COA

ELECTRICAL RATING:
Input (dc)
Model
V
mA
FKC05-12S33- z1z1z1z1z1z1
FKC05-12S05- z1z1z1z1z1z1
FKC05-12S12- z1z1z1z1z1z1
FKC05-12S15- z1z1z1z1z1z1
FKC05-12D05- z1z1z1z1z1z1
FKC05-12D12- z1z1z1z1z1z1
FKC05-12D15- z1z1z1z1z1z1
FKC05-24S33- z1z1z1z1z1z1
FKC05-24S05- z1z1z1z1z1z1
FKC05-24S12- z1z1z1z1z1z1
FKC05-24S15- z1z1z1z1z1z1
FKC05-24S33W- z1z1z1z1z1z1
FKC05-24S05W- z1z1z1z1z1z1
FKC05-24S12W- z1z1z1z1z1z1
FKC05-24S15W- z1z1z1z1z1z1
FKC05-24D05- z1z1z1z1z1z1
FKC05-24D12- z1z1z1z1z1z1
FKC05-24D15- z1z1z1z1z1z1
FKC05-24D05W- z1z1z1z1z1z1
FKC05-24D12W- z1z1z1z1z1z1
FKC05-24D15W- z1z1z1z1z1z1
FKC05-48S33- z1z1z1z1z1z1
FKC05-48S05- z1z1z1z1z1z1
FKC05-48S12- z1z1z1z1z1z1
FKC05-48S15- z1z1z1z1z1z1
FKC05-48S33W- z1z1z1z1z1z1
FKC05-48S05W- z1z1z1z1z1z1
FKC05-48S12W- z1z1z1z1z1z1
FKC05-48S15W- z1z1z1z1z1z1
FKC05-48D05- z1z1z1z1z1z1
FKC05-48D12- z1z1z1z1z1z1
FKC05-48D15- z1z1z1z1z1z1
FKC05-48D05W- z1z1z1z1z1z1
FKC05-48D12W- z1z1z1z1z1z1
FKC05-48D12W-Bz1z1z1z1z1z1
FKC05-48D15W- z1z1z1z1z1z1
9~18 or 12
9~18 or 12
9~18 or 12
9~18 or 12
9~18 or 12
9~18 or 12
9~18 or 12
18~36 or 24
18~36 or 24
18~36 or 24
18~36 or 24
9~36 or 24
9~36 or 24
9~36 or 24
9~36 or 24
18~36 or 24
18~36 or 24
18~36 or 24
9~36 or 24
9~36 or 24
9~36 or 24
36~75 or 48
36~75 or 48
36~75 or 48
36~75 or 48
18~75 or 48
18~75 or 48
18~75 or 48
18~75 or 48
36~75 or 48
36~75 or 48
36~75 or 48
18~75 or 48
18~75 or 48
18~75 or 48
18~75 or 48
539
793
847
912
793
839
833
274
401
428
457
539
804
870
926
385
404
433
795
829
854
139
201
212
227
283
409
436
470
198
207
217
409
429
429
448
V
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
3.3
5
12
15
±5
±12
±15
±5
±12
±15
3.3
5
12
15
3.3
5
12
15
±5
±12
±15
±5
±12
±12
±15
Output(dc)
mA
1000
1000
470
400
±500
±230
±190
1000
1000
470
400
1000
1000
470
400
±500
±230
±190
±500
±230
±190
1000
1000
470
400
1000
1000
470
400
±500
±230
±190
±500
±230
±250
±190
File E193009
Vol. 2
Sec. 5
and Report
Page 5
Issued:
Revised:
2002-01-17
2013-03-05
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
Use - For use only in complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
Special Considerations - The following items are considerations that were used when
evaluating this product.
*USR/CNR indicates investigation to the U.S. and Canadian (Bi-National) Standard for Safety
of Information Technology Equipment, UL 60950-1, 2nd Edition, 2011-12-19 (Information
Technology Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety
- Part 1: General Requirements).
The component was submitted and tested for a maximum manufacturer’s recommended
ambient (Tma) of 55°C.
Conditions of Acceptability - When installed in the end-product, consideration shall be given
to the following:
*1.
This component has been judged on the basis of required spacing in the Standard for Safety
of Information Technology Equipment, UL 60950-1, 2nd Edition, 2011-12-19
(Information Technology Equipment - Safety - Part 1: General Requirements) CSA
C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment Safety - Part 1: General Requirements), which would cover the component itself if
submitted for Listing.
2.
The products were tested on a 6.3A time delay fuse protection circuit. If used on a
protection circuit greater than this, additional testing may be necessary.
3.
All secondary output circuits are SELV and are not hazardous energy levels.
4.
5.
6.
The terminals and connectors are suitable for factory wiring only.
The equipment has been evaluated for use in a Pollution Degree 2 environment.
A suitable Electrical and Fire enclosure shall be provided.
7.
The component is intended to be connected to isolated secondary circuit which is separated
from primary circuit by Reinforced or Double insulation.
8.
PWB shall not exceed 105°C during heating test end-product installation.
9.
The product was investigated for functional insulation and complies with 2.2.4 under single
fault conditions.