TYPE EXAMINATION CERTIFICATE [1] Equipment or Protective System intended for use in Potentially Explosive Atmospheres Directive 94/9/EC [2] DEMKO 14 ATEX 1393U Rev. 0 [3] Type Examination Certificate Number: [4] Component: [5] Manufacturer: [6] Address: [7] This Component and any acceptable variation thereto are specified in the schedule to this certificate and the documents therein referred to. [8] UL International Demko A/S certifies that this equipment has been found to comply with the Essential Health and Safety Requirements that relate to the design of Category 3 equipment, which is intended for use in potentially explosive atmospheres. These Essential Health and Safety Requirements are given in Annex II to the European Union Directive 94/9/EC of 23 March 1994. Reed Switches Littelfuse Inc. 612 E Lake St. Lake Mills, WI 53551, USA The examination and test results are recorded in confidential report number: [9] 4786574151 Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the schedule of this certificate, has been assessed by reference to Standards: EN 60079-0:2012+A11:2013 EN 60079-15:2010 [10] The sign "U" placed after the certificate number indicates that this certificate must not be mistaken for a certificate intended for an equipment or protective system. This partial certification may be used as a basis for certification of an equipment or protective. [11] This Type examination certificate relates only to the design of the specified component, and not to specific items of equipment subsequently manufactured. [12] The marking of the equipment or protective system shall include the following: II 3 G Certification Manager Jan-Erik Storgaard Ex nC IIC Gc This is to certify that the sample(s) of the Equipment described herein (“Certified Equipment”) has been investigated and found in compliance with the Standard(s) indicated on this Certificate, in accordance with the ATEX Equipment Certification Program Requirements. This certificate and test results obtained apply only to the equipment sample(s) submitted by the Manufacturer. UL did not select the sample(s) or determine whether the sample(s) provided were representative of other manufactured equipment. UL has not established FollowUp Service or other surveillance of the equipment. The Manufacturer are solely and fully responsible for conformity of all equipment to all applicable Standards, specifications, requirements or Directives. The test results may not be used, in whole or in part, in any other document without UL’s prior written approval. Date of issue: 2015-03-16 Certification Body 00-IC-F0061 – Issue 8.0 UL International Demko A/S, Borupvang 5A, 2750 Ballerup, Denmark Tel. +45 44 85 65 65, [email protected], www.ul.com This certificate may only be reproduced in its entirety and without any change, schedule included. Page 1 of 5 Schedule TYPE EXAMINATION CERTIFICATE No. DEMKO 14 ATEX 1393U Rev. 0 [13] [14] Report: 4786574151 [15] Description of Component: The below components are hermetically sealed magnetically operated reed switches that are suitable for use in industrial hazardous location applications. DRR-129 MASM-14x MDSR-7 MLRR-3 59165 MARR-5 FLEX-14 MDCG-4 MDSR-10 MLRR-4 59166 MDSM-DTx HA15-2 MDRR-DT MISM-3V1x MLSM-3x 59170 MITI-7 MACD-14 MDSM-4x MITI-3V1 MLSM-4x 59045-1 MRPR-8 MATE-12 MDSM-10x MISM-7x MRPR-3 59050-1 59050-2 The “x” in the nomenclature can be either B or R and it indicates packaging type. B is for bulk packaging while R is tape and reel. These reed switches can be single pole, single throw or single pole, double throw type; glass or overmolded glass; axial leads, radial leads or crimped axial leads for surface mounting as shown in the below table: Part Number DRR-129 FLEX-14 HA15-2 MACD-14 MATE-12 MARR-5 MASM-14x MDCG-4 MDRR-DT MDSM-4x MDSM-10x MDSM-DTx MDSR-7 MDSR-10 MISM-3V1x MITI-3V1 MISM-7x MITI-7 MLRR-3 MLRR-4 MLSM-3x MLSM-4x MRPR-3 MRPR-8 59165 59166 59170 59045-1 59050-1 59050-2 Switch Type SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPDT-CO SPST-NO SPST-NO SPDT-CO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO Package Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Overmolded Overmolded Overmolded Overmolded Overmolded Overmolded Terminals Axial Leads Axial Leads Axial Leads Axial Leads Axial Leads Axial Leads Crimped Axial Leads – Surface Mount Axial Leads Axial Leads Crimped Axial Leads – Surface Mount Crimped Axial Leads – Surface Mount Crimped Axial Leads – Surface Mount Axial Leads Axial Leads Crimped Axial Leads – Surface Mount Axial Leads Crimped Axial Leads – Surface Mount Axial Leads Axial Leads Axial Leads Crimped Axial Leads – Surface Mount Crimped Axial Leads – Surface Mount Axial Leads Axial Leads Axial Leads and SMD Leads and Crimped Axial Leads – Surface Mount Leads and Crimped Axial Leads – Surface Mount Radial Leads Radial Leads Radial Leads Temperature range: The service temperature range is -40C to +125 C. 00-IC-F0061 – Issue 8.0 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 5 Schedule TYPE EXAMINATION CERTIFICATE No. DEMKO 14 ATEX 1393U Rev. 0 [13] [14] Report: 4786574151 Electrical data Part Number DRR-129 Maximum Wattage (W) 50 FLEX-14 10 HA15-2 MACD-14 20 10 10 10 MATE-12 10 MARR-5 10 MASM-14x 10 MDCG-4 10 MDRR-DT MDSM-4x 10 10 MDSM-10x MDSM-DTx MDSR-7 10 10 10 MDSR-10 10 MISM-3V1x MISM-7x MITI-7 MLRR-3 MLRR-4 10 10 10 20 20 AC Voltage (V) 125 250 125 140 14 265 100 265 125 140 14 125 120 140 14 120 265 125 140 14 125 140 14 120 125 125 140 14 120 125 125 125 120 140 14 125 140 14 120 120 120 125 125 MLSM-3x MLSM-4x 20 GP 125 125 00-IC-F0061 – Issue 8.0 Current (A) 0.4 0.2 0.35 0.072 0.5 0.075 0.354 0.3 0.35 0.072 0.5 0.354 0.1 0.5 0.1 0.354 0.35 0.072 0.5 0.35 0.5 0.5 0.35 0.35 0.5 0.5 0.354 0.35 0.354 0.1 0.5 0.354 0.072 0.5 0.25 0.25 0.25 0.707 0.707 0.707 0.707 DC Voltage (V) - Current (A) - 200 0.5 200 200 200 0.5 0.4 0.5 200 50 0.5 0.25 50 1000 200 0.25 0.5 0.5 200 24 1 0.5 175 200 24 0.35 1 0.5 200 175 200 50 0.5 0.35 0.5 0.25 200 0.5 170 170 170 200 200 24 50 200 200 24 50 0.25 0.25 0.25 1 1 0.25 0.25 1 1 0.25 0.25 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 3 of 5 Schedule TYPE EXAMINATION CERTIFICATE No. DEMKO 14 ATEX 1393U Rev. 0 [13] [14] Report: 4786574151 Part Number Maximum Wattage (W) 50 AC Voltage (V) 120 Current (A) 0.5 50 120 240 24 120 0.1 0.05 1.125 0.5 59165 59166 59170 59045-1 10 10 10 10 240 120 265 48 140 140 140 140 0.25 0.5 0.189 0.707 0.35 0.35 0.35 0.35 59050-1 10 140 59050-2 20 265 MRPR-3 MRPR-8 [16] DC Voltage (V) 200 24 - Current (A) 0.001 1.5 - 200 24 250 0.001 1.5 1 200 200 200 200 0.5 0.5 0.5 0.5 0.35 200 0.5 0.35 200 0.5 Descriptive Documents. The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate. 00-IC-F0061 – Issue 8.0 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 4 of 5 Schedule TYPE EXAMINATION CERTIFICATE No. DEMKO 14 ATEX 1393U Rev. 0 [13] [14] Report: 4786574151 [17] Schedule of limitations: These devices shall be used within their electrical ratings as indicated under “Electrical Data”. These devices shall be mounted within a suitable ATEX enclosure in accordance with spacing, mounting, and segregation requirements of the ultimate product standard. These devices are intended for factory wiring only (terminations are not suitable for field wiring). No determination of the strength of the glass envelope has been made. Each end-use application shall determine the adequacy of the glass envelope. The temperature test was conducted on these devices to determine the appropriate service temperature. Devices were tested at a room ambient, 22C and maximum temperature measured was as shown in the table below. If used in higher ambient, the difference between the higher ambient and 22C shall be added to the maximum temperatures measured below. Temperature Test shall be considered in end product evaluation. Model Models Maximum Temp. Adjusted to Tested Covered Measured in room 40C MDSR-10 MATE-12 Adjusted to 85C Adjusted to 125C ambient(22C) MDSR-7 MISM-3V1x MDSM-10x 26C 44C 89C 129C 26C 44C 89C 129C 35.2C 53.2C 98.2C 138.2C 23.7C 41.4C 86.4C 126.4C MITI-7x MISM-7x FLEX-14 MDCG-4 MDRR-DT MDSM-4x MDSM-DTx 59165 59166 59170 59045-1 59050-1 MACD-14 MASM-14x MRPR-3 HA15-2 MLRR-4 MLRR-3 MARR-5 MLSM-4x MLSM-3x 59050-2 MRPR-8 DRR-129 [18] - Essential Health and Safety Requirements Met by compliance with the standards EN 60079-0: 2012+A11:2013 and EN 60079-15: 2010. 00-IC-F0061 – Issue 8.0 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 5 of 5