View Spec Sheet

Total Power International, Inc.
Tota
TPSPU16A SERIES
15W Desk Top Type
I.T.E. Power Supplies
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Optional Output Connector (See page appendix)
Single Output
Class I
Energy Star 2.0, Efficiency level V
3 year warranty
Electrical Characteristics:
Vin
Safety Approvals Input Voltage Range
100~240VAC
Operate Voltage Range
90~264VAC
fin
Input Frequency
47~63Hz
Po
Output Power Range
See rating chart
Vo
Output Voltage Range
See rating chart
Io
Output Current Range
Iil
Input Current (Low Line)
Io=Full load, Vin=100VAC
0.4A
Iih
Input Current (High Line)
Io=Full load, Vin=240VAC
0.26A
Low Line Inrush Current
Io=Full load, 25°C, Cool start, Vin=115VAC
15A (max.)
High Line Inrush Current
Io=Full load, 25°C, Cool start, Vin=230VAC
30A (max.)
Efficiency
Io=Full Load, Vin=230VAC
72~85%
Line Regulation
Io=Full Load
0.5~1%
Vin=230VAC
3~7%
Ir
Eff
REG-i
REG-o Load Regulation
See rating chart
OVP
Over Voltage Protection
Over Current Protection
Nil.But,Output protected to short circuit conditions
Ttr
Time of Transient Response
Io=Full Load to Half Load, Vin=100VAC
4mS (max.)
Th
Hold-Up Time
Io=Full Load, Vin=110VAC
8mS (min.)
Ts
Start Up Time
Io=Full Load, Vin=100VAC
2S (max.)
Nil
2002/95/EC
Full Load, Vin=90VAC
1% (max.)
Safety Ground Leakage Current
Vin=240VAC/60Hz
0.75mA (max.)
TC
Temperature Coefficient
All output
±0.04%/°C
Pno
No-Load Power Consumption
No load, Vin=230VAC
See rating chart
Primary to secondary
4242VDC (min.)
Primary to PE
2594VDC (min.)
Test Voltage=500VDC
50M
Vpg
Ris
Isolation Resistance
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
(min.)
Note: The Ripple & Noise which is under 3.3VCD at 2% max
Environmental
To
Operating Temperature
See derating curve
Ts
Storage Temperature
-40~85°C
Ho
Operating Humidity
0~95%
Hr
Storage Humidity
0~95%
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
0.1M Hrs (min.)
MTBF
Pd
Derate linearly from 100% load at 40°C to 50% load at 70°C
Total Power International, Inc
Toll Free: 877-646-0900
PS
E
COMPLIANT
Ripple & Noise(Peak to Peak)
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to PE
RT
RoHS
Ilk
Vps
Safety Approvals:
S&E
OCP
Vp-p
Application:
- Ethernet Hub
- Portable Devices
- Charger
- Monitor
- Set-top Box
- AV Equipment
www.total-power.com
Total Power International, Inc.
Tota
TPSPU16A SERIES
15W Desk Top Type
I.T.E. Power Supplies
Output Voltage And Current Rating Chart ( Single Output ) :
Output Voltage
Output Current
Total
Regulation
Max .
Output Power
Pno (max.)
TPSPU16A-101
3 ~ 5 VDC
2.50 A max
7%
12W
0.3W
TPSPU16A-102
5 ~ 5.99 VDC
2.50 ~ 2.00 A
5%
12W
0.3W
TPSPU16A-103
6 ~ 8 VDC
2.00 ~ 1.50 A
5%
12W
0.3W
TPSPU16A-104
8 ~ 11 VDC
1.87 ~ 1.36 A
5%
15W
0.3W
TPSPU16A-105
11 ~ 13 VDC
1.36 ~ 1.15 A
5%
15W
0.3W
TPSPU16A-106
13 ~ 16 VDC
1.15 ~ 0.94 A
5%
15W
0.3W
TPSPU16A-107
16 ~ 21 VDC
0.94 ~ 0.72 A
5%
15W
0.3W
TPSPU16A-108
21 ~ 27 VDC
0.72 ~ 0.55 A
5%
15W
0.3W
TPSPU16A-109
27 ~ 33 VDC
0.55 ~ 0.45 A
5%
15W
0.3W
TPSPU16A-110
33 ~ 40 VDC
0.45 ~ 0.37 A
3%
15W
0.3W
TPSPU16A-111
40 ~ 48 VDC
0.37 ~ 0.31 A
3%
15W
0.3W
Model Number
Mechanical Specifications:
Note:
1. Dimensions are shown in mm.
2. Weight: 165gs approx.
3. Optional output connector:
See page Appendix.
Derating Curve :
1. Operating Temperature: 0 to 70°C
2. Derate linearly from 100% load at 40°C to 50%
load at 70°C
120%
Output Watts (%)
100%
80%
60%
40%
20%
0%
0
10
20
30
40
50
60
70
80
Temperature (deg c)