TRANSFORMERS AND INDUCTORS FOR LED LIGHTING APPLICATIONS o Designed for use with Power Intergrations Inc. LED Driver LNKSwitch-PH and LYTSwitch Controller Families. o Designed to meet UL/IEC 60950 Safety Standards. o Designed to meet Class B insulation. o Multiple configurations. o Design Engineering Support Available. GENERAL APPLICATION INFORMATION The Premier Magnetics, Inc's line of Transformers and Inductors listed in this brochure are designed specifically for use with Power Integrations, Inc. LNK series and LYT series lineup of LED Driver controllers. The PNK series of Transformers and Inductors are designed for use with the Power Integrations' LNK series of LED Driver controllers which combined offers very high power factor (> 90%), high efficiency (> 90% achievable) and an accurate constant current output for LED. The PNK series transformers provide a bias winding that allows the output voltage to be monitored from the primary side without the need of secondary side feedback components. The Premier Magnetic PNK-xxxxx line of LED Driver transformers and inductors have been optimized to provide the best possible constant current output to drive LED lighting. The POL-LYTxxx series of Transfomers and Inductors are designed for use with the Power Integrations' LYT series of LED driver controllers. This combination of LYT controllers and Premier Magnetics POL-LYT series Transformers and Inductors offers high efficiency (typically > 90%) and a tight constant current output that results in a stable LED drive performance. Premier Magnetics' POL-LYT series of Transformers and Inductors have been optimized to provide solid LED drive performance using a cost effective design. APPLICATION CIRCUIT LINE 90-265Vac 50/60Hz BR1 2KBPO 6M 600 V R12 10K F1 3.15A + L1 PM -PC1 19 RV1 275Vac C1 47 nF 275 V L2 PM -PC1 19 28 V 500 m A FL1 L3 PM -PC1 19 D7 EF3D -13-F T1 PNK-100 12 - R13 10K NEUT PREMIER M AG N ETIC S PART NU M BERS: (REQ U EST D ATA SHEETS BY PART NU M BER) T1 = PNK-10012 MA IN SW ITC HING TRAN SFOR MER L1, L2 & L3 = PM -PC 119 10000U h, 0.3A PO W ER C HO KE C9 330uF 50V C1 0 330uF 50V R11 20K 1% FL2 R1 510 1/2 W R17 510 2W R14 374K 1% 11 VR1 P6K E200A D1 DL4007 3 RTN R8 150 D6 DL4936 D2 UF4 007 R7 10K 1 C1 2 220 nF 630 V R15 374K 1% C2 100 nF 620V C3 1 uF 400V 2 R2 2M 1% D3 UF4 004 R3 2M 1% Q1 X0202M BL2 C1 1 470 nF 50 V D4 RS1B D6 BA V21W S -7-F R6 150K 1% R5 3K D V LinkSwitch-PH LNK4 06EG S R16 130 2W C5 22uF 50V R Q2 FM M 8T39 04 BP FB R4 49.9K 1% C4 10uF 16V R9 1K VR2 ZM M 525 9B-7 39V C6 100nF 50V R10 C 7 10K 1 uF 50V C8 2.2nF 250VAC Note: Schematic illustration above is of a universal input, 14 Watt LED Driver using the Power Integrations, Inc.'s LNK/406EG Per PI-RDR-195, with Premier Magnetics, Inc.'s Transformer PNK-10012 Inductor PM-PC119. Specifications subject to change without notice. pol 03/04 20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com 1 TRANSFORMERS AND INDUCTORS FOR LED LIGHTING APPLICATIONS o Designed for Use with Power Intergration LED Driver LNKSwitch-PH and LYTSwitch Controller Families. o Design complies with the requirements of UL/CSA/IEC 60950. o Design complies with the requirements of UL/CSA/IEC Class B insulation. CLICK ON THE RESPECTIVE PART NUMBER TO DISPLAY A DETAIL DATA SHEET PART NUMBER Power Integrations APPLICATION DATA Doc# Device POL-LYT020 POL-LYT021 TSD-3200 POL-LYT022 POL-LYT023 TSD-3192 POL-LYT024 POL-LYT025 POL-LYT026 POL-LYT027 POL-LYT028 POL-LYT029 DER-350 DER-364 DER-364 DER-347 DER-365 DER-365 DER-366 DER-357 DER-353 DER-359 DER-360 DER-355 LYT4317E LYT4313E LYT4313E LYT4313E LYT4311E LYT4311E LYT4314E LYT4313E LYT4314E LYT4312E LYT4311E LYT4312E 90-132 90-132 90-132 90-132 190-265 190-265 190-265 90-132 90-132 90-132 90-132 90-265 PNK-10010 PNK-10011 PNK-10012 PNK-10013 PNK-10014 PNK-10015 PNK-10016 PNK-10017 PNK-10018 PNK-10019 PNK-10020 PNK-10021 PNK-10022 PNK-10023 PNK-10024 PNK-10025 PNK-10026 PNK-10027 PNK-10029 PNK-10030 PNK-10031 PNK-10032 PNK-10033 PNK-10034 PNK-10035 DER-277 DER-281 DER-263 DER-286 RDR-290 DER-291 DER-296 DER-298 DER-302 DER-303 DER-304 DER-305 DER-306 DER-314 DER-315 DER-322 DER-323 DER-324 DER-328 DER-335 DER-336 DER-340 DER-341 DER-344 DER-351 LNK403EG LNK405EG LNK406EG LNK419EG LNK420EG LNK420EG LNK403EG LNK419EG LNK406VG LNK406VG LNK458KG LNK460VG LNK460VG LNK406VG LNK458VG LNK460VG LNK406VG LNK458DG LNK460KG LNK456DG LNK460KG LNK419EG LNK407EG LNK414EG LNK604DG 90-265 180-265 90-265 90-308 190-300 180-277 176-265 90-265 185-265 185-265 190-265 185-265 90-135 185-265 90-132 195-265 90-135 90-132 90-132 190-265 195-265 90-300 90-132 140-280 90-265 Input Volts Output Volts @ Currents (A) 36V 41V 41V 34V 41V 41V 36V 72V 18V 36V 15V 54V @ @ @ @ @ @ @ @ @ @ @ @ 0.550 0.350 0.350 0.370 0.350 0.350 0.550 0.170 0.530 0.230 0.500 0.110 18V @ 0.380 30V @ 0.50 28V @ 0.50 30V @ 1.0 29V-36V @ 2.1 30V-36V @ 4.2 66V @ 0.112 200V @ 0.09 36V @ 0.200 36V @ 0.200 48V @ 0.093 50V @ 0.200 36V @ 0.278 36V @ 0.425 48V @ 0.093 78V @ 0.230 85V @ 0.200 230V @ 0.030 30V-36V @ 0.280 100V @ 0.040 145V @ 0.040 54V @ 0.750 40V @ 0.350or 30V @ 0.480 16V @ 0.800 9V @ 0.330 Output Power (W) 20 14 14 12.6 14.35 14.35 20 12 9.5 8.5 7.5 6 7 15 14 30 75 150 7.4 18 7.2 7.2 4.5 10 10 15.3 4.5 18 18 7 10 4 5.8 40.5 14.5 12.8 3 Specifications subject to change without notice. 20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com 2