G3VM-51PR MOS FET Relays Smallest Class in market, USOP Package MOS FET Relays is designed to exhibit a fast rise time and reduce signal degradation. • ERT(Equivalent Rise Time): 40 ps (typ.), 90 ps (max) • Dielectric strength of 500Vrms between I/O. RoHS Compliant Note: The actual product is marked differently from the image shown here. Refer to "Common Precautions". ■Application Examples ■Terminal Arrangement/Internal Connections • Communication • Semiconductor test OMRON mark • Data loggers • Test & measurement Model name 5P0 equipment equipment LOT No. 103 equipment Note: The actual product is marked differently from the image shown here. ■List of Models Package type Contact form 1a (SPST-NO) USOP4 Load voltage (peak value) (See note.) Terminals Minimum package quantity Model Number per tape & reel − G3VM-51PR Surface-mounting terminals 50V G3VM-51PR (TR05) 500 G3VM-51PR (TR) 1,500 Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs. 2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. 3. The AC peak and DC value is given for the load voltages. ■Absolute Maximum Ratings (Ta = 25°C) Item LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Output G 3 V M I 5 1 P R Input U S O P Continuous load current (AC peak/DC) ON current reduction rate Pulse ON current Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol Rating Unit IF 50 mA Measurement conditions ΔIF/°C −0.5 mA/°C VR 5 V °C TJ 125 VOFF 50 V IO 300 mA ΔIO/°C −3.0 mA/°C lop 900 mA TJ 125 °C VI-O 500 Vrms Ta≥25°C Ta≥25°C t=100ms, Duty=1/10 Note: 1.The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. AC for 1 min Ta −40 ~ +85 °C Tstg −40 ~ +125 °C With no icing or condensation − 260 °C 10s With no icing or condensation ■Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum Unit Measurement conditions VF 1.0 1.15 1.3 V IF=10mA Reverse current IR − − 10 μA VR=5V Capacity between terminals CT − 15 − pF V=0, f=1MHz Trigger LED forward current IFT − 0.5 3 mA Maximum resistance with output ON RON − 1 1.5 Ω IF=5mA, IO=300mA, t<1s Current leakage when the relay is open ILEAK − − 1 nA VOFF=50V Capacity between terminals COFF − 12 − pF V=0, f=100MHz, t<1s Capacity between I/O terminals CI-O − 0.4 − pF f=1MHz, VS=0V Insulation resistance between I/O terminals RI-O 1000 − − MΩ VI-O=500VDC, ROH≤60% Turn-ON time tON − 0.2 0.5 ms Turn-OFF time tOFF − 0.1 0.4 ms IF=5mA, RL=200Ω, VDD=20V (See note 2.) Equivalent rise time ERT − 40 90 ps Input LED forward voltage Output 1 Note: 2.Turn-ON and Turn-OFF Times IF 1 4 2 3 RL IO=100mA IF=5mA, VDD=0.25V, Tr(in)=25ps (See Note.3) VDD VOUT IF VOUT 10% 90% t ON t OFF Note: 3.ERT (Equivalent Rise Time) ERT=√(trout2−trin2) 250mV 250mV 90% 90% 10% 10% 0V 0V trin trout Input waveform Output waveform G3VM-51PR MOS FET Relays ■Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum VDD − − 40 V IF 5 7.5 20 mA Load voltage (AC peak/DC) Operating LED forward current Unit Continuous load current (AC peak/DC) IO − − 300 mA Ambient operating temperature Ta −20 − 65 °C ■Engineering Data IF - VF IO - Ta IF - Ta 50 40 30 20 400 LED forward current IF (mA) 60 Continuous load current IO (mA) LED forward current IF (mA) LED forward current vs. LED forward voltage Continuous load current vs. Ambient temperature LED forward current vs. Ambient temperature 300 200 100 Ta = 25°C 10 1 100 10 0 -40 -20 0 20 40 60 80 0 -40 100 -20 0 20 Ambient temperature Ta (°C) Ta = 25°C IF=5mA t<1s 100 0 -100 -0.1 0 0.1 0.2 0.3 Io=300mA IF=5mA t<1s 2 1 0 -40 0.4 0 20 40 60 80 1 -40 100 Turn ON, Turn OFF time vs. Ambient temperature Ta=25°C t OFF 100 t ON 10 10 100 LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (μs) Turn ON, Turn OFF time tON, tOFF (μs) RL=200Ω 1 Io=100mA t<1s -20 0 20 40 60 80 100 Ambient temperature Ta (°C) U S O P Current leakage vs. Load voltage ILEAK - VOFF tON, tOFF - Ta VDD=20V 1000 2 Ambient temperature Ta (°C) tON, tOFF - IF 10000 1.6 0 -20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 1.4 LED forward voltage VF (V) Current leakage ILEAK (pA) -0.2 1.2 IFT - Ta 3 -300 -0.3 1 Trigger LED forward current vs. Ambient temperature -200 -400 -0.4 0.1 0.8 100 Trigger LED forward current IFT (mA) On-state resistance RON (Ω) Continuous load current IO (mA) 80 RON - Ta IO - VON 400 200 60 On-state resistance vs. Ambient temperature Continuous load current vs. On-state voltage 300 40 Ambient temperature Ta (°C) 1000 t ON 100 t OFF 50 Ta = 25°C 40 G 3 V M I 5 1 P R 30 20 VDD=20V 10 RL=200Ω IF=5mA 10 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 0 0 10 20 30 40 50 Load voltage VOFF (v) Output terminal capacitance COFF/COFF(ov) vs. Load voltage Output terminal capacitance COFF/COFF(ov) COFF - VOFF 1.2 Ta = 25°C 1 0.8 0.6 0.4 0.2 0 0 10 20 30 40 Load voltage VOFF (v) ■Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Apperance/Dimensions USOP4 ■Appearance USOP (Ultra Small Outline Package) USOP4 5P0 Model name OMRON mark 103 LOT No. Note: The actual product is marked differently from the image shown here. ■Dimensions 5P0 (Unit: mm) Surface-mounting Terminals 103 Actual Mounting Pad Dimensions Weight: 0.03g (Recommended Value, Top View) 3.25 2.05 0.85 2.9 0.15 1.65 (0.4) 1.27 2.2 0.8 0.2 2.85 1.27 (0.35) Note: The actual product is marked differently from the image shown here. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K209-E1-02 1112(0912)(O)