Project Number: ACX 10u” Gold ELP Report Requested by: James Borgelt Tracking Code: 207757_Test Report_Rev 1 Date: 11/29/2012 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly Test Start: 7/18/2012 Product Rev: D Lot #: N/A Tech: Aaron McKim Test Completed: 8/17/2012 ACX 10u” GOLD EXTENDED DURABILITY TEST REPORT ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Page 1 of 21 Eng: Eric Mings Qty to test: 20 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly REVISION HISTORY DATA REV.NUM. 11/28/2012 1 DESCRIPTION Initial Issue Page 2 of 21 ENG CE Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly CERTIFICATION All instruments and measuring equipment were calibrated to National Institute for Standards and Technology (NIST) traceable standards according to IS0 10012-l and ANSI/NCSL 2540-1, as applicable. All contents contained herein are the property of Samtec. No portion of this report, in part or in full shall be reproduced without prior written approval of Samtec. SCOPE To perform the following tests: Design Qualification test. Please see test plan. APPLICABLE DOCUMENTS Standards: EIA Publication 364 TEST SAMPLES AND PREPARATION 1) 2) 3) 4) 5) 6) 7) 8) 9) All materials were manufactured in accordance with the applicable product specification. All test samples were identified and encoded to maintain traceability throughout the test sequences. After soldering, the parts to be used for LLCR testing were cleaned according to TLWI-0001. Either an automated cleaning procedure or an ultrasonic cleaning procedure may be used. The automated procedure is used with aqueous compatible soldering materials. Parts not intended for testing LLCR are visually inspected and cleaned if necessary. Any additional preparation will be noted in the individual test sequences. Solder Information: Lead Free Samtec Test PCBs used: PCB-103219-TST-XX Page 3 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly FLOWCHARTS Extended Life TEST GROUP A1 GROUP B1 GROUP C1 STEP 4 Assemblies 4 Assemblies 4 Assemblies 01 02 100 Cycles * Plating Thickness Verification LLCR-1 250 Cycles * Plating Thickness Verification LLCR-1 500 Cycles * Plating Thickness Verification LLCR-1 03 100 Cycles 250 Cycles 500 Cycles 04 Clean Mating Interface Clean Mating Interface Clean Mating Interface 05 LLCR-2 Thermal Shock (Mated and undisturbed) LLCR-3 Cyclic Humidity (Mated and undisturbed) LLCR-4 LLCR-2 Thermal Shock (Mated and undisturbed) LLCR-3 Cyclic Humidity (Mated and undisturbed) LLCR-4 LLCR-2 Thermal Shock (Mated and undisturbed) LLCR-3 Cyclic Humidity (Mated and undisturbed) LLCR-4 06 07 08 09 10 *** Photos of Contact Area *** Photos of Contact Area *** Photos of Contact Area Therm al Shock = EIA-364-32, Table II, Test Condition I: -55oC to +85oC 1/2 hour dw ell, 100 cycles Hum idity =EIA-364-31, Test Condition 'B' (240 Hours) and Method III (+25°C to +65°C @ 90% RH to 98% RH) am bient pre-condition and delete steps 7a and 7b LLCR = EIA-364-23, LLCR 20 m V Max, 100 m A Max Use Keithley 580 or 3706 in 4 w ire dry circuit m ode * Measure, verify, and docum ent plating thickness on both m ale and fem ale (one group only) ** Plating thickness to be m easured on loose pins used during assem bly. Pins to be provided by requestor. *** Save 2-3 photos of contact area in project folder for each group Page 4 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly ATTRIBUTE DEFINITIONS The following is a brief, simplified description of attributes. THERMAL SHOCK: 1) 2) 3) 4) 5) 6) EIA-364-32, Thermal Shock (Temperature Cycling) Test Procedure for Electrical Connectors. Test Condition 1: -55°C to +85°C Test Time: ½ hour dwell at each temperature extreme Number of Cycles: 100 All test samples are pre-conditioned at ambient. All test samples are exposed to environmental stressing in the mated condition. HUMIDITY: 1) 2) 3) 4) 5) Reference document: EIA-364-31, Humidity Test Procedure for Electrical Connectors. Test Condition B, 240 Hours. Method III, +25° C to + 65° C, 90% to 98% Relative Humidity excluding sub-cycles 7a and 7b. All samples are pre-conditioned at ambient. All test samples are exposed to environmental stressing in the mated condition. MATING/UNMATING: 1) Reference document: EIA-364-13, Mating and Unmating Forces Test Procedure for Electrical Connectors. 2) The full insertion position was to within 0.003” to 0.004” of the plug bottoming out in the receptacle to prevent damage to the system under test. 3) One of the mating parts is secured to a floating X-Y table to prevent damage during cycling. LLCR: 1) EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. 2) A computer program, LLCR 221.exe, ensures repeatability for data acquisition. 3) The following guidelines are used to categorize the changes in LLCR as a result from stressing a. <= +5.0 mOhms:----------------------------- Stable b. +5.1 to +10.0 mOhms: ---------------------- Minor c. +10.1 to +15.0 mOhms: -------------------- Acceptable d. +15.1 to +50.0 mOhms: -------------------- Marginal e. +50.1 to +2000 mOhms: ------------------- Unstable f. >+2000 mOhms: ----------------------------- Open Failure Page 5 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly RESULTS ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 LLCR Extended Life 100 cycles: (4 Assemblies) ACP-16-01 Initial -------------------------------------------------------------- 140.75 mOhms Max Durability, 100 Cycles o <= +5.0 mOhms ------------------------------------ 54 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 2 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 50 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 5 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 1 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 48 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 6 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 2 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure LLCR Extended Life 250 cycles: (4 Assemblies) ACP-16-01 Initial -------------------------------------------------------------- 138.03mOhms Max Durability, 250 Cycles o <= +5.0 mOhms ------------------------------------ 56 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 52 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 4 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 56 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Page 6 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly RESULTS Continued LLCR Extended Life 500 cycles: (4 Assemblies) ACP-16-01 Initial -------------------------------------------------------------- 138.14mOhms Max Durability, 500 Cycles o <= +5.0 mOhms ------------------------------------ 56 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 53 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 3 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 50 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 6 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 LLCR Extended Life 100 cycles: (4 Assemblies) ACP-16-02 Initial --------------------------------------------------------------- 53.61 mOhms Max Durability, 100 Cycles o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Page 7 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly RESULTS Continued LLCR Extended Life 250 cycles: (4 Assemblies) ACP-16-02 Initial --------------------------------------------------------------- 54.09 mOhms Max Durability, 250 Cycles o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure LLCR Extended Life 500 cycles: (4 Assemblies) ACP-16-02 Initial --------------------------------------------------------------- 53.78 mOhms Max Durability, 500 Cycles o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Page 8 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly RESULTS Continued ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1 LLCR Extended Life 100 cycles: (4 Assemblies) ACP-16-03 Initial --------------------------------------------------------------- 10.15 mOhms Max Durability, 100 Cycles o <= +5.0 mOhms ------------------------------------16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure LLCR Extended Life 250 cycles: (4 Assemblies) ACP-16-03 Initial --------------------------------------------------------------- 10.33mOhms Max Durability, 250 Cycles o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Page 9 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly RESULTS Continued LLCR Extended Life 500 cycles: (4 Assemblies) ACP-16-03 Initial --------------------------------------------------------------- 10.10 mOhms Max Durability, 500 Cycles o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Thermal Shock o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Humidity o <= +5.0 mOhms ------------------------------------ 15 Points ------------------------- Stable o +5.1 to +10.0 mOhms ----------------------------------- 1 Points ------------------------- Minor o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure Page 10 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 LLCR Extended Life 100 cycles: 1) 2) 3) 4) A total of 56 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 100 Cycles Series: ACP-16-01-G-P/ACR-16-01-G-P Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count LLCR Measurement Summaries by Pin Type 7/18/2012 7/24/2012 7/30/2012 8/16/2012 22 22 22 22 45 49 43 40 Aaron McKim Aaron McKim Troy Cook Aaron McKim Actual Delta Delta Delta Initial 100 Cycles Therm Shck Humidity Pin Type 1: Signal 136.81 0.92 1.97 2.34 1.49 1.48 2.49 2.79 133.97 0.08 0.03 0.00 140.75 8.30 11.70 11.92 56 56 56 56 56 56 56 56 LLCR Delta Count by Category mOhms 100 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 54 2 0 0 0 50 5 1 0 0 48 6 2 0 0 Page 11 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 LLCR Extended Life 250 cycles: 1) 2) 3) 4) A total of 56 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 250 Cycles Series: ACP-16-01-G-P/ACR-16-01-G-P LLCR Measurement Summaries by Pin Type Date 7/18/2012 7/24/2012 7/30/2012 Room Temp (Deg C) 22 22 22 Rel Humidity (%) 44 49 43 Technician Aaron McKim Aaron McKim Troy Cook mOhm values Actual Delta Delta Initial 250 Cycles Therm Shck Pin Type 1: Signal Average 134.79 0.34 0.96 St. Dev. 1.19 0.75 1.73 Min 132.63 0.00 0.03 Max 138.03 4.80 8.02 Summary Count 56 56 56 Total Count 56 56 56 8/16/2012 22 42 Aaron McKim Delta Humidity 0.66 0.66 0.01 2.93 56 56 LLCR Delta Count by Category mOhms 250 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 56 0 0 0 0 52 4 0 0 0 56 0 0 0 0 Page 12 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 LLCR Extended Life 500 cycles: 1) 2) 3) 4) A total of 56 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 500 Cycles Series: ACP-16-01-G-P/ACR-16-01-G-P LLCR Measurement Summaries by Pin Type Date 7/18/2012 7/24/2012 7/30/2012 Room Temp (Deg C) 22 22 22 Rel Humidity (%) 44 49 43 Technician Aaron McKim Aaron McKim Troy Cook mOhm values Actual Delta Delta Initial 500 Cycles Therm Shck Pin Type 1: Signal Average 135.87 0.34 1.16 St. Dev. 1.13 0.32 1.59 Min 133.69 0.01 0.04 Max 138.14 1.85 8.57 Summary Count 56 56 56 Total Count 56 56 56 8/16/2012 22 41 Aaron McKim Delta Humidity 1.73 2.27 0.00 9.48 56 56 LLCR Delta Count by Category mOhms 500 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 56 0 0 0 0 53 3 0 0 0 50 6 0 0 0 Page 13 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 LLCR Extended Life 100 cycles: 1) 2) 3) 4) A total of 40 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 100 cycles Series: ACP/ACR-16-02 LLCR Measurement Summaries by Pin Type Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count 7/25/2012 22 51 Troy Cook Actual Initial 52.76 0.42 51.92 53.61 40 40 7/31/2012 8/8/2012 22 22 46 38 Troy Cook Troy Cook Delta Delta 100 Cycles Therm Shck Pin Type 1: Signal 0.06 0.20 0.06 0.14 0.00 0.00 0.25 0.64 40 40 40 40 8/21/2012 23 36 Troy Cook Delta Humidity 0.72 0.97 0.01 4.91 40 40 LLCR Delta Count by Category Stable Minor Acceptable Marginal Unstable mOhms <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 100 Cycles 40 0 0 0 0 Therm Shck 40 0 0 0 0 Humidity 40 0 0 0 0 Page 14 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 LLCR Extended Life 250 cycles: 1) 2) 3) 4) A total of 40 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 250 Cycles Series: ACP/ACR-16-02 LLCR Measurement Summaries by Pin Type Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count 7/25/2012 22 51 Troy Cook Actual Initial 8/8/2012 22 38 Troy Cook Delta 250 Cycles 52.83 0.47 51.92 54.09 40 40 0.12 0.07 0.01 0.31 40 40 8/14/2012 21 41 Troy Cook Delta Therm Shck Pin Type 1: Signal 0.20 0.11 0.01 0.41 40 40 8/27/2012 22 44 Troy Cook Delta Humidity 0.24 0.25 0.00 1.08 40 40 LLCR Delta Count by Category mOhms 250 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 40 0 0 0 0 40 0 0 0 0 40 0 0 0 0 Page 15 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 LLCR Extended Life 500 cycles: 1) 2) 3) 4) A total of 40 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 500 Cycles Series: ACP/ACR-16-02 LLCR Measurement Summaries by Pin Type Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count 7/25/2012 22 51 Troy Cook Actual Initial 52.73 0.47 51.83 53.78 40 40 8/9/2012 8/14/2012 22 21 42 41 Troy Cook Troy Cook Delta Delta 500 Cycles Therm Shck Pin Type 1: Signal 0.11 0.21 0.05 0.08 0.00 0.01 0.21 0.33 40 40 40 40 8/27/2012 22 44 Troy Cook Delta Humidity 0.27 0.31 0.00 2.11 40 40 LLCR Delta Count by Category mOhms 500 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 40 0 0 0 0 40 0 0 0 0 40 0 0 0 0 Page 16 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1 LLCR Extended Life 100 cycles: 1) 2) 3) 4) A total of 16 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 100 Cycles Series: ACP/ACR-16-03 LLCR Measurement Summaries by Pin Type Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count 8/1/2012 22 44 Troy Cook Actual Initial 9.57 0.27 9.30 10.15 16 16 8/2/2012 8/8/2012 22 22 40 38 Troy Cook Troy Cook Delta Delta 100 Cycles Therm Shck Pin Type 1: Signal 0.08 0.14 0.04 0.20 0.01 0.00 0.21 0.72 16 16 16 16 8/21/2012 23 36 Troy Cook Delta Humidity 0.30 0.42 0.01 1.38 16 16 LLCR Delta Count by Category mOhms 100 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 16 0 0 0 0 16 0 0 0 0 16 0 0 0 0 Page 17 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1 LLCR Extended Life 250 cycles: 1) 2) 3) 4) A total of 16 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 250 Cycles Series: ACP/ACR-16-03 LLCR Measurement Summaries by Pin Type Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count 8/1/2012 22 45 Troy Cook Actual Initial 9.58 0.29 9.27 10.33 16 16 8/2/2012 8/8/2012 22 23 42 38 Troy Cook Troy Cook Delta Delta 250 Cycles Therm Shck Pin Type 1: Signal 0.09 0.10 0.13 0.13 0.01 0.00 0.49 0.53 16 16 16 16 8/21/2012 23 36 Troy Cook Delta Humidity 0.32 0.51 0.00 2.22 16 16 LLCR Delta Count by Category mOhms 250 Cycles Therm Shck Humidity Stable Minor Acceptable Marginal Unstable <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 16 0 0 0 0 16 0 0 0 0 16 0 0 0 0 Page 18 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly DATA SUMMARIES CONTINUED ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1 LLCR Extended Life 500 cycles: 1) 2) 3) 4) A total of 16 points were measured. EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets. A computer program, LLCR 221.exe, ensures repeatability for data acquisition. The following guidelines are used to categorize the changes in LLCR as a result from stressing. a. <= +5.0 mOhms: ---------------------------- Stable b. +5.1 to +10.0 mOhms: --------------------- Minor c. +10.1 to +15.0 mOhms: ------------------- Acceptable d. +15.1 to +50.0 mOhms: ------------------- Marginal e. +50.1 to +2000 mOhms ------------------- Unstable f. >+2000 mOhms: ---------------------------- Open Failure LLCR Results for Test: Extended Life 500 Cycles Series: ACP/ACR-16-03 LLCR Measurement Summaries by Pin Type Date Room Temp (Deg C) Rel Humidity (%) Technician mOhm values Average St. Dev. Min Max Summary Count Total Count 8/1/2012 22 45 Troy Cook Actual Initial 9.54 0.25 9.31 10.10 16 16 8/3/2012 8/8/2012 22 23 47 37 Troy Cook Troy Cook Delta Delta 500 Cycles Therm Shck Pin Type 1: Signal 0.04 0.12 0.04 0.20 0.00 0.00 0.18 0.84 16 16 16 16 8/21/2012 23 36 Troy Cook Delta Humidity 0.61 1.20 0.01 5.09 16 16 LLCR Delta Count by Category Stable Minor Acceptable Marginal Unstable mOhms <=5 >5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000 500 Cycles 16 0 0 0 0 Therm Shck 16 0 0 0 0 Humidity 15 1 0 0 0 Page 19 of 21 Open >1000 0 0 0 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly EQUIPMENT AND CALIBRATION SCHEDULES Equipment #: MO-04 Description: Multimeter /Data Acquisition System Manufacturer: Keithley Model: 2700 Serial #: 0798688 Accuracy: See Manual … Last Cal: 03/27/2012, Next Cal: 03/27/2013 Equipment #: MO-11 Description: System Switch Multimeter /Data Acquisition System Manufacturer: Keithley Model: 3706 Serial #: Accuracy: See Manual … Last Cal: 09/24/2012, Next Cal: 09/30/2013 Equipment #: THC-01 Description: Temperature/Humidity Chamber Manufacturer: Thermotron Model: SE-1000-6-6 Serial #: 31808 Accuracy: See Manual … Last Cal: 09/18/2012, Next Cal: 09/18/2013 Equipment #: TSC-01 Description: Vertical Thermal Shock Chamber Manufacturer: Cincinnatti Sub Zero Model: VTS-3-6-6-SC/AC Serial #: 10-VT14993 Accuracy: See Manual … Last Cal: 05/13/2012, Next Cal: 05/13/2013 Equipment #: TCT-04 Description: Dillon Quantrol TC2 Test Stand Manufacturer: Dillon Quantrol Model: TC2 Serial #: 04-1041-04 Accuracy: Speed Accuracy: +/- 5% of indicated speed; Displacement: +/- 5 micrometers. … Last Cal: 05/03/2012, Next Cal: 05/03/2013 Page 20 of 21 Tracking Code: 207757_Test Report_Rev 1 Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1 ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1 Part description: Acclimate Circular Cable Assembly EQUIPMENT AND CALIBRATION SCHEDULES CONTINUED Equipment #: TCT-07 Description: Chatillon Manufacturer: Chatillon Model: LF Plus Serial #: LF1310 Accuracy: See Manual … Last Cal: 07/13/2012, Next Cal: 07/13/2013 Equipment #: TCT-05 Description: Chatillon TCD Series Manufacturer: Chatillon Model: TCD2255 Serial #: TCD0071 Accuracy: See Manual … Last Cal: 11/01/2012, Next Cal: 11/01/2013 Page 21 of 21