132-150 WATT MEDICAL & ITE POWER SUPPLIES DESCRIPTION PMP150 SERIES (LVD) The PMP150 series of AC/DC switching power supplies are RoHS for 132-150 watts of continuous output power. They are enclosed in a 94 V-1 rated polyphenylene-oxide case with an IEC320/C14 or IEC320/C18 inlet to mate with interchangeable / cord for world-wide use. All models meet EN55011, EN55022 and FCC class B emission limits, and are designed for medical and ITE applications, not for life-supporting equipment. FEATURES z z z z z z z z z SAFETY STANDARD APPROVALS Low safety ground leakage current Both Class I and Class II models are certified to medical and ITE safety standards. W i d e i n p u t r a n g e 9 0 t o 2 6 4 VA C Optional output connectors 100% burn-in Overvoltage protection Overcurrent protection C o m p l i a n t w i t h C E C a n d E n e r g y St a r E f f i c i e n c y level V requirements (except PMP150-12 and PMP150-13 to level IV) * No load power consumption less than 0.5 W * Average active efficiency ≧ 87% Compliant with RoHS requirements UL 60601-1, CSA C22.2 No. 601.1 File No. E178020 TÜV EN 60601-1 UL 60950-1, CSA C22.2 No. 60950-1 File No. E137410 TÜV EN 60950-1 GENERAL SPECIFICATIONS Switching frequency: INPUT SPECIFICATIONS Power factor: Efficiency: 30-110 KHz 0.98 Typical at 115 VAC Input voltage: 90-264 VAC Input frequency: 47-63 Hz Input current: 2.0 A (rms) for 115 VAC Hold-up time: 15 ms minimum at 110 VAC 1.0 A (rms) for 230 VAC Line regulation: ±0.5% maximum at full load Inrush current: 60 A @ 115 VAC or 120 A @ 230 VAC, at Withstand voltage: 4000 VAC from input to output, Earth leakage current: 220 μA max. @ 264 VAC, 63 Hz Touch current: 100 μA max. @ 264 VAC, 63 Hz 25℃ cold start 1500 VAC from input to ground, OUTPUT SPECIFICATIONS Output voltage /current: See rating chart. Maximum output power: Ripple and noise: Overvoltage protection: See rating chart. 1% peak to peak maximum at full load Provided and set at 112-140% of its nominal output voltage Protected to short circuit conditions Overcurrent protection: Temperature coefficient: Transient response: 500 VAC from output to ground MTBF: 150,000 hours at full load at 25℃ ambient , calculated per MIL-HDBK-217F EMC Performance (IEC60601-1-2) ±0.04 /℃ maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: Average active 87% min. (except 85% min. for PMP150-12 and PMP150-13) 0℃ to +60℃ -40℃ to +85℃ 5% to 95% non-condensing Derate from 100% at +40℃ linearly to 50% at +60℃ EN55011 /EN55022: Class B conducted, class B radiated FCC: Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms, 60% reduction for 100 ms and >95% reduction for 10 ms 55 UNIVERSAL INPUT PMP150 MEDICAL & ITE SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Model Class I PMP150-12 PMP150-13 PMP150-13-2 PMP150-14 PMP150-15 PMP150-18 (1) Output Class II PMP150F-12 PMP150F-13 PMP150F-13-2 PMP150F-14 PMP150F-15 PMP150F-18 V1 12.0 V 15.0 V 19.0 V 24.0 V 27.0 V 48.0 V Min. Current Max. Current 11.00 A 0A 0A 9.00 A 0A 7.90 A 0A 6.25 A 0A 5.56 A 0A 3.13 A Tol. ±5% ±5% ±5% ±5% ±5% ±5% Ripple & (2) Noise 120 mV 150 mV 190 mV 240 mV 270 mV 480 mV Max. Power 132 W 135 W 150 W 150 W 150 W 150 W Average Active Efficiency (typical) @ 115 / 230 Vac 87 / 86 % 87 / 86 % 88 / 88 % 88 / 88 % 89 / 88 % 88 / 88 % NOTES: 1. Class I models are equipped with IEC320/C14 inlet, and class II models with IEC320/C18 inlet. 2. Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS OUTPUT POWER DERATING CURVE NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 960 grams (2.1 lbs.) approx. 4. Output connector is 4 pin plug without lock, mating with Kycon P/N KPJX-4S-S socket or equivalent. 5. Refer to Section titled “OPTIONAL OUTPUT CONNECTORS”. Add the suffix assigned for a selected connector to a wanted model number, e.g. PMP150-14-B1, for ordering. PIN CHART PIN MODEL PMP150-12 1 2 3 4 V1 Return +V1 V1 Return +V1 PMP150F-12 PMP150-13 PMP150F-13 PMP150-13-2 PMP150-14 PMP150-15 PMP150-18 PMP150F-13-2 PMP150F-14 PMP150F-15 PMP150F-18 56