omron.com

Air Clean Unit
ZN-A
CSM_ZN-A_DS_E_2_1
The ZN series is even thinner and
sports improved air volume.
These products enable cleaning that
is both fast and flexible.
• Three sizes are available to match various sizes of clean
booths.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read “Safety Precautions” on
page 4.
Ordering Information
Air Clean Units
Air Clean Units
Appearance
Application
Power supply
Model
250 × 250 mm
ZN-A2502D
410 × 410 mm
ZN-A4105D
24 VDC
ZN-A6112
610 × 610 mm
ZN-A6112P *
*This type is equipped with a clog detection function.
Accessories
Application
For 250 × 250 mm
Replacement HEPA Filters
For 410 × 410 mm
For 610 × 610 mm
For 250 × 250 mm
For 410 × 410 mm
Replacement Pre-filters
For 610 × 610 mm
Model
Qty.
ZN9-AHP25
ZN9-AHP41
ZN9-AHP61
ZN9-APF25
ZN9-APF41
ZN9-APF61
1
1
1
2
1
1
Ionizers Units
Ionizers
Appearance
Application
Power supply
Model
250 × 250 mm
ZN-J25A
Supplied from the Air Clean Unit.
410 × 410 mm
ZN-J41A
Accessories
Replacement Discharge Needles
Model
Qty.
ZN9-JH04
4 per pack
Single-sided Connector Cables (for DC power supply or I/O connection)
Cable length
2m
Model
Qty.
ZN9-JC02
1
1
ZN-A
Ratings and Specifications
Air Clean Units
Item
Model
Air outlet dimension
ZN-A2502D
225 × 205 mm
ZN-A4105D
360 × 360 mm
Main filter/Removal rate
HEPA filter/ 99.99% of particles 0.3-μm and larger
Air volume (m3/min)
0.3 to 1.8 m3/min (typical)
Power supply voltage
24 VDC ±10%, Ripple (p-p): 10% max.
Current consumption
Airflow level 5: 2.1 A max.
(RMS value)
(Peak: 3 A)
5 levels
Airflow levels
1.0 to 5.0 m3/min (typical)
Airflow level 5: 3.5 A max.
(RMS value)
(Peak: 5.5 A)
• Settable by button operation
• Settable by serial (RS-422 or RS-485 *1)
communications
ZN-A6112
ZN-A6112P
578 × 568 mm
4 to 12 m3/min (typical)
Airflow level 5:
24 VDC: 4.3 A max. (RMS value) (Peak: 8 A)
5 levels
• Settable by button operation
• Settable by serial (RS-422 or RS-485 *1)
communications
• Settable by ON/OFF signal input
(3 levels) *2
Running noise
Airflow level 3: 53 dB (typical)
Fan motor
Compact DC brushless
centrifugal blower x 2
Indicators
Operating status: Green/Red
Air volume: Blue
Filter clogging detection
Yes
No
Alarm output 1: Alarm output 1 turns OFF when one of
the following events occurs.
(Normally alarm output 1 is ON.)
(Check indicator to find out which event
occurred.)
• Filter is clogged.
• Fan error
• Cleaning alarm for discharge needle
(when ZN-J-series Ionizer (sold
separately) is connected)
• Discharge error (when ZN-J-series
Ionizer (sold separately) is connected)
Alarm output 2: Enabled only when ZN-J-series Ionizer
(sold separately) is connected.
• Alarm output 2 turns OFF to indicate
that cleaning is necessary for ZN-J
Series discharge needles.
(Normally alarm output 2 is ON.)
Fan operation alarm output
Alarm output OFF in below cases (ON during normal
operation)
• Fan not rotating (Including when power is
OFF or on standby)
• Trouble
• Clogged filter (ZN-A6112P only)
External output
Airflow level 3: 53 dB (typical)
DC brushless turbo fan x 1 DC brushless turbo fan x 1
Yes
30 VDC, 50 mA max.
Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA.
Applicable Ionizer Unit
(Optional)
ZN-J25A
Ambient temperature
range
Operating and storage: 0 to 40°C (with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Applicable
contamination degree
Pollution degree 2
Material
Top: Antistatic plastic, bottom: SECC
Top: ABS resin, HEPA filter frame: aluminum
Dimensions (mm)
250 × 250 × 97.5 mm
(W × D × H)
714.4 × 654.4 × 174.3 mm (W × D × H)
(Height from attachment surface: 117.3)
Weight (Packaged)
Approx. 2 kg (Approx. 3.3 kg) Approx. 5.2 kg (Approx. 8.6 kg)
Approx. 12.5 kg (Approx. 17 kg)
Accessories
Instruction Sheet, Sealing parts, Mounting screws,
I/O connector (XW4B-06B1-H1)
Instruction Sheet, Sealing parts, Mounting screws,
I/O connector (XW4B-10B1-H1)
ZN-J41A
410 × 410 × 129.5 mm
(W × D × H)
None
*1. Use the dip switches on the unit surface (connector surface) to switch between RS-422 and RS-485.
*2. Contact input: 5 mA max. ON current. Use input device of 30 V or higher withstand voltage.
2
ZN-A
Ionizer
Item
Model
ZN-J25A
ZN-J41A
Applicable Air Clean
Units
ZN-A2502D
Power supply voltage
24 VDC ±10%, Ripple (p-p): 10% max.
Current consumption
300 mA max
Discharge voltage
±7 kV max
Discharge method
Variable DC discharge
Static electricity removal
time (typical) *1
5 s max.
Ion balance (typical) *2
±30 V max.
Indicators
Power (green), Cleaning notice (orange flashing), Cleaning alarm (orange), High voltage error (red)
External output
High voltage error, cleaning outputs: Output from photo MOS relay (30V DC, 300 mA max.)
Functions
Manual adjustment of ion balance, cleaning required detection, high voltage detection
Ambient temperature
range
Operating and storage: 0 to 40°C (with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 65% (with no condensation)
Materials
Unit: ABS, Discharge needles: Tungsten
Dimensions (mm)
248 × 310 × 45 mm (W × D × H)
408 × 470 × 45 mm (W × D × H)
Weight (Packaged)
Approx. 0.6 kg (Approx. 1.4 kg)
Approx. 1.5 kg (Approx. 2.7 kg)
Accessories
Instruction Sheet
Sealing parts
Mounting screws
Connector cable for Air Clean Unit
English warning label
ZN-4105D
*1. Measurement conditions:
Distance: 300 mm
Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet
Discharging from ±1000 V to ±100 V with a Charge Plate Monitor (150 × 150 mm, 20 pF)
Temperature: 18 to 28°C, Humidity: 35% to 55%
Performance may not be satisfied if gases such as from solvents are in the measurement area.
*2. Measurement conditions:
Distance: 300 mm
Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet
Measured for 10 sec by a charge plate monitor (150 × 150mm, 20pF)
Temperature: 18 to 28°C, Humidity: 35% to 55%
Performance may not be satisfied if gases such as from solvents are in the measurement area.
3
ZN-A
Safety Precautions
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precaution for Correct Use
Do not use the product in ambient atmospheres or environments that
exceed the ratings.
For technical information and product FAQs,
refer to the “Technical Guide” on your OMRON
website.
4
ZN-A
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Air Clean Units
ZN-A2502D
250
97.5
45
160
28
250 276
205.6 220
Four, M4 screws, depth: 17
226.6
ON/OFF switch
Air volume switch
Operation indicators
Operation indicators
Air volume level indicators
ZN-A4105D
15
417
410
129.5
436 410
380
360
15
380 360
Air volume switch
ON/OFF switch
Four, M5 screws, depth: 20
Operation indicators
Operation indicators
Air volume level indicators
ZN-A6112/A6112P
694
(677)
500
Fall prevention hook fixation part
57 117.3
714.4
Air volume switch
Air volume level indicators
634 500
Alarm indicator
654.4
ON/OFF switch
Power indicator
8-M6 mounting holes
6.5-dia. spot facing, depth: 3.5
Fall prevention hook attachment hole
Power supply cable
Eight, 8-dia. mounting holes
694±1
682±1
500±1
When the unit is installed close to a wall, ensure that
there is sufficient space (approximately 130 mm) to pull
out the power cable.
R
4-
3
m
ax
.
634±1
500±1
621±1
Panel Cut Dimensions
5
ZN-A
Ionizers
ZN-J25A
Ion balance adjustment button
Mounting Hole and Panel Cut Dimensions
Eight, 5-dia. mounting holes (through-holes)
Power indicator
(green, lit)
Cleaning notification
indicator (orange, flashing) 248
Cleaning alarm
70
indicator (orange, lit)
High voltage error
indicator (red, lit)
Power input/
signal output connector
210
210
210
Ground terminal
25.50
160±0.2
220±0.2
210
Power switch
160±0.2
220±0.2
220
Discharge needles (4 locations)
Eight, 5-dia. holes
252
45
33
6
(3.3)
310
ZN-J41A
Mounting Hole and Panel Cut Dimensions
Twelve, 6-dia. holes
380
240
Power indicator
(green, lit)
Cleaning notification
indicator (orange, flashing)
Cleaning alarm
408
indicator (orange, lit)
70
High voltage error
indicator (red, lit)
Ion balance adjustment
button
Power switch
Twelve, 6-dia. mounting holes
(through-holes)
Power input/
signal output connector
240
Ground terminal
360
380
380±0.2
360
240±0.2
Discharge needles
(4 locations)
65.5
45
380±0.2
360
240±0.2
33
360
412
(3.3)
6
470
6
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2013.6
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2013 All Right Reserved.