www.emea.tdk-lambda.com/hws-me • Limited Lifetime Warranty • Medical Approvals • Universal Input (85 - 265VAC) • High Efficiency • Broad 30W to 1500W product range • RoHS Compliant Design Key Market Segments & Applications HWS-/ME Series Single Output Medical Power Supplies Medical Industrial Test Broadcast Comm Cots LED HWS-/ME Features and Benefits Features Benefits • Limited Lifetime Warranty • Medical Approvals • Wide Range AC Input • Lower Cost of Ownership • Reduces System Approval Times • Supports Global Use Specifications MODELS ITEM Input Voltage range Input Current (Typ) Inrush Current Power Factor / Flicker Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (60Hz) Remote Sense Indicator Remote On/Off Parallel operation DC Good Voltage Programming Operating Temperature and Derating Storage Temperature Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock (in packaging) Safety Agency Approvals Line Dip Conducted & Radiated EMI Immunity Weight (Typ) Size (WxHxD) (with cover except 30 & 50W) Warranty (1) (1) A A (2) V ms mA HWS30A HWS100A HWS50A HWS150A 85-265VAC (47-63Hz) 0.65 / 0.4 1.3 / 0.65 0.65 / 0.35 1.9 / 0.95 14 / 28 HWS300 HWS600 HWS1000 85-265VAC (47-63Hz) 4.1 / 2.1 HWS1500 85-265VAC (47-63Hz) 8.1 / 3.9 13.5/7.0 19/10 20 / 40 Meets EN61000-3-2, EN61000-3-3 <0.02%/°C >104% Yes (See table on page 2) 20 <0.5mA No Yes Green LED = ON No Yes (Isolated from output) No Single wire conn. (5 units max) No Yes No Yes - HWS30A-150A: -10°C to +70°C, (derating applies above 50°C please refer to individual model specification for derating graph) HWS300-1500: -10°C to +70°C, (-10 to +50°C: 100%, derate linearly to 50% load from +50°C to +70°C) °C -30°C to +85°C Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH Convection Internal fan Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100MΩ at 25°C & 70%RH, Output to Ground 500VDC, >10MΩ Output to remote on/off 100VDC 10 - 55Hz (1 min sweep), 19.6m/s2 constant, X, Y, Z axis, one hour each < 196.1m/s2 ES60601-1, EN60601-1, CSA-C22.2 No6011-M90 (C-UL) (basic insulation), CE Mark Complies with SEMI F47 (200VAC line only) EN55011 / EN55022-B, FCC-B, VCCI-B (HWS600 & 1500 Class A) IEC61000-4-2, -3, -4, -6, -8, -11, IEC61000-6-2 220 450 g 280 500 1000 1600 3200 3800 26 x 82 x 95 33 x 82 x 160 mm 26 x 82 x 120 42 x 82 x 160 61 x 82 x 165 100 x 82 x 165 126.5 x 82 x 240 280 x 82 x 126.5 Limited Lifetime Warranty (See TDK-Lambda terms & conditions) - (3) (2) Notes: (1) 100/200VAC input (2) See clause 19.5DV.2 of UL60601 for equipment in proximity of patient (3) HWS300-600 2.5kVAC Input to ground HWS-/ME Series 1 Model Selector Voltage Adjust Range Max Curr(A)4 HWS30A-5/ME HWS50A-5/ME HWS100A-5/ME HWS150A-5/ME HWS600-5/ME HWS30A-12/ME HWS50A-12/ME HWS100A-12/ME HWS150A-12/ME HWS300-12/ME HWS600-12/ME HWS30A-15/ME HWS50A-15/ME HWS100A-15/ME HWS150A-15/ME HWS300-15/ME HWS600-15/ME HWS30A-24/ME HWS50A-24/ME HWS100A-24/ME HWS150A-24/ME HWS300-24/ME HWS600-24/ME HWS1000-24/ME HWS1500-24/ME 5V 5V 5V 5V 5V 12V 12V 12V 12V 12V 12V 15V 15V 15V 15V 15V 15V 24V 24V 24V 24V 24V 24V 24V 24V 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 4.8 - 28.8(7) HWS1000-36/ME HWS1500-36/ME 36V 36V 28.8 - 43.2 7.2 - 43.2(6) HWS30A-48/ME HWS50A-48/ME HWS100A-48/ME HWS150A-48/ME HWS300-48/ME HWS600-48/ME HWS1000-48/ME HWS1500-48/ME 48V 48V 48V 48V 48V 48V 48V 48V 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38-4 - 52.8 9.6- 52.8(6) 6 10 20 30 120 2.5 4.3 8.5 13 27 53 2 3.5 7 10 22 43 1.3 2.2 4.5 6.5 14 (16.5 pk) 27 (31 pk) 46 (58.5 pk) 65/70(1) (105pk(5)) 30.7 (39 pk) 42/46.5(1) (70 pk)(5) 0.65 1.1 2.1 3.3 7 13 23 32 Model Max Load Line Ripple Power(W) Reg(mV) Reg(mV) Noise(mV) 30 50 100 150 600 30 51.6 102 156 324 636 30 52.5 105 150 330 645 31.2 52.8 108 156 336 648 1104 1560/1680(1) (2520 pk(5)) 1104 1512/1674(1) (2520 pk(5)) 31.2 52.8 100.8 158.4 336 624 1104 1536 40 40 40 40 30 96 96 96 96 72 72 120 120 120 120 90 90 192 192 192 192 144 144 150 144 20 20 20 20 20 48 48 48 48 48 48 60 60 60 60 60 60 96 96 96 96 96 96 96 96 120 120 120 120 120 150 150 150 150 150 150 150 150 150 150 150 150 200 150 150 150 150 150 150 200 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7.25 15-17.4 15-17.4 15-17.4 15-17.4 15-17.4 15-17.4 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 77/80 82/84 83/86 83/86 80/83 81/83 81/83 83/86 83/86 80/83 80/83 81/83 81/83 83/86 83/86 82/85 81/84 83/86 82/84 84/87 85/88 82/85 82/85 85/87 84/88 150 150 144 144 200 200 45-49.7 34-49.7 85/88 84/88 384 384 384 384 288 288 300 288 192 192 192 192 192 192 192 192 200 200 200 200 350 350 200 200 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-60 55.2-64.8 82/83 83/85 84/87 85/88 82/85 83/86 86/88 86/90 (4) Peak load for 10s maximum on time, 35% duty cycle (5) 200-265AC Input (6) Using voltage programming input - see installation manual for details Options 2 Suffix Description Blank /A No cover (except HWS300-1500 cover fitted) as standard Cover fitted (egHWSA100-24/MEA) option available for HWSA100 & HWSA150 only Overvoltage Efficiency (V) (typ)%1 HWS-/ME Series Outline Drawing HWS100A/MEA Series ,13879$&$ +] 2873879$ (+)3 5 ,13879$&$+] 2873879$ ,13879$&$+] 2873879$ Outline Drawing HWS300 Series OUTPUT : 24V 14A INPUT : 100-240VAC 4.7A MAX. 50/60Hz OUTPUT : 24V 14A CN1 CN2 2 1 +S +Vm -S -Vm COM PC EN60601-1 NC NC TOG CNT TOG PF 12 11 OUTPUT : 24V 14A Outline Drawing HWS1500 Series 12 2 11 1 (+) EN60601-1 INPUT : 100-240VAC 20 A MAX. 50 / 60Hz 2 1 12 11 (+) EN60601-1 INPUT : 100-240VAC 20 A MAX. 50 / 60Hz HWS-/ME Series 3 TDK-Lambda France SAS TDK-Lambda UK Ltd. ZAC des Delaches CS 41077 9 rue Thuillere 91978 Villebon Courtaboeuf France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 [email protected] www.fr.tdk-lambda.com Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 [email protected] www.uk.tdk-lambda.com Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 [email protected] www.it.tdk-lambda.com Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 [email protected] www.tdk-lambda.co.il [email protected] www.tdk-lambda.nl C.I.S. TDK-Lambda Ltd. Italy Sales Office Netherlands Commercial Support: Tel: +7 (495) 665 2627 Technical Support: Tel: +7 (812) 658 0463 [email protected] www.tdk-lambda.ru TDK-Lambda Germany GmbH Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 [email protected] www.de.tdk-lambda.com Local Distribution Austria Sales Office Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 [email protected] www.de.tdk-lambda.com Scandinavia Sales Office Valdemarsgade 7 4100 Ringsted Denmark Tel: +45 24 63 95 65 Fax: +45 69 80 44 99 [email protected] www.emea.tdk-lambda.com Switzerland Sales Office Bahnhofstrasse 50 8305 Dietlikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 [email protected] www.de.tdk-lambda.com www.emea.tdk-lambda.com HWS-/ME Sept14 v2 4 HWS-/ME Series