VZC-3530P2

C-Band
8000 Watt TWT Compact Pulse Amplifier
Versatile
Modular assembly allows for either lower powered
multiple test applications or a single amplifier phase
combined system of two VZC-3530J1 amplifiers achieving
8000 watts peak-pulsed output power.
Wide band, automatic fault recycle, user-friendly
microprocessor-controlled logic with integrated computer
interface, digital metering, and quiet operation suitable for
laboratory environments.
An integral solid state preamplifier and IEEE interface are
included as standard features.
Global Applications
230 VAC operation. Designed to meet International
Safety Standard EN61010 and Electromagnetic
Compatibility 2004/108/EC.
Easy to Maintain
Modular design and built-in fault diagnostic capability.
Global Applications
Meets International Safety Standard EN61010 and
Electromagnetic Compatibility 2004/108/EC. NOT subject
to ITAR export controls.
Model VZC-3530P2
8.0 kW Combined Pulse Amplifier
for Test and Measurement
Applications
OPTIONS
•Remote Control Panel
•Inpust Isolator (-1 dB Gain)
Worldwide Support
Backed by over 35 years of satellite communications
experience, and CPI’s worldwide 24-hour customer support
network that includes more than 20 regional factory
service centers.
45 River Drive
Georgetown, Ontario, Canada L7G 2J4
tel:
+1 (905) 702-2228
fax:
+1 (905) 877-5327
e-mail:[email protected]
website:www.cpii.com/emc
C-Band
Specifications 8000 Watt TWT Compact Pulse Amplifier
Specification
Model VZC-3530P2
Frequency
4.0 to 8.0 GHz
Output Power (min.), TWT
Output Power (min.), Flange
9000 W combined
8000 W typ, 7500 W min.
Gain
65 dB min. at rated power;
70 dB typical
Gain Adjustment Range
20 dB min.
Gain Stability
±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.)
Input VSWR
2.5:1 typ;
1.5:1 typ. with optional input isolator
Output VSWR
2.5:1 typ.
Load VSWR
1.5:1 max. for full spec. compliance;
Any value for continuous operation (soft fail VSWR protection limits at 500 W peak)
Phase Noise
0.5°rms asynchronous ripple
Pulse Width
0.07 to 50 µs
PRF
50 kHz max, 100 kHz max. available as option
Duty Cycle
6% max.
Delay
400 ns typ.
Droop
0.5 dB over 50 µs
-10 dBm/MHz Beam On;
-110 dBm/MHz Beam Off
NPO
220 - 240 VAC ±10%,
single phase 47- 63 Hz
Primary Power
2.2 kVA typ.
2.5 kVA max.
Power Consumption
Filament Voltage
Reduction of 10% in standby for extended TWT life
Inrush Current
200% max
-10° to +40°C operating
-40° to +70°C non-operating
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
Cooling (TWT)
95% non-condensing
10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating;
40,000 ft., non-operating
As normally encountered in a protected laboratory environment
Forced air with integral blower
Rear air intake & exhaust;
0.10” water max. external pressure loss allowable
RF Input Connection
Type N female
RF Output Connection
WRD-350 waveguide
Dimensions (W x H x D)*
19 x 37 x 27.5 in. (483 x 940 x 699 mm)
System Weight
300 lbs (136 kg)
Heat Dissipation
2200 watts max
Safety
EN61010
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 346, ISSUE 7 dated OCT 2015