Air Clean Unit ZN-A CSM_ZN-A_DS_E_2_1 The ZN series is even thinner and sports improved air volume. These products enable cleaning that is both fast and flexible. • Three sizes are available to match various sizes of clean booths. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read “Safety Precautions” on page 4. Ordering Information Air Clean Units Air Clean Units Appearance Application Power supply Model 250 × 250 mm ZN-A2502D 410 × 410 mm ZN-A4105D 24 VDC ZN-A6112 610 × 610 mm ZN-A6112P * *This type is equipped with a clog detection function. Accessories Application For 250 × 250 mm Replacement HEPA Filters For 410 × 410 mm For 610 × 610 mm For 250 × 250 mm For 410 × 410 mm Replacement Pre-filters For 610 × 610 mm Model Qty. ZN9-AHP25 ZN9-AHP41 ZN9-AHP61 ZN9-APF25 ZN9-APF41 ZN9-APF61 1 1 1 2 1 1 Ionizers Units Ionizers Appearance Application Power supply Model 250 × 250 mm ZN-J25A Supplied from the Air Clean Unit. 410 × 410 mm ZN-J41A Accessories Replacement Discharge Needles Model Qty. ZN9-JH04 4 per pack Single-sided Connector Cables (for DC power supply or I/O connection) Cable length 2m Model Qty. ZN9-JC02 1 1 ZN-A Ratings and Specifications Air Clean Units Item Model Air outlet dimension ZN-A2502D 225 × 205 mm ZN-A4105D 360 × 360 mm Main filter/Removal rate HEPA filter/ 99.99% of particles 0.3-μm and larger Air volume (m3/min) 0.3 to 1.8 m3/min (typical) Power supply voltage 24 VDC ±10%, Ripple (p-p): 10% max. Current consumption Airflow level 5: 2.1 A max. (RMS value) (Peak: 3 A) 5 levels Airflow levels 1.0 to 5.0 m3/min (typical) Airflow level 5: 3.5 A max. (RMS value) (Peak: 5.5 A) • Settable by button operation • Settable by serial (RS-422 or RS-485 *1) communications ZN-A6112 ZN-A6112P 578 × 568 mm 4 to 12 m3/min (typical) Airflow level 5: 24 VDC: 4.3 A max. (RMS value) (Peak: 8 A) 5 levels • Settable by button operation • Settable by serial (RS-422 or RS-485 *1) communications • Settable by ON/OFF signal input (3 levels) *2 Running noise Airflow level 3: 53 dB (typical) Fan motor Compact DC brushless centrifugal blower x 2 Indicators Operating status: Green/Red Air volume: Blue Filter clogging detection Yes No Alarm output 1: Alarm output 1 turns OFF when one of the following events occurs. (Normally alarm output 1 is ON.) (Check indicator to find out which event occurred.) • Filter is clogged. • Fan error • Cleaning alarm for discharge needle (when ZN-J-series Ionizer (sold separately) is connected) • Discharge error (when ZN-J-series Ionizer (sold separately) is connected) Alarm output 2: Enabled only when ZN-J-series Ionizer (sold separately) is connected. • Alarm output 2 turns OFF to indicate that cleaning is necessary for ZN-J Series discharge needles. (Normally alarm output 2 is ON.) Fan operation alarm output Alarm output OFF in below cases (ON during normal operation) • Fan not rotating (Including when power is OFF or on standby) • Trouble • Clogged filter (ZN-A6112P only) External output Airflow level 3: 53 dB (typical) DC brushless turbo fan x 1 DC brushless turbo fan x 1 Yes 30 VDC, 50 mA max. Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA. Applicable Ionizer Unit (Optional) ZN-J25A Ambient temperature range Operating and storage: 0 to 40°C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Applicable contamination degree Pollution degree 2 Material Top: Antistatic plastic, bottom: SECC Top: ABS resin, HEPA filter frame: aluminum Dimensions (mm) 250 × 250 × 97.5 mm (W × D × H) 714.4 × 654.4 × 174.3 mm (W × D × H) (Height from attachment surface: 117.3) Weight (Packaged) Approx. 2 kg (Approx. 3.3 kg) Approx. 5.2 kg (Approx. 8.6 kg) Approx. 12.5 kg (Approx. 17 kg) Accessories Instruction Sheet, Sealing parts, Mounting screws, I/O connector (XW4B-06B1-H1) Instruction Sheet, Sealing parts, Mounting screws, I/O connector (XW4B-10B1-H1) ZN-J41A 410 × 410 × 129.5 mm (W × D × H) None *1. Use the dip switches on the unit surface (connector surface) to switch between RS-422 and RS-485. *2. Contact input: 5 mA max. ON current. Use input device of 30 V or higher withstand voltage. 2 ZN-A Ionizer Item Model ZN-J25A ZN-J41A Applicable Air Clean Units ZN-A2502D Power supply voltage 24 VDC ±10%, Ripple (p-p): 10% max. Current consumption 300 mA max Discharge voltage ±7 kV max Discharge method Variable DC discharge Static electricity removal time (typical) *1 5 s max. Ion balance (typical) *2 ±30 V max. Indicators Power (green), Cleaning notice (orange flashing), Cleaning alarm (orange), High voltage error (red) External output High voltage error, cleaning outputs: Output from photo MOS relay (30V DC, 300 mA max.) Functions Manual adjustment of ion balance, cleaning required detection, high voltage detection Ambient temperature range Operating and storage: 0 to 40°C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 65% (with no condensation) Materials Unit: ABS, Discharge needles: Tungsten Dimensions (mm) 248 × 310 × 45 mm (W × D × H) 408 × 470 × 45 mm (W × D × H) Weight (Packaged) Approx. 0.6 kg (Approx. 1.4 kg) Approx. 1.5 kg (Approx. 2.7 kg) Accessories Instruction Sheet Sealing parts Mounting screws Connector cable for Air Clean Unit English warning label ZN-4105D *1. Measurement conditions: Distance: 300 mm Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet Discharging from ±1000 V to ±100 V with a Charge Plate Monitor (150 × 150 mm, 20 pF) Temperature: 18 to 28°C, Humidity: 35% to 55% Performance may not be satisfied if gases such as from solvents are in the measurement area. *2. Measurement conditions: Distance: 300 mm Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet Measured for 10 sec by a charge plate monitor (150 × 150mm, 20pF) Temperature: 18 to 28°C, Humidity: 35% to 55% Performance may not be satisfied if gases such as from solvents are in the measurement area. 3 ZN-A Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precaution for Correct Use Do not use the product in ambient atmospheres or environments that exceed the ratings. For technical information and product FAQs, refer to the “Technical Guide” on your OMRON website. 4 ZN-A (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Air Clean Units ZN-A2502D 250 97.5 45 160 28 250 276 205.6 220 Four, M4 screws, depth: 17 226.6 ON/OFF switch Air volume switch Operation indicators Operation indicators Air volume level indicators ZN-A4105D 15 417 410 129.5 436 410 380 360 15 380 360 Air volume switch ON/OFF switch Four, M5 screws, depth: 20 Operation indicators Operation indicators Air volume level indicators ZN-A6112/A6112P 694 (677) 500 Fall prevention hook fixation part 57 117.3 714.4 Air volume switch Air volume level indicators 634 500 Alarm indicator 654.4 ON/OFF switch Power indicator 8-M6 mounting holes 6.5-dia. spot facing, depth: 3.5 Fall prevention hook attachment hole Power supply cable Eight, 8-dia. mounting holes 694±1 682±1 500±1 When the unit is installed close to a wall, ensure that there is sufficient space (approximately 130 mm) to pull out the power cable. R 4- 3 m ax . 634±1 500±1 621±1 Panel Cut Dimensions 5 ZN-A Ionizers ZN-J25A Ion balance adjustment button Mounting Hole and Panel Cut Dimensions Eight, 5-dia. mounting holes (through-holes) Power indicator (green, lit) Cleaning notification indicator (orange, flashing) 248 Cleaning alarm 70 indicator (orange, lit) High voltage error indicator (red, lit) Power input/ signal output connector 210 210 210 Ground terminal 25.50 160±0.2 220±0.2 210 Power switch 160±0.2 220±0.2 220 Discharge needles (4 locations) Eight, 5-dia. holes 252 45 33 6 (3.3) 310 ZN-J41A Mounting Hole and Panel Cut Dimensions Twelve, 6-dia. holes 380 240 Power indicator (green, lit) Cleaning notification indicator (orange, flashing) Cleaning alarm 408 indicator (orange, lit) 70 High voltage error indicator (red, lit) Ion balance adjustment button Power switch Twelve, 6-dia. mounting holes (through-holes) Power input/ signal output connector 240 Ground terminal 360 380 380±0.2 360 240±0.2 Discharge needles (4 locations) 65.5 45 380±0.2 360 240±0.2 33 360 412 (3.3) 6 470 6 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2013.6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2013 All Right Reserved.