MKT-312B B4XO

100W GaN SSPA
With L-Band Block Upconverter
X- Band
Model B4XO-N
Global Applications
With CPI-built RF brick inside and plenty of
thermal margin, this SSPA is rock-solid and
highly efficient, utilizing state-of-the-art
GaN technology.
Perfect for Satcom on the Move, Micro
Flyaway Systems, VSATs, and antennamount applications. Meets Electromagnetic
Compatibility Directive 2004/108/EC to
satisfy worldwide requirements.
High LInearity
Excellent AM/PM, phase noise and spectral
regrowth performance.
Simple to Operate
User-friendly microprocessor-controlled
logic with Ethernet computer interface (serial
interface optional). Also contains digitally
controlled attenuator. Redundant systems
available.
Worldwide Support
Backed by over three decades of satellite
communications experience, and CPI’s
worldwide 24-hour customer support network
that includes sixteen regional factory
service centers.
The Basics
Provides 100 watts of output power over the
7.9 to 8.4 GHz frequency band.
811 Hansen Way
P.O. Box 51625, Palo Alto, CA 94303
tel: +1 (650) 846-3803
fax: +1 (650) 424-1744
e-mail: [email protected]
www.cpii.com/satcom
1 0 0 W G a N P o w e r S S PA w i t h B U C
CPI-Built RF Brick Inside
X-Band
100 W GaN power
X-band SSPA with
Block Upconverter environmentally sealed in
a compact package for
outdoor operation
X-B a n d
SPECIFICATIONS, 100 W GaN X-Band
Outdoor Solid State SSPA with BUC
(Model B4XO-N)
Monitor and Control
Electrical
OPTIONS:
• 1 RU Remote
Control Panel
• 1:1 Redundant
Switching
• Ethernet Interface
• AC Option
(requires external
converter module
- contact CPI for
details)
Frequency
7.9 to 8.4 GHz
L-Band Input
950 to 1450 MHz
Output Power
Saturated (Psat)
Linear (Plin)
100 W (50 dBm)
50 W (47 dBm)
Small Signal Gain
70 dB min.
External Reference
Frequency
Level
10 MHz
0 dBm ±5 dB
Internal Reference
Gain Stability
Over temp., constant drive
Over 24 hours, fixed temp.
±1.5 dB over oper. temp. range
±0.25 dB
±0.04 dB/MHz max.
Small Signal Gain Variation
Across any 40 MHz band
Across the full band
±0.3 dB pk-pk max.
±1.25 dB
Gain Adjustment Range
20 dB, 0.1 dB steps
Input VSWR
1.5:1 max. (50 ohms)
Output VSWR
1.3:1 max.
2.0:1
1.5:1
Residual AM, max.
-80 dBc > 100 kHz from carrier
Phase Noise, max.
10 Hz
100 Hz
1 kHz
10 kHz
100 KHz
1 MHz
-33 dBc/Hz
-63 dBc/Hz
-73 dBc/Hz
-83 dBc/Hz
-93 dBc/Hz
-93 dBc/Hz
AM/PM Conversion
2.0°/dB max. at Plin
Harmonic Output
-60 dBc max. at rated linear power
Spurious Response at Plin
-60 dBc max. in band
Noise Density
<-90 dBW/4 kHz, receive band
<-70 dBW/4 kHz, passband
Intermodulation Distortion
-25 dBc with two equal carriers at total
output power of 50 W
Spectral Regrowth
-30 dBc at 1 SR, OQPSK
Group Delay
(in any 80 MHz band)
0.03 ns/MHz linear max.
0.003 ns/MHz2 parabolic max.
1.0 ns pk-pk ripple max.
Primary Power
28 VDC ±20% (48 VDC ±20% optional)
Power Consumption
370 W typical
AC Option
100 - 240 VAC ±10%, 47-63 Hz
Power Factor Correction
.99 (when operating with AC option)
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
MKT 312B, ISSUE 10
12/11
PDF
Remote Status
Transmit/Standby/Inhibit Status
Control Point (local/CIF/Internet)
Environmental
Ambient Temperature
-40°C to +55°C operating
in direct sunlight;
-40°C to +60°C operating
out of direct sunlight;
-50°C to +85°C non-operating
Relative Humidity
100% condensing
Altitude
12,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
Cooling
Integral forced air
Shock and Vibration
20 g peak, 11 msec, 1/2 sine;
2.1 grms, 5 to 500 Hz.
Mechanical
RF Output Connection
Load VSWR
Continuous operation
Full spec compliance
Transmit ON/OFF
Fault Reset
Attenuator Setting
Computer/Network Interface RS-232C and 422/485
(Ethernet optional)
Standby option
±1 ppm stability
Gain Slope
Please contact CPI before using this information for system design.
Remote Control
CPR-112G waveguide flange
grooved with UNC-2B 10-32
threaded holes
L-Band Input Connection
Type N female
M&C Connection
Serial and basic Ethernet interface
Dimensions
width
height
length
Weight
5.2" (133 mm)
4.9" (125 mm)
11.5" (293 mm)
(optional AC input requires additional
external converter module - contact
CPI for details)