VZL-6943J2 - Communications & Power Industries

s
L-Band
250 W Rack-Mount TWTA
Compact
Five rack units tall (8.75 in/222mm).
Versatile
Ultra wide-band, automatic fault recycle, user friendly
microprocessor-controlled logic with integrated computer
interface, digital metering, electronic variable attenuation,
soft fail when subjected to extreme load SWR conditions,
quite operation for a laboratory environment
Global Applications
230 VAC operation. Meets International Safety Standard
EN-60215 and Electromagnetic Compatibility 2004/108/EC
standards to satisfy world requirements.
Easy to Maintain
Modular design and built-in fault diagnostic capability
backed by CPI’s worldwide 24-hour customer
support network that includes more than 20 regional
factory service centers.
Model VZL-6943J2
1.0 to 2.5 GHz, 250 watt L-band
rack-mount TWTA for test and
measurement applications
OPTIONS
•Input isolator
•Remote control panel
•115 VAC external step-up transformer
Communications & Power Industries Canada Inc.
45 River Drive
Georgetown, Ontario, Canada L7G 2J4
tel:
+1 (905) 702-2228
fax:
+1 (905) 877-5327
e-mail:[email protected]
website:www.cpii.com/emc
L-Band
1.0 - 2.5 GHz
250 W Rack Mount TWTA
Specification
Model VZL-6943J2
Output Frequency
1.0 to 2.5 GHz
Output Power (min.)
TWT
Flange
250 W min. (300 W typ)
225 W min. (275 W typ), see graph on page 1
Gain
54 dB at rated power output, 56 dB min. at small signal
RF Level Adjust Range
0 to 20 dB
Gain Stability
±0.25 dB/24 hour max, at constant drive and temperature, after 30 minute warmup
Gain Variation
18 dB pk-pk typical
Input VSWR
2.5:1 max (2.0:1 max. with optional input isolator)
Output VSWR
2.5:1 typ.
Load VSWR
2.0:1 continuous operation; 1.5:1 for full spec. compliance; any value operation without damage
Residual AM
-50 dBc below 10 kHz; -20 [1.3 + logF (kHz)] dBc, 10 kHz to 500 kHz; -85 dBc above 500 kHz
Phase Noise
Meets IESS 308/309 with 3 dB margin
Noise and Spurious
-60 dBW/4 kHz
Noise Figure
15 dB max.
Harmonic Content
-3 dBc typical at lower band edge, decreasing to -15 dBc typical at upper band edge
Primary Power
Voltage: Single phase, 220-240 VAC ±10%; Frequency: 47-63 Hz, 15 A max.
Power Consumption
2.6 kVA typical, 3.0 kVA max.
Inrush Current
200% max.
Ambient Temperature
-10˚C to +40˚C operating
Relative Humidity
Altitude
95% non-condensing
10,000 ft. with standard adiabatic derating of 2˚C/1000 ft. operating; 50,000 ft. non-operating
Shock and Vibration
Cooling
Connections
As normall encountered in a protected engineering laboratory environment
Forced Air with integral blower. Rear air intake and exhaust. Maximum external pressure loss allowable: 0.5” water column
RF Input: Type N Female; RF output: Type N Female; RF output monitor: Type N Female, -50 dB nom.
M&C Interface
Serial RS232 or RS422/485
Dimensions, W x H x D
19 x 8.75 x 26 inches (483 x 222 x 661 mm)
Weight
110 lbs (50 kg) nom.
Safety
EN61010
Acoustic noise
65 dBA @ 3 feet from amplifier
VZL-6943J2 typical Psat and P1dB output power, dBm
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 397, ISSUE 1 dated JAN 2015