VZC-3530J1

C-Band
4.25 kW Compact Pulsed Amplifier
Compact
Eight rack-units tall (14 in/356 mm).
Versatile
Wide band, automatic fault recycle, user-friendly
microprocessor-controlled logic with integrated computer
interface, digital metering, and quiet operation suitable for
laboratory environments.
An integral solid state preamplifier and IEEE interface are
included as standard features.
Global Applications
230 VAC operation. Designed to meet International Safety
Standard EN61010 and Electromagnetic
Compatibility 2004/108/EC.
Easy to Maintain
Model VZC-3530J1
4.25 kW Compact Pulse Amplifier
for Test and Measurement
Applications
OPTIONS
•Remote Control Panel
•Input Isolator (-1 dB Gain)
Modular design and built-in fault diagnostic capability backed
by CPI’s worldwide 24-hour customer support network that
includes twenty regional factory service centers.
Worldwide Support
Backed by over 35 years of satellite communications
experience, and CPI’s worldwide 24-hour customer support
network that includes more than 20 regional factory
service centers.
45 River Drive
Georgetown, Ontario, Canada L7G 2J4
tel:
+1 (905) 702-2228
fax:
+1 (905) 877-5327
e-mail:[email protected]
website:www.cpii.com/emc
C-Band
Specifications 4.25 kW Compact Pulsed Amplifier
Specification
Model VZC-3530J1
Frequency
4.0 to 8.0 GHz
Output Power (min.), TWT
Output Power (min.), Flange
Gain
4500 W
4250 W
65 dB min. at rated power (with no RF options);
67 dB min. at small signal (with no RF options);
deduct one dB of gain from the above minimums for each RF option
Gain Adjustment Range
20 dB min.
Gain Stability
±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.)
Input VSWR
2.5:1 typ;
1.5:1 typ. with optional input isolator
Output VSWR
2.5:1 typ.
Load VSWR
1.5:1 max. for full spec. compliance;
Peak output pulse power foldback protection at peak reflected power.
Will operate without damage or oscillation with any magnitude and phase of source and load impedance.
May oscillate with unshielded open due to coupling to input. Should not be tested with connector off.
Phase Noise
0.5°rms asynchronous ripple
Pulse Width
PRF
0.07 to 50 µs
50 kHz max, 100 kHz max. available as option
Duty Cycle
6% max.
Delay
300 ns typ; 400 ns max.
Droop
0.5 dB over 50 µs
-10 dBm/MHz Beam On;
110 dBm/MHz Beam Off
NPO
Primary Power
220 - 240 VAC ±10%, single phase 47- 63 Hz
2.2 kVA typ.
2.5 kVA max.
Power Consumption
Filament Voltage
Reduction of 10% in standby for extended TWT life
Inrush Current
200% max.
-10° to +40°C operating
-40° to +70°C non-operating
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
Cooling
95% non-condensing
10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating;
40,000 ft., non-operating
As normally encountered in a protected laboratory environment
Forced air with integral blower
Rear air intake & exhaust;
0.10” water max. external pressure oss allowable
RF Input Connection
Type N female
RF Output Connection
WRD-350 waveguide flange
RF Output Monitor
Dimensions (W x H x D)
Type N female, -46 dB nominal
19 x 14 x 26 in. (483 x 356 x 661 mm)
excluding connectors, fans, handles and exhaust duct
Weight
150 lbs (68 kg) max.
Heat Dissipation
2200 watts max.
Safety
EN61010
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 254, ISSUE 8 dated AUG 2015