2.0 kW Compact Pulse Amplifier for Test and Measurement Applications 8 to 1 8 GHz The VZM-3529J1 2000 Watt TWT Compact Medium Power Pulsed Amplifier 230 VAC operation. Designed to meet Inteernational Safety Standard EN61010 and Electromagnetic Compatibility EMC 2004/108/EC. Versatile Ultra-wideband, automatic fault recycle, userfriendly microprocessor-controlled logic with integrated computer interface, digital metering, electronic variable attenuation , soft fail when subjected to extreme load SWR conditions, and quiet operation suitable for laboratory environments. Easy to Maintain Modular design and built-in fault diagnostic capability backed by CPI’s worldwide 24-hour customer support network that includes over twenty regional factory service centers. An integral solid state preamplifier and IEEE interface are included as standard features. Communications & Power Industries Canada, Inc. 45 River Drive Georgetown, Ontario CANADA L7G2J4 tel: +1 (905) 877-0161 fax: +1 (905) 877-5327 e-mail: [email protected] www.cpii.com/satcom 2.0 kW Compact Pulsed Amplifier Global Applications Five rack-units tall (8.75 in/222 mm). 8 to 18 GHz Compact 8 t o 18 G H z SPECIFICATIONS, VZM-3529J1 Environmental Electrical OPTIONS: • Remote Control Panel • Input Isolator (-1 dB Gain) • 115 VAC External Step-up Transformer Frequency 8.0 to 18.0 GHz Ambient Temperature Output Peak Power (min.) TWT Flange -10° to +40°C operating -40° to +70°C non-operating 2200 W 2000 W Relative Humidity 95% non-condensing Altitude 10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 40,000 ft., non-operating Gain 63 dB min. at rated power output; 65 dB min. at small signal RF Level Adjust 0 to 20 dB Shock and Vibration Gain Stability ±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.) As normally encountered in a protected laboratory environment Acoustic Noise 65 dBA @ 3 ft. from amplifier Input VSWR 2.5:1 max; 2.0:1 max. with optional input isolator Output VSWR 2.5:1 typ. Load VSWR Mechanical Cooling (TWT) 1.5:1 max. for full spec. compliance; Any value for continuous operation (soft fail VSWR protection limits at 500 W peak) Forced air with integral blower Rear air intake & exhaust; 0.10" water max. external pressure loss allowable RF Input Connection Type N female Phase Noise 0.5°rms asynchronous ripple RF Output Connection WRD-750 W/G flange Pulse Width 0.07 to 50 µs RF Output Monitor Type N female, -50 dB nominal PRF 50 kHz max, 100 kHz max. available as option Dimensions (W x H x D)* Duty Cycle 4% max. 19 x 8.75 x 26 in. (483 x 223 x 661 mm) Delay 300 ns typ., 400 ns max. Weight 120 lbs (55 kg) max. Droop 0.5 dB over 50 µs Heat Dissipation 700 watts (TBD) Harmonic Content -3 dBc typ. at lower band edge, decreasing to -15 dBc typ. at upper band edge Safety EN61010 NPO -15 dBm/MHz Beam On; -110 dBm/MHz Beam Off Primary Power 220 - 240 VAC ±10%, single phase 47- 63 Hz Power Consumption 2.6 kVA typ. 3.0 kVA max. Filament Voltage Reduction of 10% in standby for extended TWT life (available as option) Inrush Current 200% max. *Dimension exclude front handles, rear fans and exhaust ducts. This product is subject to the U.S. International Traffic in Arms Regulations (ITAR). Sale of this product is subject to US Government approval. In accordance with part 126.1 of the ITAR, it is the policy of the United States to deny licenses and other approvals for the sales, exports/ imports, and or transfer of items subject to the ITAR destined for or originating in certain countries in which the U.S. maintains an arms embargo. Certificate Number: 30515 For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 247, ISSUE 5 DEC 13 PDF