Project Number:

Project Number: ACX 10u” Gold ELP Report
Requested by: James Borgelt
Tracking Code: 207757_Test Report_Rev 1
Date: 11/29/2012
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
Test Start: 7/18/2012
Product Rev: D
Lot #: N/A
Tech: Aaron McKim
Test Completed: 8/17/2012
ACX 10u” GOLD EXTENDED DURABILITY TEST REPORT
ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Page 1 of 21
Eng: Eric Mings
Qty to test: 20
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
REVISION HISTORY
DATA
REV.NUM.
11/28/2012
1
DESCRIPTION
Initial Issue
Page 2 of 21
ENG
CE
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
CERTIFICATION
All instruments and measuring equipment were calibrated to National Institute for Standards and Technology (NIST)
traceable standards according to IS0 10012-l and ANSI/NCSL 2540-1, as applicable.
All contents contained herein are the property of Samtec. No portion of this report, in part or in full shall be
reproduced without prior written approval of Samtec.
SCOPE
To perform the following tests: Design Qualification test. Please see test plan.
APPLICABLE DOCUMENTS
Standards: EIA Publication 364
TEST SAMPLES AND PREPARATION
1)
2)
3)
4)
5)
6)
7)
8)
9)
All materials were manufactured in accordance with the applicable product specification.
All test samples were identified and encoded to maintain traceability throughout the test sequences.
After soldering, the parts to be used for LLCR testing were cleaned according to TLWI-0001.
Either an automated cleaning procedure or an ultrasonic cleaning procedure may be used.
The automated procedure is used with aqueous compatible soldering materials.
Parts not intended for testing LLCR are visually inspected and cleaned if necessary.
Any additional preparation will be noted in the individual test sequences.
Solder Information: Lead Free
Samtec Test PCBs used: PCB-103219-TST-XX
Page 3 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
FLOWCHARTS
Extended Life
TEST
GROUP A1
GROUP B1
GROUP C1
STEP
4 Assemblies
4 Assemblies
4 Assemblies
01
02
100 Cycles
* Plating Thickness
Verification
LLCR-1
250 Cycles
* Plating Thickness
Verification
LLCR-1
500 Cycles
* Plating Thickness
Verification
LLCR-1
03
100 Cycles
250 Cycles
500 Cycles
04
Clean Mating Interface
Clean Mating Interface
Clean Mating Interface
05
LLCR-2
Thermal Shock
(Mated and undisturbed)
LLCR-3
Cyclic Humidity
(Mated and undisturbed)
LLCR-4
LLCR-2
Thermal Shock
(Mated and undisturbed)
LLCR-3
Cyclic Humidity
(Mated and undisturbed)
LLCR-4
LLCR-2
Thermal Shock
(Mated and undisturbed)
LLCR-3
Cyclic Humidity
(Mated and undisturbed)
LLCR-4
06
07
08
09
10
*** Photos of Contact Area *** Photos of Contact Area
*** Photos of Contact Area
Therm al Shock = EIA-364-32, Table II, Test Condition I:
-55oC to +85oC 1/2 hour dw ell, 100 cycles
Hum idity =EIA-364-31, Test Condition 'B' (240 Hours)
and Method III (+25°C to +65°C @ 90% RH to 98% RH)
am bient pre-condition and delete steps 7a and 7b
LLCR = EIA-364-23, LLCR
20 m V Max, 100 m A Max
Use Keithley 580 or 3706 in 4 w ire dry circuit m ode
* Measure, verify, and docum ent plating thickness on both m ale and fem ale (one group only)
** Plating thickness to be m easured on loose pins used during assem bly. Pins to be provided by requestor.
*** Save 2-3 photos of contact area in project folder for each group
Page 4 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
ATTRIBUTE DEFINITIONS
The following is a brief, simplified description of attributes.
THERMAL SHOCK:
1)
2)
3)
4)
5)
6)
EIA-364-32, Thermal Shock (Temperature Cycling) Test Procedure for Electrical Connectors.
Test Condition 1: -55°C to +85°C
Test Time: ½ hour dwell at each temperature extreme
Number of Cycles: 100
All test samples are pre-conditioned at ambient.
All test samples are exposed to environmental stressing in the mated condition.
HUMIDITY:
1)
2)
3)
4)
5)
Reference document: EIA-364-31, Humidity Test Procedure for Electrical Connectors.
Test Condition B, 240 Hours.
Method III, +25° C to + 65° C, 90% to 98% Relative Humidity excluding sub-cycles 7a and 7b.
All samples are pre-conditioned at ambient.
All test samples are exposed to environmental stressing in the mated condition.
MATING/UNMATING:
1) Reference document: EIA-364-13, Mating and Unmating Forces Test Procedure for Electrical Connectors.
2) The full insertion position was to within 0.003” to 0.004” of the plug bottoming out in the receptacle to
prevent damage to the system under test.
3) One of the mating parts is secured to a floating X-Y table to prevent damage during cycling.
LLCR:
1) EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
2) A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
3) The following guidelines are used to categorize the changes in LLCR as a result from stressing
a. <= +5.0 mOhms:----------------------------- Stable
b. +5.1 to +10.0 mOhms: ---------------------- Minor
c. +10.1 to +15.0 mOhms: -------------------- Acceptable
d. +15.1 to +50.0 mOhms: -------------------- Marginal
e. +50.1 to +2000 mOhms: ------------------- Unstable
f. >+2000 mOhms: ----------------------------- Open Failure
Page 5 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
RESULTS
ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
LLCR Extended Life 100 cycles: (4 Assemblies)
ACP-16-01
Initial -------------------------------------------------------------- 140.75 mOhms Max
Durability, 100 Cycles
o <= +5.0 mOhms ------------------------------------ 54 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 2 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 50 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 5 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 1 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 48 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 6 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 2 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
LLCR Extended Life 250 cycles: (4 Assemblies)
ACP-16-01
Initial -------------------------------------------------------------- 138.03mOhms Max
Durability, 250 Cycles
o <= +5.0 mOhms ------------------------------------ 56 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 52 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 4 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 56 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Page 6 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
RESULTS Continued
LLCR Extended Life 500 cycles: (4 Assemblies)
ACP-16-01
Initial -------------------------------------------------------------- 138.14mOhms Max
Durability, 500 Cycles
o <= +5.0 mOhms ------------------------------------ 56 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 53 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 3 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 50 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 6 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
LLCR Extended Life 100 cycles: (4 Assemblies)
ACP-16-02
Initial --------------------------------------------------------------- 53.61 mOhms Max
Durability, 100 Cycles
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Page 7 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
RESULTS Continued
LLCR Extended Life 250 cycles: (4 Assemblies)
ACP-16-02
Initial --------------------------------------------------------------- 54.09 mOhms Max
Durability, 250 Cycles
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
LLCR Extended Life 500 cycles: (4 Assemblies)
ACP-16-02
Initial --------------------------------------------------------------- 53.78 mOhms Max
Durability, 500 Cycles
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 40 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Page 8 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
RESULTS Continued
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1
LLCR Extended Life 100 cycles: (4 Assemblies)
ACP-16-03
Initial --------------------------------------------------------------- 10.15 mOhms Max
Durability, 100 Cycles
o <= +5.0 mOhms ------------------------------------16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
LLCR Extended Life 250 cycles: (4 Assemblies)
ACP-16-03
Initial --------------------------------------------------------------- 10.33mOhms Max
Durability, 250 Cycles
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Page 9 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
RESULTS Continued
LLCR Extended Life 500 cycles: (4 Assemblies)
ACP-16-03
Initial --------------------------------------------------------------- 10.10 mOhms Max
Durability, 500 Cycles
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Thermal Shock
o <= +5.0 mOhms ------------------------------------ 16 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 0 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Humidity
o <= +5.0 mOhms ------------------------------------ 15 Points ------------------------- Stable
o +5.1 to +10.0 mOhms ----------------------------------- 1 Points ------------------------- Minor
o +10.1 to +15.0 mOhms --------------------------------- 0 Points ------------------------- Acceptable
o +15.1 to +50.0 mOhms --------------------------------- 0 Points ------------------------- Marginal
o +50.1 to +2000 mOhms --------------------------------- 0 Points ------------------------- Unstable
o >+2000 mOhms ------------------------------------------ 0 Points ------------------------- Open Failure
Page 10 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES
ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
LLCR Extended Life 100 cycles:
1)
2)
3)
4)
A total of 56 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 100 Cycles
Series:
ACP-16-01-G-P/ACR-16-01-G-P
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
LLCR Measurement Summaries by Pin Type
7/18/2012
7/24/2012
7/30/2012
8/16/2012
22
22
22
22
45
49
43
40
Aaron McKim Aaron McKim Troy Cook Aaron McKim
Actual
Delta
Delta
Delta
Initial
100 Cycles Therm Shck Humidity
Pin Type 1: Signal
136.81
0.92
1.97
2.34
1.49
1.48
2.49
2.79
133.97
0.08
0.03
0.00
140.75
8.30
11.70
11.92
56
56
56
56
56
56
56
56
LLCR Delta Count by Category
mOhms
100 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
54
2
0
0
0
50
5
1
0
0
48
6
2
0
0
Page 11 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
LLCR Extended Life 250 cycles:
1)
2)
3)
4)
A total of 56 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 250 Cycles
Series: ACP-16-01-G-P/ACR-16-01-G-P
LLCR Measurement Summaries by Pin Type
Date 7/18/2012
7/24/2012
7/30/2012
Room Temp (Deg C)
22
22
22
Rel Humidity (%)
44
49
43
Technician Aaron McKim Aaron McKim Troy Cook
mOhm values
Actual
Delta
Delta
Initial
250 Cycles Therm Shck
Pin Type 1: Signal
Average
134.79
0.34
0.96
St. Dev.
1.19
0.75
1.73
Min
132.63
0.00
0.03
Max
138.03
4.80
8.02
Summary Count
56
56
56
Total Count
56
56
56
8/16/2012
22
42
Aaron McKim
Delta
Humidity
0.66
0.66
0.01
2.93
56
56
LLCR Delta Count by Category
mOhms
250 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
56
0
0
0
0
52
4
0
0
0
56
0
0
0
0
Page 12 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
LLCR Extended Life 500 cycles:
1)
2)
3)
4)
A total of 56 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 500 Cycles
Series: ACP-16-01-G-P/ACR-16-01-G-P
LLCR Measurement Summaries by Pin Type
Date 7/18/2012
7/24/2012
7/30/2012
Room Temp (Deg C)
22
22
22
Rel Humidity (%)
44
49
43
Technician Aaron McKim Aaron McKim Troy Cook
mOhm values
Actual
Delta
Delta
Initial
500 Cycles Therm Shck
Pin Type 1: Signal
Average
135.87
0.34
1.16
St. Dev.
1.13
0.32
1.59
Min
133.69
0.01
0.04
Max
138.14
1.85
8.57
Summary Count
56
56
56
Total Count
56
56
56
8/16/2012
22
41
Aaron McKim
Delta
Humidity
1.73
2.27
0.00
9.48
56
56
LLCR Delta Count by Category
mOhms
500 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
56
0
0
0
0
53
3
0
0
0
50
6
0
0
0
Page 13 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
LLCR Extended Life 100 cycles:
1)
2)
3)
4)
A total of 40 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 100 cycles
Series:
ACP/ACR-16-02
LLCR Measurement Summaries by Pin Type
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
7/25/2012
22
51
Troy Cook
Actual
Initial
52.76
0.42
51.92
53.61
40
40
7/31/2012
8/8/2012
22
22
46
38
Troy Cook
Troy Cook
Delta
Delta
100 Cycles
Therm Shck
Pin Type 1: Signal
0.06
0.20
0.06
0.14
0.00
0.00
0.25
0.64
40
40
40
40
8/21/2012
23
36
Troy Cook
Delta
Humidity
0.72
0.97
0.01
4.91
40
40
LLCR Delta Count by Category
Stable
Minor
Acceptable Marginal
Unstable
mOhms
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
100 Cycles
40
0
0
0
0
Therm Shck
40
0
0
0
0
Humidity
40
0
0
0
0
Page 14 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
LLCR Extended Life 250 cycles:
1)
2)
3)
4)
A total of 40 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 250 Cycles
Series:
ACP/ACR-16-02
LLCR Measurement Summaries by Pin Type
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
7/25/2012
22
51
Troy Cook
Actual
Initial
8/8/2012
22
38
Troy Cook
Delta
250 Cycles
52.83
0.47
51.92
54.09
40
40
0.12
0.07
0.01
0.31
40
40
8/14/2012
21
41
Troy Cook
Delta
Therm Shck
Pin Type 1: Signal
0.20
0.11
0.01
0.41
40
40
8/27/2012
22
44
Troy Cook
Delta
Humidity
0.24
0.25
0.00
1.08
40
40
LLCR Delta Count by Category
mOhms
250 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
40
0
0
0
0
40
0
0
0
0
40
0
0
0
0
Page 15 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
LLCR Extended Life 500 cycles:
1)
2)
3)
4)
A total of 40 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 500 Cycles
Series:
ACP/ACR-16-02
LLCR Measurement Summaries by Pin Type
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
7/25/2012
22
51
Troy Cook
Actual
Initial
52.73
0.47
51.83
53.78
40
40
8/9/2012
8/14/2012
22
21
42
41
Troy Cook
Troy Cook
Delta
Delta
500 Cycles
Therm Shck
Pin Type 1: Signal
0.11
0.21
0.05
0.08
0.00
0.01
0.21
0.33
40
40
40
40
8/27/2012
22
44
Troy Cook
Delta
Humidity
0.27
0.31
0.00
2.11
40
40
LLCR Delta Count by Category
mOhms
500 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
40
0
0
0
0
40
0
0
0
0
40
0
0
0
0
Page 16 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1
LLCR Extended Life 100 cycles:
1)
2)
3)
4)
A total of 16 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 100 Cycles
Series:
ACP/ACR-16-03
LLCR Measurement Summaries by Pin Type
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
8/1/2012
22
44
Troy Cook
Actual
Initial
9.57
0.27
9.30
10.15
16
16
8/2/2012
8/8/2012
22
22
40
38
Troy Cook
Troy Cook
Delta
Delta
100 Cycles
Therm Shck
Pin Type 1: Signal
0.08
0.14
0.04
0.20
0.01
0.00
0.21
0.72
16
16
16
16
8/21/2012
23
36
Troy Cook
Delta
Humidity
0.30
0.42
0.01
1.38
16
16
LLCR Delta Count by Category
mOhms
100 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
16
0
0
0
0
16
0
0
0
0
16
0
0
0
0
Page 17 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1
LLCR Extended Life 250 cycles:
1)
2)
3)
4)
A total of 16 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 250 Cycles
Series: ACP/ACR-16-03
LLCR Measurement Summaries by Pin Type
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
8/1/2012
22
45
Troy Cook
Actual
Initial
9.58
0.29
9.27
10.33
16
16
8/2/2012
8/8/2012
22
23
42
38
Troy Cook
Troy Cook
Delta
Delta
250 Cycles
Therm Shck
Pin Type 1: Signal
0.09
0.10
0.13
0.13
0.01
0.00
0.49
0.53
16
16
16
16
8/21/2012
23
36
Troy Cook
Delta
Humidity
0.32
0.51
0.00
2.22
16
16
LLCR Delta Count by Category
mOhms
250 Cycles
Therm Shck
Humidity
Stable
Minor
Acceptable Marginal
Unstable
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
16
0
0
0
0
16
0
0
0
0
16
0
0
0
0
Page 18 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
DATA SUMMARIES CONTINUED
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-03-G-00.35-S-BC-P-1
LLCR Extended Life 500 cycles:
1)
2)
3)
4)
A total of 16 points were measured.
EIA-364-23, Low Level Contact Resistance Test Procedure for Electrical Connectors and Sockets.
A computer program, LLCR 221.exe, ensures repeatability for data acquisition.
The following guidelines are used to categorize the changes in LLCR as a result from stressing.
a. <= +5.0 mOhms: ---------------------------- Stable
b. +5.1 to +10.0 mOhms: --------------------- Minor
c. +10.1 to +15.0 mOhms: ------------------- Acceptable
d. +15.1 to +50.0 mOhms: ------------------- Marginal
e. +50.1 to +2000 mOhms ------------------- Unstable
f. >+2000 mOhms: ---------------------------- Open Failure
LLCR Results for Test: Extended Life 500 Cycles
Series:
ACP/ACR-16-03
LLCR Measurement Summaries by Pin Type
Date
Room Temp (Deg C)
Rel Humidity (%)
Technician
mOhm values
Average
St. Dev.
Min
Max
Summary Count
Total Count
8/1/2012
22
45
Troy Cook
Actual
Initial
9.54
0.25
9.31
10.10
16
16
8/3/2012
8/8/2012
22
23
47
37
Troy Cook
Troy Cook
Delta
Delta
500 Cycles
Therm Shck
Pin Type 1: Signal
0.04
0.12
0.04
0.20
0.00
0.00
0.18
0.84
16
16
16
16
8/21/2012
23
36
Troy Cook
Delta
Humidity
0.61
1.20
0.01
5.09
16
16
LLCR Delta Count by Category
Stable
Minor
Acceptable Marginal
Unstable
mOhms
<=5
>5 & <=10 >10 & <=15 >15 & <=50 >50 & <=1000
500 Cycles
16
0
0
0
0
Therm Shck
16
0
0
0
0
Humidity
15
1
0
0
0
Page 19 of 21
Open
>1000
0
0
0
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
EQUIPMENT AND CALIBRATION SCHEDULES
Equipment #: MO-04
Description: Multimeter /Data Acquisition System
Manufacturer: Keithley
Model: 2700
Serial #: 0798688
Accuracy: See Manual
… Last Cal: 03/27/2012, Next Cal: 03/27/2013
Equipment #: MO-11
Description: System Switch Multimeter /Data Acquisition System
Manufacturer: Keithley
Model: 3706
Serial #:
Accuracy: See Manual
… Last Cal: 09/24/2012, Next Cal: 09/30/2013
Equipment #: THC-01
Description: Temperature/Humidity Chamber
Manufacturer: Thermotron
Model: SE-1000-6-6
Serial #: 31808
Accuracy: See Manual
… Last Cal: 09/18/2012, Next Cal: 09/18/2013
Equipment #: TSC-01
Description: Vertical Thermal Shock Chamber
Manufacturer: Cincinnatti Sub Zero
Model: VTS-3-6-6-SC/AC
Serial #: 10-VT14993
Accuracy: See Manual
… Last Cal: 05/13/2012, Next Cal: 05/13/2013
Equipment #: TCT-04
Description: Dillon Quantrol TC2 Test Stand
Manufacturer: Dillon Quantrol
Model: TC2
Serial #: 04-1041-04
Accuracy: Speed Accuracy: +/- 5% of indicated speed; Displacement: +/- 5 micrometers.
… Last Cal: 05/03/2012, Next Cal: 05/03/2013
Page 20 of 21
Tracking Code: 207757_Test Report_Rev 1
Part #: ACP-16-01-G-00.35-T-BC-P-1/ACR-16-01-G-00.35-S-BC-P-1
ACP-16-02-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
ACP-16-03-G-00.35-T-BC-P-1/ACR-16-02-G-00.35-S-BC-P-1
Part description: Acclimate Circular Cable Assembly
EQUIPMENT AND CALIBRATION SCHEDULES CONTINUED
Equipment #: TCT-07
Description: Chatillon
Manufacturer: Chatillon
Model: LF Plus
Serial #: LF1310
Accuracy: See Manual
… Last Cal: 07/13/2012, Next Cal: 07/13/2013
Equipment #: TCT-05
Description: Chatillon TCD Series
Manufacturer: Chatillon
Model: TCD2255
Serial #: TCD0071
Accuracy: See Manual
… Last Cal: 11/01/2012, Next Cal: 11/01/2013
Page 21 of 21