DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-DA0287-277(S) (6,5W DUAL OUTPUTS WITH DIMMING FUNCTION)
DESCRIPTION :
This DC/AC Inverter is developed and optimized for
NEC Display: NL6448BC20-18D
APPLICABLE LCD:
6.5 inches dual lamps
Lamp voltage 430 Vrms
Lamp current 4.0 mArms for two CCFL
Lamp start up voltage 960 Vrms (Vin: 5 Vdc)
FEATURES :
Current feedback circuit
High efficiency
Low noise with voltage resonant circuit
Regulated output current
Brightness 122 cd/m² @ 4,0 mArms current for two CCFL
Mechanically compatible to NEC inverter 65PW061
Pinning compatible to 65PWB31
Max. input cap. 30µF
Input current max. 520 mA @ 4,5 Vdc
Inrush current max. 850mA @ 4,5Vdc with Load: 160KΩ each output
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating temperature range
Storage temperature range
Humidity
DIMENSIONS :
-10°C ~ +70°C
-20°C ~ +85°C
95 %RH max
LxWxH
113 x 25 x 10
Unit : mm
Weight :22 (g) typ.
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
IL-Z-6PL-SMTYE
SM03(7-D1)B-BHS-1-TB
Note
t=1.6mm
JAE
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.8, 19th May 2014
DC-AC INVERTER UNIT
PS-DA0287-277(S) (6,5W DUAL OUTPUTS WITH DIMMING FUNCTION)
Input side CN1:
Pin No.
CN 1-1+2
CN 1-3+4
CN 1-5
CN 1-6
Symbols
GND
VIN
BRTL
BRTH
Output side CN2 (SM03(7-D1)B-BHSS-1-TB)
Pin No.
Symbols
Ratings
VBLH
430 Vrms (1.88mArms)
CN 2-1
VBLH
430 Vrms (1.88mArms)
CN 2-2
N. C.
CN 2-3
VBLC
(GND)
CN 2-4
Ratings
4.5~ 5.5 Vdc
0~2.5 Vdc / 0~10 kΏ
GND / 0~10 kΏ
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Note 2 :
Note 3 :
Note 4 :
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
4,5~5.5
4,5~5.5
4,5~5.5
4,5~5.5
4,5~5.5
4,5~5.5
2.5
0.0
2.5
2.5
2.5
2.5
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
3.5
1.6
45.5
960
-
4.0
1.8
53.0
1.100
1.0
4.5
2.0
0.52
60.5
1.300
-
Unit
Note
mArms
mArms
Adc
kHz
Vrms
sec
Not e 4
Not e 2
wit hout load
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
Dimming range 30% - 100% ≙ 0R ~ 10k; 10k = 100% brightness.
Please provide Vcc before applying any control signals into inverter.
Revere the sequence during power off which is control signal off first then Vcc.
Common current for both CCFL.
TEST CIRCUIT :
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)