FDC10 FDC10W SERIES DC-DC CONVERTER 2:1 & 4:1 WIDE INPUT RANGE UP TO 10 WATTS FEATURES APPLICATIONS • NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION • STANDARD 2.00 X 1.00 X 0.40 INCH • SIX-SIDED CONTINUOUS SHIELD • UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL OCP SCP • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT OVP TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25ºC otherwise noted Model Number FDC10-12S33 FDC10-12S05 FDC10-12S12 FDC10-12S15 FDC10-12D05 FDC10-12D12 FDC10-12D15 FDC10-24S33 FDC10-24S05 FDC10-24S12 FDC10-24S15 FDC10-24D05 FDC10-24D12 FDC10-24D15 FDC10-48S33 FDC10-48S05 FDC10-48S12 FDC10-48S15 FDC10-48D05 FDC10-48D12 FDC10-48D15 1 Input Range Output Voltage Output Current @ Full Load Input Current @ No Load Efficiency Maximum Capacitor Load (1) VDC 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 VDC 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 mA 2000 2000 830 670 ±1000 ±416 ±333 2000 2000 830 670 ±1000 ±416 ±333 2000 2000 830 670 ±1000 ±416 ±333 mA 17 21 38 36 39 47 45 15 22 18 36 28 24 31 11 14 14 10 16 19 16 % 80 81 84 84 84 83 84 80 82 84 84 83 85 84 80 84 86 87 84 86 85 µF 6800 4700 690 470 ±680 ±330 ±110 6800 4700 690 470 ±680 ±330 ±110 6800 4700 690 470 ±680 ±330 ±110 www.PDUKE.com 2015/2/26 Model Number Input Range Output Voltage VDC 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 VDC 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 FDC10-24S33W FDC10-24S05W FDC10-24S12W FDC10-24S15W FDC10-24D05W FDC10-24D12W FDC10-24D15W FDC10-48S33W FDC10-48S05W FDC10-48S12W FDC10-48S15W FDC10-48D05W FDC10-48D12W FDC10-48D15W Output Current @ Full Load mA 2500 2000 830 670 416 ±1000 ±416 ±333 2500 2000 830 670 416 ±1000 Input Current @ No Load mA 13 11 16 26 15 15 22 10 9 9 11 12 20 20 Maximum Capacitor Load (1) µF 6800 4700 690 470 ±680 ±330 ±110 6800 4700 690 470 ±680 ±330 ±110 Efficiency % 78 80 84 81 82 80 80 76 81 84 84 82 78 81 PART NUMBER STRUCTURE FDC10 - 48 Series name Input Voltage (VDC) 12: 9~18 24: 18~36 48: 36~75 S 05 Output Quantity Output Voltage (VDC) S: Single 33: 05: 12: 15: 05: 12: 15: D: Dual FDC10 Series name 3.3 5 12 15 S 05 Input Voltage (VDC) Output Quantity Output Voltage (VDC) S: Single D: Dual 33: 05: 12: 15: 3.3 5 12 15 P HS Version Code Remote On/Off Option Assembly Option : Standard Version M1: M1 Version M2: M2 Version W Input Range 4:1 HS Remote On/Off Option Assembly Option P: Positive logic N: Negative logic Constant resistive load 100 ms, max. Power up 12Vin(nom) 24Vin(nom) 48Vin(nom) Input filter Remote ON/OFF (Option) Referred to –Vin pin Positive logic 2 : No Assembly Option HS: Heat-sink HC: Heat-sink with Clamp 12Vin(nom) 24Vin(nom) 48Vin(nom) 24Vin(nom) 48Vin(nom) Input reflected ripple current Start up time Input surge voltage Voltage accuracy Line regulation : No Assembly Option HS: Heat-sink HC: Heat-sink with Clamp P Conditions FDC10 series FDC10W series OUTPUT SPECIFICATIONS Parameter P: Positive logic N: Negative logic 05: ±5 12: ±12 15: ±15 INPUT SPECIFICATIONS Parameter Operating input voltage range M1 ±5 ±12 ±15 48 24: 9~36 48: 18~75 - DC-DC ON DC-DC OFF Negative logic DC-DC ON DC-DC OFF Input current of Ctrl pin Remote off input current Conditions Low Line to High Line at Full Load www.PDUKE.com Min. Typ. Max. 9 18 36 9 18 12 24 48 24 48 30 20 18 36 75 36 75 -0.5 Min. -1.0 -0.2 Unit VDC VDC mAp-p ms 36 VDC 50 100 Pi type Open or 3.5 ~ 12VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3.5 ~ 12VDC +1.0 mA 20 mA Typ. Max. Unit +1.0 +0.2 % % 2015/2/26 Load regulation No Load to Full Load Cross regulation Ripple and noise Asymmetrical load 25%/100% FL Measured by 20MHz bandwidth Temperature coefficient Transient response recovery time Over voltage protection 25% load step change Zener diode clamp Isolation voltage 1 minute Isolation resistance Isolation capacitance Switching frequency Safety approvals 500VDC 3.3Vout 5Vout 12Vout 15Vout % %/ºC µs VDC 150 % Continuous, automatics recovery Conditions Min. Input to Output Input (Output) to Case 1600 1600 1 MIL-HDBK-217F, Full load Conditions Standard M1 (2) M2, W series Min. With derating Without derating With derating Typ. Without heat-sink With heat-sink Unit VDC GΩ pF 300 kHz UL60950-1 EN60950-1 IEC60950-1 Nickel-coated copper Non-conductive black plastic Epoxy (UL94 V-0) 27g (0.95oz) 3.342 x 106 hrs 300 330 Typ. -25 -40 -40 Max. +85 +85 +85 +105 +125 -55 Vertical direction by natural convection (20LFM) Max. 12 10 Unit ºC ºC ºC/W Thermal shock Vibration Relative humidity MIL-STD-810F MIL-STD-810F 5% to 95% RH EMC SPECIFICATIONS Parameter EMI (3) ESD Radiated immunity Fast transient (4) Surge (4) Conducted immunity % mVp-p +0.02 250 3.9 6.2 15 18 270 ENVIRONMENTAL SPECIFICATIONS Parameter Maximum case temperature Storage temperature range Thermal impedance +0.5 +1.0 +5.0 50 75 % of Iout rated GENERAL SPECIFICATIONS Parameter Operating ambient temperature -0.5 -1.0 -5.0 -0.02 Over load protection Short circuit protection Case material Base material Potting material Weight MTBF Single Dual Dual Single Dual Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Air ± 8kV and Contact ± 6kV 10 V/m ± 2kV ± 2kV 10 Vr.m.s Level Class B Perf. Criteria B Perf. Criteria A Perf. Criteria B Perf. Criteria B Perf. Criteria A Note: 1. 2. 3. 4. Test by minimum input and constant resistive load. M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard and M2 version. The standard modules meet EN55022 Class A and Class B with external components. For further information, please contact with P-DUKE. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V. CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE 3 www.PDUKE.com 2015/2/26 FDC10-48S05 Derating Curve FDC10-48S05 Derating Curve With Heat-sink FDC10-48S05 Efficiency vs. Input Voltage FDC10-48S05 Efficiency vs. Output Load MECHANICAL DRAWING PIN CONNECTION PIN 1 2 3 4 5 6 SINGLE +Vin -Vin +Vout No pin -Vout Ctrl(Option) DUAL +Vin -Vin +Vout Common -Vout Ctrl(Option) 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) 4 www.PDUKE.com 2015/2/26