PBA1000F - Total Power International

Ordering information
Unit type
PBA1000F
PBA 1000
1
2
F
3
-5
4
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
R
PBA
Refer to instruction manual
7.1
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA1000F-3R3
660
ACIN 100V 3.3V 200A
ACIN 200V *3 3.3V 200A
PBA1000F-5
1000
5V 200A
5V 200A
PBA1000F-7R5
1005
7.5V 134A
7.5V 134A
PBA1000F-12
1056
12V 88A
12V 88A
PBA1000F-15
1050
15V 70A
15V 70A
PBA1000F-24
1056
24V 44A
24V 44(51)A
PBA1000F-36
1044
36V 29A
36V 29A
PBA1000F-48
1056
48V 22A
48V 22A
PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36
AC85 - 264 1f or DC120 - 350 (AC70 or DC100 optionally available *6)
9typ
13typ
5typ
7typ
50/60 (47 - 63)
74typ
79typ
80typ
82typ
82typ
84typ
84typ
76typ
81typ
83typ
84typ
84typ
86typ
86typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
3.3
5
7.5
12
15
24
36
200
200
134
88
70
44
29
200
200
134
88
70
44(51)
29
20max
20max
36max
48max
60max
96max
144max
40max
40max
60max
100max
120max
150max
150max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
200max
160max
160max
180max
180max
180max
180max
240max
40max
50max
75max
120max
150max
240max
360max
60max
75max
120max
180max
180max
290max
440max
12max
20max
30max
48max
60max
96max
144max
400typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off
20typ (ACIN 100/200V, Io=100%)
2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60
3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44
Works over 105% of rated current or 101% of peak current and recovers automatically
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4
LED (Green)
Provided
Provided
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature)
-20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
150X61X240mm (without terminal block and screw) (WXHXD) /2.2kg max
Forced cooling (internal fan)
PBA1000F-48
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
CURRENT[A]
ACIN 200V *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-20 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-20 - 0C *1
0 to +50C *1
TEMPERATURE REGULATION[mV]
-20 to +50C *1
DRIFT[mV]
*2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION *5
OVERVOLTAGE PROTECTION[V] *4
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :
RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
PBA-14
84typ
86typ
48
22
22
192max
300max
150max
400max
200max
500max
480max
600max
192max
the input voltage.
38.40 - 56.00
48.00 - 49.92
Vo+4.8 - 12.0
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting.
*5 The output voltage is shutted down the over current protection circuit operates continuosly for
about 5 sec.
* A sound may occur from power supply at pulse loading.
*6 Derating is required.Consult us for details.