X-Band 5.0 kW Compact Pulse Amplifier Compact Eight rack-units tall (14 in/356 mm). Versatile Wide band, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, digital metering, and quiet operation suitable for laboratory environments. An integral solid state preamplifier and IEEE interface are included as standard features. Global Applications 230 VAC operation. Designed to meet International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Model VZX-3530J1 5000 Watt TWT Compact Pulsed Amplifier for Test and Measurement Applications OPTIONS •Remote Control Panel •Input Isolator (-1 dB Gain) Easy to Maintain Modular design and built-in fault diagnostic capability backed by CPI’s worldwide 24-hour customer support network that includes more than twenty regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc X-Band Specification Specifications 5.0 kW X-Band Compact Pulse Amplifier Model VZX-3530J1 Frequency 8.0 to 12.0 GHz Output Power (min.), TWT Output Power (min.), Flange Gain 5000 W 4800 W 65 dB min. at rated power (with no RF options); 67 dB min. at small signal (with no RF options); deduct one dB of gain from the above minimums for each RF option Gain Adjustment Range 20 dB min. Gain Stability ±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.) Input VSWR 2.5:1 typ; 1.5:1 typ. with optional input isolator Output VSWR 2.5:1 typ. Load VSWR 1.5:1 max. for full spec. compliance; Peak output pulse power foldback protection at peak reflected power. Will operate without damage or oscillation with any magnitude and phase of source and load impedance. May oscillate with unshielded open due to coupling to input. Should not be tested with connector off. Phase Noise 0.5°rms asynchronous ripple Pulse Width PRF 0.07 to 50 µs 50 kHz max, 100 kHz max. available as option Duty Cycle 6% max. Delay 400 ns typ. Droop 0.5 dB over 50 µs -10 dBm/MHz Beam On; -110 dBm/MHz Beam Off NPO Primary Power 220 - 240 VAC ±10%, single phase 47- 63 Hz 2.2 kVA typ. 2.5 kVA max. Power Consumption Filament Voltage Reduction of 10% in standby for extended TWT life Inrush Current Ambient Temperature 200% max. -10° to +40°C operating -40° to +70°C non-operating Relative Humidity Altitude Shock and Vibration Cooling (TWT) 95% non-condensing 10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 40,000 ft., non-operating As normally encountered in a protected laboratory environment Forced air with integral blower Rear air intake & exhaust; 0.10” water max. external pressure loss allowable RF Input Connection Type N female RF Output Connection WR-90 waveguide flange Dimensions (W x H x D) 19 x 14 x 26 in. (483 x 356 x 661 mm) excluding connectors, fans, handles and exhaust duct Weight 150 lbs (68 kg) max Heat Dissipation 2200 watts max. Safety EN61010 Acoustic Noise 65 dBA @ 3 ft. from amplifier Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 228, ISSUE 9 dated OCT 2015