PMP150 - PROTEK POWER

132-150 WATT MEDICAL & ITE POWER SUPPLIES
DESCRIPTION
PMP150 SERIES
(LVD)
The PMP150 series of AC/DC switching power supplies are
RoHS
for 132-150 watts of continuous output power. They are
enclosed in a 94 V-1 rated polyphenylene-oxide case with an
IEC320/C14 or IEC320/C18 inlet to mate with interchangeable
/
cord for world-wide use. All models meet EN55011, EN55022
and FCC class B emission limits, and are designed for
medical
and
ITE
applications,
not
for
life-supporting
equipment.
FEATURES
z
z
z
z
z
z
z
z
z
SAFETY STANDARD APPROVALS
Low safety ground leakage current
Both Class I and Class II models are certified
to medical and ITE safety standards.
W i d e i n p u t r a n g e 9 0 t o 2 6 4 VA C
Optional output connectors
100% burn-in
Overvoltage protection
Overcurrent protection
C o m p l i a n t w i t h C E C a n d E n e r g y St a r E f f i c i e n c y
level V requirements (except PMP150-12 and
PMP150-13 to level IV)
* No load power consumption less than 0.5 W
* Average active efficiency ≧ 87%
Compliant with RoHS requirements
UL 60601-1, CSA C22.2 No. 601.1
File No. E178020
TÜV EN 60601-1
UL 60950-1, CSA C22.2 No. 60950-1
File No. E137410
TÜV EN 60950-1
GENERAL SPECIFICATIONS
Switching frequency:
INPUT SPECIFICATIONS
Power factor:
Efficiency:
30-110 KHz
0.98 Typical at 115 VAC
Input voltage:
90-264 VAC
Input frequency:
47-63 Hz
Input current:
2.0 A (rms) for 115 VAC
Hold-up time:
15 ms minimum at 110 VAC
1.0 A (rms) for 230 VAC
Line regulation:
±0.5% maximum at full load
Inrush current:
60 A @ 115 VAC or 120 A @ 230 VAC, at
Withstand voltage:
4000 VAC from input to output,
Earth leakage current:
220 μA max. @ 264 VAC, 63 Hz
Touch current:
100 μA max. @ 264 VAC, 63 Hz
25℃ cold start
1500 VAC from input to ground,
OUTPUT SPECIFICATIONS
Output voltage /current:
See rating chart.
Maximum output power:
Ripple and noise:
Overvoltage protection:
See rating chart.
1% peak to peak maximum at full load
Provided and set at 112-140% of its
nominal output voltage
Protected to short circuit conditions
Overcurrent protection:
Temperature coefficient:
Transient response:
500 VAC from output to ground
MTBF:
150,000 hours at full load at 25℃ ambient ,
calculated per MIL-HDBK-217F
EMC Performance (IEC60601-1-2)
±0.04 /℃ maximum
Maximum excursion of 4% or better on
all models, recovering to 1% of final
value within 500 us after a 25% step
load change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Average active 87% min. (except 85% min.
for PMP150-12 and PMP150-13)
0℃ to +60℃
-40℃ to +85℃
5% to 95% non-condensing
Derate from 100% at +40℃
linearly to 50% at +60℃
EN55011 /EN55022:
Class B conducted, class B radiated
FCC:
Class B conducted, class B radiated
VCCI:
Class B conducted, class B radiated
EN61000-3-2:
Harmonic distortion, class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8 KV air and ±6 KV contact
EN61000-4-3:
Radiated immunity, 3 V/m
EN61000-4-4:
Fast transient/burst, ±2 KV
EN61000-4-5:
Surge, ±1 KV diff., ±2 KV com.
EN61000-4-6:
Conducted immunity, 3 Vrms
EN61000-4-8:
Magnetic field immunity, 3 A/m
EN61000-4-11:
Voltage dip immunity, 30% reduction for 500
ms, 60% reduction for 100 ms and >95%
reduction for 10 ms
55
UNIVERSAL INPUT
PMP150 MEDICAL & ITE SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Model
Class I
PMP150-12
PMP150-13
PMP150-13-2
PMP150-14
PMP150-15
PMP150-18
(1)
Output
Class II
PMP150F-12
PMP150F-13
PMP150F-13-2
PMP150F-14
PMP150F-15
PMP150F-18
V1
12.0 V
15.0 V
19.0 V
24.0 V
27.0 V
48.0 V
Min. Current Max. Current
11.00 A
0A
0A
9.00 A
0A
7.90 A
0A
6.25 A
0A
5.56 A
0A
3.13 A
Tol.
±5%
±5%
±5%
±5%
±5%
±5%
Ripple &
(2)
Noise
120 mV
150 mV
190 mV
240 mV
270 mV
480 mV
Max. Power
132 W
135 W
150 W
150 W
150 W
150 W
Average Active
Efficiency (typical)
@ 115 / 230 Vac
87 / 86 %
87 / 86 %
88 / 88 %
88 / 88 %
89 / 88 %
88 / 88 %
NOTES:
1.
Class I models are equipped with IEC320/C14 inlet, and class II models with IEC320/C18 inlet.
2.
Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load
ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output.
MECHANICAL SPECIFICATIONS
OUTPUT POWER DERATING CURVE
NOTES:
1.
Dimensions shown in inches [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Weight: 960 grams (2.1 lbs.) approx.
4.
Output connector is 4 pin plug without lock, mating with Kycon P/N KPJX-4S-S socket or equivalent.
5.
Refer to Section titled “OPTIONAL OUTPUT CONNECTORS”. Add the suffix assigned for a selected connector to a wanted model number,
e.g. PMP150-14-B1, for ordering.
PIN CHART
PIN
MODEL
PMP150-12
1
2
3
4
V1 Return
+V1
V1 Return
+V1
PMP150F-12
PMP150-13
PMP150F-13
PMP150-13-2
PMP150-14
PMP150-15
PMP150-18
PMP150F-13-2
PMP150F-14
PMP150F-15
PMP150F-18
56