VZS/C-6963J2

S/C-Band
250 W and 320 W TWT Amplifiers
RF Output Power From 2.0 to 8.0 GHz
5RU TWTA provides minimum of 225 W at the flange.
Versatile
Ultra-wideband, automatic fault recycle, user friendly
microprocessor-controlled logic with integrated computer
interface, digital metering, electronic variable attenuation,
soft-fail when subjected to extreme load SWR conditions,
quiet operation for laboratory environment. An integral
solid state pre-amplifier and IEEE interface are included as
standard features.
Global Applications
230 VAC operation. Meets International Safety Standard
EN61010 and Electromagnetic Compatibility 2004/108/EC.
Model VZS/C-6963J2
250 watt and 320 W S/C-band TWTA
for EMC/EMI Test Applications
OPTIONS
•Input isolator (-1 dB gain)
•Remote control panel
•115 VAC external step-up transformer
Worldwide Support
Modular design and built-in fault diagnostic capability,
backed by CPI’s worldwide 24-hour customer support
network that includes more than twenty regional factory
service centers.
45 River Drive
Georgetown, Ontario, Canada L7G 2J4
tel:
+1 (905) 702-2228
fax:
+1 (905) 877-5327
e-mail:[email protected]
website:www.cpii.com/emc
S/C-Band
Specifications 250 W and 320 W S/C-Band TWTAs
Specification
Model VZS/C-6963J2
Frequency
2.0 to 8.0 GHz
320 W CW
250 W CW
224 W from 2.0 to 2.5 GHz, 290 W from 2.5 to 7.5 GHz,
275 W from 7.5 to 8.0 GHz
225 W CW
Output Power (min.), TWT
Output Power (min.), Flange
Bandwidth
6.0 GHz
Gain
54 dB min. at rated power output; 56 dB typ. at small signal
RF Level Adjust Range
0 to 20 dB continuous
Gain Stability
±0.25 dB/24 hr max. (after 30 minute warmup and at constant drive and temperature)
Gain Variation
12 dB pk-pk over 6.0 GHz bandwidth, typ.
VSWR
Input
Output
Load
2.5:1 typ, 1.7:1 max. (with optional input isolator)
2.5:1 typ.
1.5:1 max. full spec compliance; 2.0:1 max. continuous operation; any value without damage
Residual AM
-50 dBc below 10 kHz; -20[1.3 + log F (kHz)] dBc, 10 kHz to 500 kHz; -85 dBc above 500 kHz
Phase Noise
Meets IESS 308/309 with 3 dB margin
Noise and Spurious
-50 dBc typ. excluding harmonics
Harmonic Content
-3 dBc typ. at lower band edge
Prime Power
220 to 240 VAC single phase ±10%, 2 wire, 47 to 63 Hz
Power Consumption
2.6 kVA typ, 3.0 kVA max.
Inrush Current
200%
Ambient Temperature
-10°C to +40°C (derate by 1.9°C per 1,000 ft. above sea level); -40°C to +70°C non-operating
Relative Humidity
95% non-condensing
Operating Altitude
10,000 ft above sea level (3,048 m), with standard adiabatic de-rating of 2° per 1,000 feet; 40,000 ft non-operating
Shock and Vibration
Designed to meet conditions normally encountered in the laboratory
Acoustic Noise
65 dBA max. at three feet from amplifier
Cooling
Forced air with integral blower. Rear air intake and exhaust
Input RF Connector
Type N Female
Output RF Connector
Type N Female
RF Power Monitors
Type N Female, -50 dB nominal
Dimensions
19” H x 8.75” W x 26.0” L (483 x 222 x 661 mm)
Weight
110 lbs (50 kg) nom.
Safety
EN61010
tTyp
VZS/C6963J2 (2.0 - 8.0 GHz) 250 W Version
VZS/C6963J2 (2.0 - 8.0 GHz) 300 W version
450
450
400
400
350
350
300
300
250
250
200
200
150
150
100
100
50
50
0
2
2.5
3
3.5
4
4.5
5
O/P Power (Watts)
5.5
6
6.5
7
7.5
8
0
2
2.5
3
3.5
P1 dB
4
4.5
5
O/P Power (Watts)
5.5
6
6.5
7
7.5
8
P1 dB
Typical output power by frequency
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 224, ISSUE 5 dated JAN 2015