leakage ground fault causes the
breaker to trip. The LED is illuminated when leakage to ground causes
the circuit breaker to trip.
Number of Poles
2, 3 & 4
Length (included switched
or unswitched neutral)
4.2 inches ( 106.7 mm)
Width
2-pole: 3.0 inches (76.2 mm)
3-pole: 3.75 inches (95.3 mm)
4-pole: 4.5 inches (114.3 mm)
Depth
2.5inches (63.5mm).
Weight: 2-pole
16.0 oz. (453.6 gm)
3-pole: 21.4 oz. (606.7 gm)
4-pole: 26.9 oz. (762.6 gm)
Standard Colors
Housing - gray;
Actuator - black, red, or white
Mounting
Front Panel or Standard 35mm
Symmetrical DIN Rail (35 x 7.5 or 35
x 15mm per DIN EN5002).
Termination
Box Lug
Environmental
Operating Temperature
+10°C to +50°C
9
PD R – B – 24 – 650 – B – 2 A 1 – 1 – C
PD-Series – Ordering Scheme
1
Series
1 SERIES
PD
2
Voltage/
Poles
3
Circuit
2 SYSTEM VOLTAGE/POLES1
System Voltage
A
120VAC 1Ø
B
120/240 VAC 1Ø
C
120/208 VAC 1Ø,
120/240 VAC 1Ø
D
120/208 VAC 1Ø,
120/240 VAC 1Ø
E
208/240 VAC 3Ø
F
208/240 VAC 3Ø
G
208/240 VAC 3Ø
P
480Y VAC 3Ø
Q
480Y VAC 3Ø
R
480Y VAC 3Ø
3 CIRCUIT
B
Series Trip (Current)
4 FREQUENCY & DELAY
20
50/60Hz Instantaneous
22
50/60Hz Short
5 CURRENT RATING (AMPERES)
410
1.000
445
4.500
512
1.250
450
5.000
415
1.500
455
5.500
517
1.750
460
6.000
420
2.000
465
6.500
522
2.250
470
7.000
425
2.500
475
7.500
527
2.750
480
8.000
430
3.000
485
8.500
435
3.500
490
9.000
440
4.000
495
9.500
Time Delay Curves
4
Frequency
& Delay
5
Current Rating
9 ACTUATOR COLOR & LEGEND4
Actuator
Marking:
Color
Color:
I-O
ON-OFF Dual
White
A
B
1
Black
C
D
2
Red
E
F
3
10 MOUNTING3
1
Threaded Insert 6-32 x 0.195 inches
2
Threaded Insert ISO M3 x 6.5 mm
50/60Hz Medium
50/60Hz Long
717
618
619
620
622
624
625
630
635
640
650
10
Mounting
11
Agency
Approval
17.500
18.000
19.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
50.000
Marking Color:
Black
White
White
11 AGENCY APPROVAL
C
UL Recognized & CSA Certified
U
TUV Certified
Notes:
1
Units with a switched or unswitched neutral connection are the same size as a unit with
an additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is
the same physical size as a 3-pole unit.)
Switched neutral poles contain the same overcurrent protection as the other poles.
2
The leakage currents shown will cause the breaker to trip (must-trip current). The musthold current is 67% of the must-trip current.
3
All breakers are front panel mountable using screw size shown. Breakers may also be
mounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail.
4
TUV certifed units must have I-O or Dual legends.
Instantaneous
Medium
Short
Long
10
9
Actuator
Color
8 ACTUATOR
A
Handle
B
Handle. with handleguard
Three
Three plus unswitched neutral
Three plus switched neutral
Three
Three plus unswitched neutral
Three plus switched neutral
10.000
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
8
Actuator
7 TERMINAL
2
Front Connected Box Lug
Two plus switched neutral
610
710
611
711
612
712
613
614
615
616
617
7
Terminal
6 EQUIPMENT LEAKAGE - TRIP CURRENT (milliamps)2
B
7
D
15
F
50
C
10
E
30
G
100
Poles
One plus unswitched neutral
Two
Two plus unswitched neutral
24
26
6
Equipment
Leakage Trip Current
www.carlingtech.com
PD-Series – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
NOTES:
Other time delay values available, consult factory.
Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of
rated current and greater within the time limit shown in this curve.
Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current
and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wallmount position.
The minimum inrush pulse tolerance handling capability is 12 times the rated
current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.
www.carlingtech.com
11
PD-Series – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
12
www.carlingtech.com
carlingtech.com
Our extensive web site provides in-depth,
detailed information about our products
and capabilities. And with offices around
the world, weʼre always ready to do business,
answer questions and help our customers.
Call, fax or e-mail anytime to start working
with a company thatʼs always ON.
World-Wide
Corporate Headquarters
Carling Technologies, Inc.
60 Johnson Avenue
Plainville, CT 06062
860/793-9281
FAX: 860/793-9231
E-mail: [email protected]
www.carlingtech.com
Warranty Policy
Carling Technologies
Europe/Middle East/Africa
Carling Technologies Ltd.
Devon, England
Int + 44 (0)1392-364422
FAX: Int + 44 (0)1392-364477
E-mail: [email protected]
Carling Technologies
Asia/Pacific
Carling Technologies Asia-Pacific Ltd.
Kowloon, Hong Kong
Int + 852-2737-2277
FAX: Int + 852-2736-9332
E-mail: [email protected]
Additional Carling Technologies Offices
East Region Sales Office, CT
[email protected]
Midwest Region Sales Office, IL
[email protected]
West Region Sales Office, CA
[email protected]
GmbH, Germany
[email protected]
SARL, France,
[email protected]
Asia-Pacific Ltd., Shanghai, China
[email protected]
Asia-Pacific Ltd., Japan
[email protected]
Pune, India
[email protected]
Kaohsiung, Taiwan
[email protected]
Carling Technologies, Inc. (Seller) warrants that goods sold hereunder shall be free of defects in material and workmanship for one year from date of shipment. In the event of such defects, the Sellerʼs only obligation shall be the
replacement or the cost of the defective goods, themselves, excluding, without limitation, labor costs, which are or may be required in connection with the replacement or reinstallation of the goods. This warranty is the Sellerʼs
sole obligation and excludes all other remedies or warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. This
Warranty expressly excludes any and all incidental, special and/or consequential damages of any nature. Seller further disclaims any responsibility for injury to person or damage to or loss of property or value caused by any product which has been subjected to misuse, negligence, or accident; or misapplied, or modified or repaired by a person or persons not authorized by the Seller or which have been improperly installed.
www.carlingtech.com
GFCI4_08_a
www.carlingtech.com