ELECTRICAL RATING: Input (dc) Model V mA FKC05-12S33- z1z1z1z1z1z1 FKC05-12S05- z1z1z1z1z1z1 FKC05-12S12- z1z1z1z1z1z1 FKC05-12S15- z1z1z1z1z1z1 FKC05-12D05- z1z1z1z1z1z1 FKC05-12D12- z1z1z1z1z1z1 FKC05-12D15- z1z1z1z1z1z1 FKC05-24S33- z1z1z1z1z1z1 FKC05-24S05- z1z1z1z1z1z1 FKC05-24S12- z1z1z1z1z1z1 FKC05-24S15- z1z1z1z1z1z1 FKC05-24S33W- z1z1z1z1z1z1 FKC05-24S05W- z1z1z1z1z1z1 FKC05-24S12W- z1z1z1z1z1z1 FKC05-24S15W- z1z1z1z1z1z1 FKC05-24D05- z1z1z1z1z1z1 FKC05-24D12- z1z1z1z1z1z1 FKC05-24D15- z1z1z1z1z1z1 FKC05-24D05W- z1z1z1z1z1z1 FKC05-24D12W- z1z1z1z1z1z1 FKC05-24D15W- z1z1z1z1z1z1 FKC05-48S33- z1z1z1z1z1z1 FKC05-48S05- z1z1z1z1z1z1 FKC05-48S12- z1z1z1z1z1z1 FKC05-48S15- z1z1z1z1z1z1 FKC05-48S33W- z1z1z1z1z1z1 FKC05-48S05W- z1z1z1z1z1z1 FKC05-48S12W- z1z1z1z1z1z1 FKC05-48S15W- z1z1z1z1z1z1 FKC05-48D05- z1z1z1z1z1z1 FKC05-48D12- z1z1z1z1z1z1 FKC05-48D15- z1z1z1z1z1z1 FKC05-48D05W- z1z1z1z1z1z1 FKC05-48D12W- z1z1z1z1z1z1 FKC05-48D12W-Bz1z1z1z1z1z1 FKC05-48D15W- z1z1z1z1z1z1 9~18 or 12 9~18 or 12 9~18 or 12 9~18 or 12 9~18 or 12 9~18 or 12 9~18 or 12 18~36 or 24 18~36 or 24 18~36 or 24 18~36 or 24 9~36 or 24 9~36 or 24 9~36 or 24 9~36 or 24 18~36 or 24 18~36 or 24 18~36 or 24 9~36 or 24 9~36 or 24 9~36 or 24 36~75 or 48 36~75 or 48 36~75 or 48 36~75 or 48 18~75 or 48 18~75 or 48 18~75 or 48 18~75 or 48 36~75 or 48 36~75 or 48 36~75 or 48 18~75 or 48 18~75 or 48 18~75 or 48 18~75 or 48 539 793 847 912 793 839 833 274 401 428 457 539 804 870 926 385 404 433 795 829 854 139 201 212 227 283 409 436 470 198 207 217 409 429 429 448 V 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 3.3 5 12 15 ±5 ±12 ±15 ±5 ±12 ±15 3.3 5 12 15 3.3 5 12 15 ±5 ±12 ±15 ±5 ±12 ±12 ±15 Output(dc) mA 1000 1000 470 400 ±500 ±230 ±190 1000 1000 470 400 1000 1000 470 400 ±500 ±230 ±190 ±500 ±230 ±190 1000 1000 470 400 1000 1000 470 400 ±500 ±230 ±190 ±500 ±230 ±250 ±190 File E193009 Vol. 2 Sec. 5 and Report Page 5 Issued: Revised: 2002-01-17 2013-03-05 ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): Use - For use only in complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. Special Considerations - The following items are considerations that were used when evaluating this product. *USR/CNR indicates investigation to the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements). The component was submitted and tested for a maximum manufacturer’s recommended ambient (Tma) of 55°C. Conditions of Acceptability - When installed in the end-product, consideration shall be given to the following: *1. This component has been judged on the basis of required spacing in the Standard for Safety of Information Technology Equipment, UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment Safety - Part 1: General Requirements), which would cover the component itself if submitted for Listing. 2. The products were tested on a 6.3A time delay fuse protection circuit. If used on a protection circuit greater than this, additional testing may be necessary. 3. All secondary output circuits are SELV and are not hazardous energy levels. 4. 5. 6. The terminals and connectors are suitable for factory wiring only. The equipment has been evaluated for use in a Pollution Degree 2 environment. A suitable Electrical and Fire enclosure shall be provided. 7. The component is intended to be connected to isolated secondary circuit which is separated from primary circuit by Reinforced or Double insulation. 8. PWB shall not exceed 105°C during heating test end-product installation. 9. The product was investigated for functional insulation and complies with 2.2.4 under single fault conditions.