GAS SYSTEM SERIES 400 NATURAL GAS

GAS SYSTEM
SERIES 400 NATURAL GAS
480V / 60 Hz*
SYSTEM RATINGS
Natural gas genset without heat extraction
MTU Onsite
Energy Type
Former
Genset Type
GB 358 N6
AoE 3042 Z6
Output
Elec.1) Therm.2) Low Temp.4)
kWel. kBTU/hr kBTU/hr (°F)
358 (877)
---
Energy
input5)
kBTU/hr
3347
Efficiency
Electr. Total
nel. (%) ntot (%)
36.5
(62.7)
Methane
number6)
Energy
input5)
kBTU/hr
3347
Efficiency
Electr. Total
nel. (%) ntot (%)
36.5
62.7
Methane
number6)
≥ 70
Dimensions
(L x W x H)
in
155.1 x 66.5 x 83.9
Natural gas genset with heat extraction from jacket water
MTU Onsite
Energy Type
Former
Genset Type
GR 358 N6
AE 3042 Z6
Output
Elec.1) Therm.2) Low Temp.4)
kWel. kBTU/hr kBTU/hr (°F)
358 877
---
≥ 70
Dimensions
(L x W x H)
in
155.1 x 66.5 x 83.9
Natural gas genset with heat extraction from jacket water and exhaust gas (Cogeneration Module 194°/158°F)
MTU Onsite
Energy Type
Former
CHP Type
GC 128 N6**
GC 248 N6**
GC 358 N6
ME3066D3**
ME3042D3**
ME3042Z6
Output
Elec.1) Therm.3) Low Temp.4)
kWel. kBTU/hr kBTU/hr (°F)
128
730
--248 1445
--358 1791
---
Energy
input5)
kBTU/hr
1283
2495
3347
Efficiency
Electr. Total
nel. (%) ntot (%)
34.0
91.0
33.9
91.8
36.5
90.0
Methane
number6)
≥ 70
≥ 70
≥ 70
* NOx < 1 g/bhp-hr
** =1 with 3-Way-Catalyst, NOx < 0.5 g/bhp-hr
1) Rated power at nominal voltage, power factor = 1 and nominal frequency
2) from jacket water, tolerance 8%
3) from jacket water and exhaust gas, tolerance 8%
4) data only provided for external gas mixture cooler
5) performance data in accordance with ISO 3046/I-1991, tolerance 5%
6) referenced methane number
All data according to full load, indicated gas mixture cooler water inlet temperature and are subject to technical development.
Project specific data on request:
- Other gas types
- Container
- Individual data (e.g. flow-/return-temperatures, hot cooling, methane number, assembly space, etc.)
- Gas Processing
Dimensions
(L x W x H)
in
143.7 x 37.8 x 73.8
144.9 x 72.0 x 87.4
150.4 x 72.4 x 89.0
DS
EMA 1
M12*1.5
H
DRAWINGS AND DIMENSIONS
SS
93.25114-0067
93.25114-0067
TP65-230/2/50Hz
L
B
Note: This drawing is provided for reference only and should not be used for planning installation.
ENGINE DATA
in-line
6
130/155 mm (5.12/6.10 in)
2.06 lit. (126 cu in)
1800 rpm
DESIGN AND EQUIPMENT (EXTRACT)
// Sliding gear starter 24V
// Flexible coupling, interconnecting bell housing, service opening so
//
//
//
//
//
that replacement of the rubber element can be achieved without
displacing engine o generator
Gas supply through venturi air-gas mixer with electronically controlled
gas metering valve
Components of the gas regulation line approved per Directive for Gas
Components 90/356/EWG
Electronic high-voltage capacitor ignition system with one ignition coil
per cylinder
Electronic speed governor for speed and power output control with
automatic knocking control
Oil sump, removable without lifting the engine
Version: 28.09.2012, materials and specifications are subject to change without notice due to
technical advances.
MTU Onsite Energy
A Rolls-Royce Power Systems Brand
www.mtuonsiteenergy.com
3042
Configuration
No. of cylinders
Bore/Stroke
Cyl. displacement
Rated speed
90°V
12
130/142 mm (5.12/5.59 in)
1.88 lit. (115 cu in)
1800 rpm
Subject to change. | 3236741 | Edition 01/14 | ENC 2014-01 | Printed in Germany on chlorine-free bleached papaer.
3066
Configuration
No. of cylinders
Bore/Stroke
Cyl. displacement
Rated speed