OMRON G3VM-51PR

G3VM-51PR
MOS FET Relays
Smallest Class in market, USOP
Package MOS FET Relays is designed to
exhibit a fast rise time and reduce signal
degradation.
• ERT(Equivalent Rise Time): 40 ps (typ.), 90 ps (max)
• Dielectric strength of 500Vrms between I/O.
RoHS Compliant
Note: The actual product is marked differently from the
image shown here.
Refer to "Common Precautions".
■Application Examples
■Terminal Arrangement/Internal Connections
• Communication
• Semiconductor test
OMRON mark
• Data loggers
• Test & measurement
Model name
5P0
equipment
equipment
LOT No.
103
equipment
Note: The actual product is marked differently from the image shown here.
■List of Models
Package type
Contact form
1a
(SPST-NO)
USOP4
Load voltage (peak value)
(See note.)
Terminals
Minimum package quantity
Model
Number per tape & reel
−
G3VM-51PR
Surface-mounting terminals
50V
G3VM-51PR (TR05)
500
G3VM-51PR (TR)
1,500
Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs.
2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions.
3. The AC peak and DC value is given for the load voltages.
■Absolute Maximum Ratings (Ta = 25°C)
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Output
G
3
V
M
I
5
1
P
R
Input
U
S
O
P
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
Rating
Unit
IF
50
mA
Measurement conditions
ΔIF/°C
−0.5
mA/°C
VR
5
V
°C
TJ
125
VOFF
50
V
IO
300
mA
ΔIO/°C
−3.0
mA/°C
lop
900
mA
TJ
125
°C
VI-O
500
Vrms
Ta≥25°C
Ta≥25°C
t=100ms, Duty=1/10
Note: 1.The dielectric strength between the
input and output was checked by
applying voltage between all pins as
a group on the LED side and all pins
as a group on the light-receiving
side.
AC for 1 min
Ta
−40 ~ +85
°C
Tstg
−40 ~ +125
°C
With no icing or condensation
−
260
°C
10s
With no icing or condensation
■Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum
Unit
Measurement conditions
VF
1.0
1.15
1.3
V
IF=10mA
Reverse current
IR
−
−
10
μA
VR=5V
Capacity between terminals
CT
−
15
−
pF
V=0, f=1MHz
Trigger LED forward current
IFT
−
0.5
3
mA
Maximum resistance with output ON
RON
−
1
1.5
Ω
IF=5mA, IO=300mA, t<1s
Current leakage when the relay is
open
ILEAK
−
−
1
nA
VOFF=50V
Capacity between terminals
COFF
−
12
−
pF
V=0, f=100MHz, t<1s
Capacity between I/O terminals
CI-O
−
0.4
−
pF
f=1MHz, VS=0V
Insulation resistance between I/O
terminals
RI-O
1000
−
−
MΩ
VI-O=500VDC, ROH≤60%
Turn-ON time
tON
−
0.2
0.5
ms
Turn-OFF time
tOFF
−
0.1
0.4
ms
IF=5mA, RL=200Ω,
VDD=20V (See note 2.)
Equivalent rise time
ERT
−
40
90
ps
Input
LED forward voltage
Output
1
Note: 2.Turn-ON and Turn-OFF Times
IF
1
4
2
3
RL
IO=100mA
IF=5mA, VDD=0.25V,
Tr(in)=25ps (See Note.3)
VDD
VOUT
IF
VOUT
10%
90%
t ON
t OFF
Note: 3.ERT (Equivalent Rise Time)
ERT=√(trout2−trin2)
250mV
250mV
90%
90%
10%
10%
0V
0V
trin
trout
Input waveform
Output waveform
G3VM-51PR
MOS FET Relays
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
VDD
−
−
40
V
IF
5
7.5
20
mA
Load voltage (AC peak/DC)
Operating LED forward current
Unit
Continuous load current (AC peak/DC)
IO
−
−
300
mA
Ambient operating temperature
Ta
−20
−
65
°C
■Engineering Data
IF - VF
IO - Ta
IF - Ta
50
40
30
20
400
LED forward current IF (mA)
60
Continuous load current IO (mA)
LED forward current IF (mA)
LED forward current vs.
LED forward voltage
Continuous load current vs.
Ambient temperature
LED forward current vs.
Ambient temperature
300
200
100
Ta = 25°C
10
1
100
10
0
-40
-20
0
20
40
60
80
0
-40
100
-20
0
20
Ambient temperature Ta (°C)
Ta = 25°C
IF=5mA
t<1s
100
0
-100
-0.1
0
0.1
0.2
0.3
Io=300mA
IF=5mA
t<1s
2
1
0
-40
0.4
0
20
40
60
80
1
-40
100
Turn ON, Turn OFF time vs.
Ambient temperature
Ta=25°C
t OFF
100
t ON
10
10
100
LED forward current IF (mA)
Turn ON, Turn OFF time tON, tOFF (μs)
Turn ON, Turn OFF time tON, tOFF (μs)
RL=200Ω
1
Io=100mA
t<1s
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
U
S
O
P
Current leakage vs. Load voltage
ILEAK - VOFF
tON, tOFF - Ta
VDD=20V
1000
2
Ambient temperature Ta (°C)
tON, tOFF - IF
10000
1.6
0
-20
On-state voltage VON (V)
Turn ON, Turn OFF time vs.
LED forward current
1.4
LED forward voltage VF (V)
Current leakage ILEAK (pA)
-0.2
1.2
IFT - Ta
3
-300
-0.3
1
Trigger LED forward current vs.
Ambient temperature
-200
-400
-0.4
0.1
0.8
100
Trigger LED forward current IFT (mA)
On-state resistance RON (Ω)
Continuous load current IO (mA)
80
RON - Ta
IO - VON
400
200
60
On-state resistance vs.
Ambient temperature
Continuous load current vs.
On-state voltage
300
40
Ambient temperature Ta (°C)
1000
t ON
100
t OFF
50
Ta = 25°C
40
G
3
V
M
I
5
1
P
R
30
20
VDD=20V
10
RL=200Ω
IF=5mA
10
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
0
0
10
20
30
40
50
Load voltage VOFF (v)
Output terminal capacitance
COFF/COFF(ov) vs. Load voltage
Output terminal capacitance COFF/COFF(ov)
COFF - VOFF
1.2
Ta = 25°C
1
0.8
0.6
0.4
0.2
0
0
10
20
30
40
Load voltage VOFF (v)
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Apperance/Dimensions
USOP4
■Appearance
USOP (Ultra Small Outline Package)
USOP4
5P0
Model name
OMRON mark
103
LOT No.
Note: The actual product is marked differently from the image shown here.
■Dimensions
5P0
(Unit: mm)
Surface-mounting Terminals
103
Actual Mounting Pad Dimensions
Weight: 0.03g
(Recommended Value, Top View)
3.25
2.05
0.85
2.9
0.15 1.65
(0.4)
1.27
2.2
0.8
0.2
2.85
1.27
(0.35)
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K209-E1-02
1112(0912)(O)