C-Band 4.25 kW Compact Pulsed Amplifier Compact Eight rack-units tall (14 in/356 mm). Versatile Wide band, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, digital metering, and quiet operation suitable for laboratory environments. An integral solid state preamplifier and IEEE interface are included as standard features. Global Applications 230 VAC operation. Designed to meet International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Easy to Maintain Model VZC-3530J1 4.25 kW Compact Pulse Amplifier for Test and Measurement Applications OPTIONS •Remote Control Panel •Input Isolator (-1 dB Gain) Modular design and built-in fault diagnostic capability backed by CPI’s worldwide 24-hour customer support network that includes twenty regional factory service centers. Worldwide Support Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc C-Band Specifications 4.25 kW Compact Pulsed Amplifier Specification Model VZC-3530J1 Frequency 4.0 to 8.0 GHz Output Power (min.), TWT Output Power (min.), Flange Gain 4500 W 4250 W 65 dB min. at rated power (with no RF options); 67 dB min. at small signal (with no RF options); deduct one dB of gain from the above minimums for each RF option Gain Adjustment Range 20 dB min. Gain Stability ±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.) Input VSWR 2.5:1 typ; 1.5:1 typ. with optional input isolator Output VSWR 2.5:1 typ. Load VSWR 1.5:1 max. for full spec. compliance; Peak output pulse power foldback protection at peak reflected power. Will operate without damage or oscillation with any magnitude and phase of source and load impedance. May oscillate with unshielded open due to coupling to input. Should not be tested with connector off. Phase Noise 0.5°rms asynchronous ripple Pulse Width PRF 0.07 to 50 µs 50 kHz max, 100 kHz max. available as option Duty Cycle 6% max. Delay 300 ns typ; 400 ns max. Droop 0.5 dB over 50 µs -10 dBm/MHz Beam On; 110 dBm/MHz Beam Off NPO Primary Power 220 - 240 VAC ±10%, single phase 47- 63 Hz 2.2 kVA typ. 2.5 kVA max. Power Consumption Filament Voltage Reduction of 10% in standby for extended TWT life Inrush Current 200% max. -10° to +40°C operating -40° to +70°C non-operating Ambient Temperature Relative Humidity Altitude Shock and Vibration Cooling 95% non-condensing 10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 40,000 ft., non-operating As normally encountered in a protected laboratory environment Forced air with integral blower Rear air intake & exhaust; 0.10” water max. external pressure oss allowable RF Input Connection Type N female RF Output Connection WRD-350 waveguide flange RF Output Monitor Dimensions (W x H x D) Type N female, -46 dB nominal 19 x 14 x 26 in. (483 x 356 x 661 mm) excluding connectors, fans, handles and exhaust duct Weight 150 lbs (68 kg) max. Heat Dissipation 2200 watts max. Safety EN61010 Acoustic Noise 65 dBA @ 3 ft. from amplifier Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 254, ISSUE 8 dated AUG 2015