Total Power International, Inc. Tota TPSPU16A SERIES 15W Desk Top Type I.T.E. Power Supplies Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Optional Output Connector (See page appendix) Single Output Class I Energy Star 2.0, Efficiency level V 3 year warranty Electrical Characteristics: Vin Safety Approvals Input Voltage Range 100~240VAC Operate Voltage Range 90~264VAC fin Input Frequency 47~63Hz Po Output Power Range See rating chart Vo Output Voltage Range See rating chart Io Output Current Range Iil Input Current (Low Line) Io=Full load, Vin=100VAC 0.4A Iih Input Current (High Line) Io=Full load, Vin=240VAC 0.26A Low Line Inrush Current Io=Full load, 25°C, Cool start, Vin=115VAC 15A (max.) High Line Inrush Current Io=Full load, 25°C, Cool start, Vin=230VAC 30A (max.) Efficiency Io=Full Load, Vin=230VAC 72~85% Line Regulation Io=Full Load 0.5~1% Vin=230VAC 3~7% Ir Eff REG-i REG-o Load Regulation See rating chart OVP Over Voltage Protection Over Current Protection Nil.But,Output protected to short circuit conditions Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4mS (max.) Th Hold-Up Time Io=Full Load, Vin=110VAC 8mS (min.) Ts Start Up Time Io=Full Load, Vin=100VAC 2S (max.) Nil 2002/95/EC Full Load, Vin=90VAC 1% (max.) Safety Ground Leakage Current Vin=240VAC/60Hz 0.75mA (max.) TC Temperature Coefficient All output ±0.04%/°C Pno No-Load Power Consumption No load, Vin=230VAC See rating chart Primary to secondary 4242VDC (min.) Primary to PE 2594VDC (min.) Test Voltage=500VDC 50M Vpg Ris Isolation Resistance UL/c-UL(UL 60950-1:2nd Edition) TUV/GS(EN 60950-1:2nd Edition) (min.) Note: The Ripple & Noise which is under 3.3VCD at 2% max Environmental To Operating Temperature See derating curve Ts Storage Temperature -40~85°C Ho Operating Humidity 0~95% Hr Storage Humidity 0~95% Operating Temperature at 25°C,Calculated per MIL-HDBK-217F 0.1M Hrs (min.) MTBF Pd Derate linearly from 100% load at 40°C to 50% load at 70°C Total Power International, Inc Toll Free: 877-646-0900 PS E COMPLIANT Ripple & Noise(Peak to Peak) Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage for Primary to PE RT RoHS Ilk Vps Safety Approvals: S&E OCP Vp-p Application: - Ethernet Hub - Portable Devices - Charger - Monitor - Set-top Box - AV Equipment www.total-power.com Total Power International, Inc. Tota TPSPU16A SERIES 15W Desk Top Type I.T.E. Power Supplies Output Voltage And Current Rating Chart ( Single Output ) : Output Voltage Output Current Total Regulation Max . Output Power Pno (max.) TPSPU16A-101 3 ~ 5 VDC 2.50 A max 7% 12W 0.3W TPSPU16A-102 5 ~ 5.99 VDC 2.50 ~ 2.00 A 5% 12W 0.3W TPSPU16A-103 6 ~ 8 VDC 2.00 ~ 1.50 A 5% 12W 0.3W TPSPU16A-104 8 ~ 11 VDC 1.87 ~ 1.36 A 5% 15W 0.3W TPSPU16A-105 11 ~ 13 VDC 1.36 ~ 1.15 A 5% 15W 0.3W TPSPU16A-106 13 ~ 16 VDC 1.15 ~ 0.94 A 5% 15W 0.3W TPSPU16A-107 16 ~ 21 VDC 0.94 ~ 0.72 A 5% 15W 0.3W TPSPU16A-108 21 ~ 27 VDC 0.72 ~ 0.55 A 5% 15W 0.3W TPSPU16A-109 27 ~ 33 VDC 0.55 ~ 0.45 A 5% 15W 0.3W TPSPU16A-110 33 ~ 40 VDC 0.45 ~ 0.37 A 3% 15W 0.3W TPSPU16A-111 40 ~ 48 VDC 0.37 ~ 0.31 A 3% 15W 0.3W Model Number Mechanical Specifications: Note: 1. Dimensions are shown in mm. 2. Weight: 165gs approx. 3. Optional output connector: See page Appendix. Derating Curve : 1. Operating Temperature: 0 to 70°C 2. Derate linearly from 100% load at 40°C to 50% load at 70°C 120% Output Watts (%) 100% 80% 60% 40% 20% 0% 0 10 20 30 40 50 60 70 80 Temperature (deg c) Total Power International, Inc Toll Free: 877-646-0900 www.total-power.com