TRG70A Series

EXTERNAL POWER SUPPLY
TRG70A Series
7 0 W AT T S - A C / D C G E N E R A L S I N G L E O U T P U T
FEATURES
•
•
•
•
•
•
•
•
Wide input voltage
Continuous short circuit protection
Over voltage protection
Output voltage available from 12VDC to 48VDC
High efficiency 87% typical
Meets EN55022 Class ”B”, conducted emissions
MEPS compliance, Efficiency Mark V
ROHS compliance
SPECIFICATIONS
INPUT
STANDARDS AND APPROVALS
Voltage range
90 to 264Vac
Frequency
50Hz to 60Hz
Inrush current
60A max @ 240Vac
Isolation
Input to Output 4,242Vac
Leakage current
3.5mA max.
OUTPUT
Output voltage
Factory preset, see table (not adjustable)
Voltage set-point
+/-2% (60% load)
Ripple and noise
1% p-p max
Short circuit protection
Continuous (Auto recovery)
Over voltage protection
Yes
Hold-up time
Load regulation
8ms typ @ 115Vac
+/-2 to +/-5% (20% to 100% load)
Model dependent
+/-1% max 100Vac to 240Vac at full load
Line regulation
Storage temperature
0°C to +60°C
Derate from 100% at 40°C linearly to 50% at
60°C
-20°C to +85°C
TECHNICAL ILLUSTRATION
286
Queensland Electrical Safety Office
Certificate of approval Qld Q080453,
AS/NZS 609050.1:2003, EN60950
C-tick
AS/NZS CISPR 11:2002 Group 1
EMI standards
Meets EN55022 Class B and CISPR/FCC Class B
RCM
Complies with AS/NZS 4417 Parts 1,2,3 N911
MECHANICAL
Dimensions
132 x 58 x 30.5mm
Weight
345g
AC Inlet
IEC320/C14
Output connector
Right angle, hollow barrel connector, 2.5mm
inside diameter; 5.5mm outside diameter;
9.5mm length Center positive polarity.
DC cord length
720mm with ferrite core 18AWG/UL1185
SELECTION TABLE
Consult Powerbox for variation of output connector and DC cord length
ENVIRONMENTAL
Operating temperature
Load derating
Safety standards
RATED
VNOM
OUTPUT
CURRENT
MAX
POWER
TRG70A120- 21E11-V
12Vdc
5.5A
66W
TRG70A150- 21E11-V
15Vdc
4.6A
69W
TRG70A180- 21E11-V
18Vdc
3.9A
70W
TRG70A190- 21E11-V
19Vdc
3.7A
70W
TRG70A240- 21E11-V
24Vdc
3.0A
72W
TRG70A480- 21E11-V
48Vdc
1.5A
72W
MODEL NUMBER
Doc. No. PBC9 Rev.C 28-4-11