C-Band 8000 Watt TWT Compact Pulse Amplifier Versatile Modular assembly allows for either lower powered multiple test applications or a single amplifier phase combined system of two VZC-3530J1 amplifiers achieving 8000 watts peak-pulsed output power. Wide band, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, digital metering, and quiet operation suitable for laboratory environments. An integral solid state preamplifier and IEEE interface are included as standard features. Global Applications 230 VAC operation. Designed to meet International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Easy to Maintain Modular design and built-in fault diagnostic capability. Global Applications Meets International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. NOT subject to ITAR export controls. Model VZC-3530P2 8.0 kW Combined Pulse Amplifier for Test and Measurement Applications OPTIONS •Remote Control Panel •Inpust Isolator (-1 dB Gain) Worldwide Support Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc C-Band Specifications 8000 Watt TWT Compact Pulse Amplifier Specification Model VZC-3530P2 Frequency 4.0 to 8.0 GHz Output Power (min.), TWT Output Power (min.), Flange 9000 W combined 8000 W typ, 7500 W min. Gain 65 dB min. at rated power; 70 dB typical Gain Adjustment Range 20 dB min. Gain Stability ±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.) Input VSWR 2.5:1 typ; 1.5:1 typ. with optional input isolator Output VSWR 2.5:1 typ. Load VSWR 1.5:1 max. for full spec. compliance; Any value for continuous operation (soft fail VSWR protection limits at 500 W peak) Phase Noise 0.5°rms asynchronous ripple Pulse Width 0.07 to 50 µs PRF 50 kHz max, 100 kHz max. available as option Duty Cycle 6% max. Delay 400 ns typ. Droop 0.5 dB over 50 µs -10 dBm/MHz Beam On; -110 dBm/MHz Beam Off NPO 220 - 240 VAC ±10%, single phase 47- 63 Hz Primary Power 2.2 kVA typ. 2.5 kVA max. Power Consumption Filament Voltage Reduction of 10% in standby for extended TWT life Inrush Current 200% max -10° to +40°C operating -40° to +70°C non-operating Ambient Temperature Relative Humidity Altitude Shock and Vibration Cooling (TWT) 95% non-condensing 10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 40,000 ft., non-operating As normally encountered in a protected laboratory environment Forced air with integral blower Rear air intake & exhaust; 0.10” water max. external pressure loss allowable RF Input Connection Type N female RF Output Connection WRD-350 waveguide Dimensions (W x H x D)* 19 x 37 x 27.5 in. (483 x 940 x 699 mm) System Weight 300 lbs (136 kg) Heat Dissipation 2200 watts max Safety EN61010 Acoustic Noise 65 dBA @ 3 ft. from amplifier Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 346, ISSUE 7 dated OCT 2015