LEB100F

Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LEB100F
LEB 100
1
2
F
3
-05
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
LEB
MODEL
V1
V2
DC OUTPUT
LEB100F-0512
+5V 5A
+12V 5(Peak 10)A
LEB100F-0324
+3.3V 5A
+24V 4(Peak 7)A
LEB100F-0524
+5V 5A
+24V 4(Peak 7)A
24
5
-O
6
1Series name
2Output wattage
3Universal input
4V1 Output voltage
5V2 Output voltage
6Optional *1 *8
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
T :Vertical terminal block
Y :with Potentiometer
Z :with ZT
LEB100F-0530
+5V 5A
+30V 3.2(Peak 5.6)A
LEB100F-0536
+5V 5A
+36V 2.7(Peak 4.7)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
TOTAL OUTPUT WATTAGE[W] *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *4
RIPPLE[mVp-p]
-10 - 0C *4
0 to +50C *4
RIPPLE NOISE[mVp-p]
-10 - 0C *4
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
DRIFT[mV]
*5
START-UP TIME[ms]
*6
HOLD-UP TIME[ms]
*6
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
V1
OVERCURRENT PROTECTION
V2
V1
OVERVOLTAGE PROTECTION
V2
REMOTE ON/OFF
INPUT-OUTPUT -RC
*7
INPUT-FG
OUTPUT-RC-FG
*7
OUTPUT-OUTPUT(V1 -RC-V2) *7
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEB100F-0512
LEB100F-0324
LEB100F-0524
LEB100F-0530
AC85 - 264 1f or DC 120 - 370
1.2typ (Io=100%)
1.4typ (Io=100%)
0.6typ (Io=100%)
0.7typ (Io=100%)
50/60 (47 - 63) or DC
74typ (Io=100%)
78typ (Io=100%)
78typ (Io=100%)
78typ (Io=100%)
76typ (Io=100%)
80typ (Io=100%)
80typ (Io=100%)
80typ (Io=100%)
0.98typ
0.99typ
0.93typ
15typ (Io=100%) (At cold start) (Ta=25 C)
30typ (Io=100%) (At cold start) (Ta=25 C)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+5
+12
+3.3
+24
+5
+24
+5
+30
0-5
0 - 5 (Peak 10) 0 - 5
0 - 4 (Peak 7) 0 - 5
0 - 4 (Peak 7) 0 - 5
0 - 3.2 (Peak 5.6)
85 (Peak 145)
100 (Peak 172)
100 (Peak 172)
100 (Peak 172)
20max
48max
20max
96max
20max
96max
20max
120max
40max
100max
40max
150max
40max
150max
40max
180max
80max
120max
80max
120max
80max
120max
80max
200max
140max
160max
140max
160max
140max
160max
140max
240max
120max
150max
120max
150max
120max
150max
120max
300max
160max
180max
160max
180max
160max
180max
160max
360max
50max
120max
50max
240max
50max
240max
50max
300max
60max
150max
60max
290max
60max
290max
60max
350max
20max
48max
20max
96max
20max
96max
20max
120max
250max
500max
250max
500max
250max
500max
250max
500max
40typ
20typ
40typ
20typ
40typ
20typ
40typ
20typ
4.5 - 5.5
Fixed
2.85 - 3.60 Fixed
4.5 - 5.5
Fixed
4.5 - 5.5
Fixed
11.5 - 12.5 xx
23.0 - 25.0 xx
23.0 - 25.0 xx
28.7 - 31.5
xx
Works over 105% of rating current and recovers automatically
Works over 101% of peak current and recovers automatically
Works over 115% of rating, by zener diode clamping
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *9
75X35X222mm [2.95X1.38X8.74 inches] (WXHXD) /420g max (without chassis and cover)
Convection
Specification is changed at option, refer to Instruction Manual 5.
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 4. In detail.
Refer to Instruction Manual 2.2 in detail.
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEB-2
*6
*7
*8
*9
*
*
*
LEB100F-0536
78typ (Io=100%)
80typ (Io=100%)
+5
+36
0-5
0 - 2.7 (Peak 4.7)
100 (Peak 172)
20max
144max
40max
180max
80max
200max
140max
240max
120max
300max
160max
360max
50max
300max
60max
350max
20max
144max
250max
500max
40typ
20typ
4.5 - 5.5
Fixed
34.5 - 37.5
xx
ACIN 100V,lo=100%
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Series/Parallel operation is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEB100F
External view
2-º4.5
[0.18]
CN1
CN2
4.5
[0.18]
4
5
8
(17)
Connector for Remote
ON/OFF (option)
(197)
[7.76] 212 + 0.5
[8.35]
5
[0.2]
º3.5-4.0 [0.14-0.16]
Mounting Hole
222
Connector for
-Z (option)
32
[0.12]
3max
(Lead)
CN4
º4.5
252
[0.18]
[9.92]
235-+0.5
8
[0.31]
CN3
RC(-)
PCB t=1.6
RC(+)
+ COM -
[0.06]
LEB
CN3
[9.25]
2-M4
Mounting
Hole
[1.26]
[8.74]
CN4
4.5
20 [0.18]
[0.79] 15
[0.59]
46
[1.81]
5
[0.2]
Voltage adjust(V1)
[0.67]
CN3
CN4
4-M4
Mounting
Hole
42
[1.65]
1
G2
+V2
G1
+V1
C119
FG
AC(N)
AC(L)
45-+0.5
[1.77]
25-+0.5
[0.98]
65-+0.5
[2.56]
5
3
1
PIN CONNECTION
I / O Connector Mating Connector
Terminal
Chain : SVH-21T-P1.1
CN1
B3P5-VH
VHR-5N
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
CN2
B8P-VH
VHR-8N
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
CN3
B2B-XH-A
XHP-2
(Option)
Loose: BXH-001T-P0.6
Chain : SXH-001T-P0.6
CN4
B3B-XH-A
XHP-3
(Option)
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
CN1
Pin No. Input
1
AC(L)
2
3
AC(N)
4
5
FG
CN2
Pin No. Output
G2
1, 2
V2
3, 4
G1
5, 6
V1
7, 8
CN3 (Option)
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
¶Weight: 420g max
(Without chassis and cover)
¶Tolerance: t1 [t0.04]
¶Dimensions in mm, [ ]= inches
¶PCB Material : CEM3
¶Chassis and cover is optional.
¶Mounting torque: 1.5N · m(16kgf · cm)max
CN4 (Option)
Pin No.
-Z
1
+
COM
2
3
¶Keep drawing current per pin below 5A for CN2
Performance data
¡RISE TIME & FALL TIME (LEB100F-0524)
¡EFFICIENCY (LEB100F-0524)
82
+24V
80
ACIN 100V Io=100%
DC Output
EFFICIENCY
78
+5V
76
74
AC Input
72
100ms/DIV
70
60
20ms/DIV
¡INPUT HARMONIC CURRENT (LEB100F-0524)
100
140
180
220
260
300
V
¡INPUT HARMONIC CURRENT (LEB100F-0524)
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
0.1
0.01
10
20
HARMONIC ORDER
30
Harmonic current standard class A
(at odd number)
A
A
Harmonic current standard class A
(at odd number)
0.001
0
Load factor100%
Load factor 50%
INPUT VOLTAGE
10
HARMONIC CURRENT
75
[2.95]
CN2
CN1
8
[0.31]
[9.25]
20
[0.79]
30
[1.18]
3-º3.5 [0.14]
Mounting
Hole
85
[3.35]
235-+0.5
Name plate
40
1
Load factor
100%
Input voltage AC 230V
0.1
0.01
0.001
0
10
20
30
40
HARMONIC ORDER
LEB-3
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LEB150F
LEB 150
1
2
F
3
-05
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
LEB
MODEL
V1
V2
DC OUTPUT
LEB150F-0512
+5V 5A
+12V 7.5(Peak 14)A
LEB150F-0324
+3.3V 5A
+24V 6(Peak 10)A
LEB150F-0524
+5V 5A
+24V 6(Peak 10)A
24
5
-O
6
1Series name
2Output wattage
3Universal input
4V1 Output voltage
5V2 Output voltage
6Optional *1 *8
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
T :Vertical terminal block
Y :with Potentiometer
Z :with ZT
LEB150F-0530
+5V 5A
+30V 4.8(Peak 8)A
LEB150F-0536
+5V 5A
+36V 4(Peak 6.7)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
TOTAL OUTPUT WATTAGE[W] *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +45C *4
RIPPLE[mVp-p]
-10 - 0C *4
0 to +45C *4
RIPPLE NOISE[mVp-p]
-10 - 0C *4
0 to +45C
TEMPERATURE REGULATION[mV]
-10 to +45C
DRIFT[mV]
*5
START-UP TIME[ms]
*6
HOLD-UP TIME[ms]
*6
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
V1
OVERCURRENT PROTECTION
V2
V1
OVERVOLTAGE PROTECTION
V2
REMOTE ON/OFF
INPUT-OUTPUT -RC
*7
INPUT-FG
OUTPUT-RC-FG
*7
OUTPUT-OUTPUT(V1 -RC-V2) *7
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEB150F-0512
LEB150F-0324
LEB150F-0524
LEB150F-0530
AC85 - 264 1f or DC 120 - 370
1.6typ (Io=100%)
2.0typ (Io=100%)
0.8typ (Io=100%)
1.0typ (Io=100%)
50/60 (47 - 63) or DC
76typ (Io=100%)
79typ (Io=100%)
79typ (Io=100%)
79typ (Io=100%)
79typ (Io=100%)
82typ (Io=100%)
82typ (Io=100%)
82typ (Io=100%)
0.98typ
0.99typ
0.93typ
15typ (Io=100%) (At cold start) (Ta=25 C)
30typ (Io=100%) (At cold start) (Ta=25 C)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+5
+12
+3.3
+24
+5
+24
+5
+30
0-5
0 - 7.5 (Peak 14) 0 - 5
0 - 6 (Peak 10) 0 - 5
0 - 6 (Peak 10) 0 - 5
0 - 4.8 (Peak 8)
115 (Peak 193)
150 (Peak 246)
150 (Peak 246)
150 (Peak 246)
20max
48max
20max
96max
20max
96max
20max
120max
40max
100max
40max
150max
40max
150max
40max
180max
80max
120max
80max
120max
80max
120max
80max
200max
140max
160max
140max
160max
140max
160max
140max
240max
120max
150max
120max
150max
120max
150max
120max
300max
160max
180max
160max
180max
160max
180max
160max
360max
50max
120max
50max
240max
50max
240max
50max
300max
60max
150max
60max
290max
60max
290max
60max
350max
20max
48max
20max
96max
20max
96max
20max
120max
250max
500max
250max
500max
250max
500max
250max
500max
40typ
20typ
40typ
20typ
40typ
20typ
40typ
20typ
4.5 - 5.5
Fixed
2.85 - 3.60 Fixed
4.5 - 5.5
Fixed
4.5 - 5.5
Fixed
11.5 - 12.5 xx
23.0 - 25.0 xx
23.0 - 25.0 xx
28.7 - 31.5
xx
Works over 105% of rating current and recovers automatically
Works over 101% of peak current and recovers automatically
Works over 115% of rating, by zener diode clamping
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *9
85X40X222mm [3.35X1.57X8.74 inches] (WXHXD) /530g max (without chassis and cover)
Convection
Specification is changed at option, refer to Instruction Manual 5.
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 4. In detail.
Refer to Instruction Manual 2.2 in detail.
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEB-4
*6
*7
*8
*9
*
*
*
LEB150F-0536
79typ (Io=100%)
82typ (Io=100%)
+5
+36
0-5
0 - 4 (Peak 6.7)
150 (Peak 246)
20max
144max
40max
180max
80max
200max
140max
240max
120max
300max
160max
360max
50max
300max
60max
350max
20max
144max
250max
500max
40typ
20typ
4.5 - 5.5
Fixed
34.5 - 37.5
xx
ACIN 100V,lo=100%
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Series/Parallel operation is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEB150F
External view
55-+0.5
[2.17]
35-+0.5
[1.38]
CN3
[0.2]
(24)
Voltage adjust(V1)
5
105 -+ 0.5
[0.2]
[4.13]
Connector for Remote
ON/OFF (option)
CN4
º3.5-4.0 [0.14-0.16]
Mounting Hole
Connector for
-Z (option)
(204)
[8.03]
CN1
4.5
4
5
8
CN4
5
47
CN2
1
212 -+ 0.5
[8.35]
222
[9.92]
235-+0.5
[9.25]
8
[0.31]
4.5
[0.18]
25 15
[0.98] [0.59]
51
[2.01]
[1.46]
37
Mounting
Hole
CN4
CN3
3max
[0.12]
(Lead)
RC(-)
I / O Connector Mating Connector
Terminal
Chain : SVH-21T-P1.1
CN1
B3P5-VH
VHR-5N
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
CN2
B8P-VH
VHR-8N
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
CN3
XHP-2
(Option) B2B-XH-A
Loose: BXH-001T-P0.6
Chain : SXH-001T-P0.6
CN4
B3B-XH-A
XHP-3
(Option)
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
LEB
CN3
252
º4.5
[0.18]
2-M4
[8.74]
RC(+)
+ COM -
PCB t=1.6
[0.06]
[1.85]
20
[0.79]
30
[1.18]
CN2
G2
+V2
G1
+V1
C119
4-M4
Mounting
Hole
[0.18]
FG
AC(N)
AC(L)
8
[0.31]
[0.94]
[2.95]
75-+0.5
[3.35]
85
CN1
5
3
1
235-+0.5
[9.25]
2-º4.5
[0.18]
95
[3.74]
4-º3.5 [0.14]
Mounting
Hole
Name plate
PIN CONNECTION
CN1
Pin No. Input
1
AC(L)
2
3
AC(N)
4
5
FG
CN2
Pin No. Output
G2
1, 2
V2
3, 4
G1
5, 6
V1
7, 8
CN3 (Option)
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
¶Weight: 530g max
(Without chassis and cover)
¶Tolerance: t1 [t0.04]
¶Dimensions in mm, [ ]= inches
¶PCB Material : CEM3
¶Chassis and cover is optional.
¶Mounting torque: 1.5N · m(16kgf · cm)max
CN4 (Option)
Pin No.
-Z
1
+
COM
2
3
¶Keep drawing current per pin below 5A(7A at peak load)for CN2
Performance data
¡RISE TIME & FALL TIME (LEB150F-0524)
¡EFFICIENCY (LEB150F-0524)
84
+24V
82
ACIN 100V Io=100%
DC Output
EFFICIENCY
80
+5V
78
76
AC Input
74
100ms/DIV
72
60
20ms/DIV
¡INPUT HARMONIC CURRENT (LEB150F-0524)
140
180
220
260
300
V
¡INPUT HARMONIC CURRENT (LEB150F-0524)
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
0.1
0.01
10
20
HARMONIC ORDER
30
Harmonic current standard class A
(at odd number)
A
Harmonic current standard class A
(at odd number)
A
HARMONIC CURRENT
100
INPUT VOLTAGE
10
0.001
0
Load factor100%
Load factor 50%
40
1
Load factor
100%
Input voltage AC 230V
0.1
0.01
0.001
0
10
20
30
40
HARMONIC ORDER
LEB-5
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LEB225F
LEB 225
1
2
F
3
-05
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
LEB
MODEL
V1
V2
DC OUTPUT
LEB225F-0512
+5V 5A
+12V 10(Peak 20)A
LEB225F-0324
+3.3V 5A
+24V 9(Peak 14)A
LEB225F-0524
+5V 5A
+24V 9(Peak 14)A
24
5
-O
6
1Series name
2Output wattage
3Universal input
4V1 Output voltage
5V2 Output voltage
6Optional *1 *8
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
T :Vertical terminal block
Y :with Potentiometer
Z :with ZT
LEB225F-0530
+5V 5A
+30V 7.2(Peak 11)A
LEB225F-0536
+5V 5A
+36V 6(Peak 9.3)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
TOTAL OUTPUT WATTAGE[W] *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +40C *4
RIPPLE[mVp-p]
-10 - 0C *4
0 to +40C *4
RIPPLE NOISE[mVp-p]
-10 - 0C *4
0 to +40C
TEMPERATURE REGULATION[mV]
-10 to +40C
DRIFT[mV]
*5
START-UP TIME[ms]
*6
HOLD-UP TIME[ms]
*6
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
V1
OVERCURRENT PROTECTION
V2
V1
OVERVOLTAGE PROTECTION
V2
REMOTE ON/OFF
INPUT-OUTPUT -RC
*7
INPUT-FG
OUTPUT-RC-FG
*7
OUTPUT-OUTPUT(V1 -RC-V2) *7
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEB225F-0512
LEB225F-0524
LEB225F-0530
=LEB225F-0324
AC85 - 264 1f or DC 120 - 370
1.9typ (Io=100%)
3.0typ (Io=100%)
1.0typ (Io=100%)
1.5typ (Io=100%)
50/60 (47 - 63) or DC
77typ (Io=100%)
81typ (Io=100%)
81typ (Io=100%)
81typ (Io=100%)
79typ (Io=100%)
83typ (Io=100%)
83typ (Io=100%)
83typ (Io=100%)
0.98typ
0.99typ
0.93typ
15typ (Io=100%) (More than 3sec.to re-start)
30typ (Io=100%) (More than 3sec.to re-start)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+5
+12
+3.3
+24
+5
+24
+5
+30
0-5
0 - 10 (Peak 20) 0 - 5
0 - 9 (Peak 14) 0 - 5
0 - 9 (Peak 14) 0 - 5
0 - 7.2 (Peak 11)
145 (Peak 265)
225 (Peak 345)
225 (Peak 345)
225 (Peak 345)
20max
48max
20max
96max
20max
96max
20max
120max
40max
100max
40max
150max
40max
150max
40max
180max
80max
120max
80max
120max
80max
120max
80max
200max
140max
160max
140max
160max
140max
160max
140max
240max
120max
150max
120max
150max
120max
150max
120max
300max
160max
180max
160max
180max
160max
180max
160max
360max
50max
120max
50max
240max
50max
240max
50max
300max
60max
150max
60max
290max
60max
290max
60max
350max
20max
48max
20max
96max
20max
96max
20max
120max
250max
500max
250max
500max
250max
500max
250max
500max
40typ
20typ
40typ
20typ
40typ
20typ
40typ
20typ
4.5 - 5.5
Fixed
2.85 - 3.60 Fixed
4.5 - 5.5
Fixed
4.5 - 5.5
Fixed
11.5 - 12.5 xx
23.0 - 25.0 xx
23.0 - 25.0 xx
28.7 - 31.5
xx
Works over 105% of rating current and recovers automatically
Works over 101% of peak current and recovers automatically
Works over 115% of rating, by zener diode clamping
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *9
95X45X222mm [3.74X1.77X8.74 inches] (WXHXD) /700g max (without chassis and cover)
Convection
Specification is changed at option, refer to Instruction Manual 5.
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 4. In detail.
Refer to Instruction Manual 2.2 in detail.
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEB-6
=LEB225F-0536
81typ (Io=100%)
83typ (Io=100%)
+5
+36
0-5
0 - 6 (Peak 9.3)
225 (Peak 345)
20max
144max
40max
180max
80max
200max
140max
240max
120max
300max
160max
360max
50max
300max
60max
350max
20max
144max
250max
500max
40typ
20typ
4.5 - 5.5
Fixed
34.5 - 37.5
xx
*6 ACIN 100V,lo=100%
*7 Applicable when remote control (optional) is added.
*8 Please contact us about safety approvals for the model with option.
*9 Please contact us about class C.
* Series/Parallel operation is not possible.
* Derating is required when operated with chassis and cover.
* A sound may occur from power supply at peak loading.
=marked models are pending for safety approvals. Consult with us for delivery.
LEB225F
External view
235-+0.5
[9.25]
[0.18]
10
º3.5-4.0 [0.14-0.16]
Mounting Hole
[7.87] 212 + 0.5
[8.35] 222
[8.74]
Connector for
-Z (option)
[9.92] 235+0.5
[9.25]
4.5
30
[1.18]
CN3
3max
(Lead)
RC(-)
[0.12]
108
[4.25]
8
[0.31]
Mounting
Hole
CN4
PCB t=1.6
RC(+)
+ COM -
LEB
CN3
252
º4.5
[0.18]
2-M4
[1.65]
42
CN4
15
[0.59]
58
[2.28]
5
[0.2]
Connector for Remote
ON/OFF (option)
Voltage
adjust(V1)
124 -+ 0.5
[4.88] (200)
4.5
CN3
CN4
5
[0.2]
CN1
[0.18]
6
7
[0.18]
G1
+V1
65-+0.5
[2.56]
45-+0.5
[1.77]
+V2
1
(15.5)
G2
52
CN2
CN2
C119
4-M4
Mounting
Hole
[0.61]
85-+0.5
[3.35]
95
[3.74]
5 FG
3 AC(N)
1 AC(L)
23
[0.91]
33
[1.3]
4-º3.5 [0.14]
Mounting
Hole
CN1
8
[0.31]
[2.05]
2-º4.5
Name plate
[0.06]
PIN CONNECTION
I / O Connector Mating Connector
Terminal
Chain : SVH-21T-P1.1
CN1
B3P5-VH
VHR-5N
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
CN2
B10P-VH VHR-10N
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
CN3
XHP-2
(Option) B2B-XH-A
Loose: BXH-001T-P0.6
Chain : SXH-001T-P0.6
CN4
XHP-3
(Option) B3B-XH-A
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
CN1
Pin No. Input
1
AC(L)
2
3
AC(N)
4
5
FG
CN2
Pin No. Output
1, 2, 3
G2
4, 5, 6
V2
7, 8
G1
9, 10
V1
CN3 (Option)
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
¶Weight: 700g max
(Without chassis and cover)
¶Tolerance:t1 [t0.04]
¶Dimensions in mm, [ ]= inches
¶PCB Material : CEM3
¶Chassis and cover is optional.
¶Mounting torque: 1.5N · m(16kgf · cm)max
CN4 (Option)
Pin No.
-Z
1
+
COM
2
3
¶Keep drawing current per pin below 5A (7A at peak load) for CN2
Performance data
¡RISE TIME & FALL TIME (LEB225F-0524)
¡EFFICIENCY (LEB225F-0524)
86
+24V
ACIN 100V Io=100%
EFFICIENCY
DC Output
84
+5V
AC Input
76
60
20ms/DIV
¡INPUT HARMONIC CURRENT (LEB225F-0524)
Load factor100%
Load factor 50%
100
140
180
220
INPUT VOLTAGE
260
300
V
¡INPUT HARMONIC CURRENT (LEB225F-0524)
10
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
0.1
0.01
10
20
HARMONIC ORDER
30
Harmonic current standard class A
(at odd number)
A
Harmonic current standard class A
(at odd number)
A
HARMONIC CURRENT
80
78
100ms/DIV
0.001
0
82
40
1
Load factor
100%
Input voltage AC 230V
0.1
0.01
0.001
0
10
20
30
40
HARMONIC ORDER
LEB-7