Spec Sheet

specifications
TM
Small form factor fiber optic modules and
connectors shall be compliant with the TIA
FOCIS-6 Fiber Jack (FJ) interface specification.
RJ-45 style module and connector shall be field
terminable in one module space with no adapter.
The fibers shall terminate in 2.5mm ferrules with
non-optical disconnect and typical insertion loss
of 0.1dB per connector.
NETWORK CONNECTIVITY GROUP
SPEC SHEET
MINI-COM ® OPTI-JACK ® Fiber Optic Module — Multimode
technical information
OPTI-JACK Fiber Optic Module
Fiber cable types: 3.0mm jacketed or 900µm buffered, works with 62.5/125µm or
50/125µm multimode
Multimode:
Ferrule type:
Ceramic (Zirconia)
Multimode:
Insertion loss:
0.1dB typical
Return loss:
Greater than 20dB
FJJGM5C**
™
OPTI-PLUG Fiber Optic Connector
FJEPGM5C**
Plug to Plug Coupler
Plug to plug coupler:
FJGCCEI
(primarily used in testing)
Termination Tooling
key features and ...benefits
Termination kit:
Consumables kit:
FJKITG
FJKITG-RFB
Small form factor connector
Double the port density in one module space at
the outlet and in the telecommunications closet
Replacement Ferrules (Multimode)
Proven 2.5mm ferrules
Uses standard termination tools and procedures
OPTI-JACK module:
OPTI-PLUG connector:
Robust design
Protects fibers from mechanical and environmental
stress
Multimode Duplex Patch Cords
Non-optical disconnect
Maintains data transmission under tensile load
RJ-45 form factor
Familiar to end-users, snaps into all MINI-COM
outlets and modular patch panels
Field terminable
module and connector
Allows flexibility to assemble special length patch
cords on site
Adapterless
Fewer components to order and inventory
Flush mount
Unused ports do not protrude from the wall; can be
used with shuttered faceplates
TIA standardization
FOCIS-6 interface approved at the TIA, required for
TIA/EIA-568-B.3
Keyed solution available
Provides network security; limits access to highly
sensitive, classified and segregated networks
applications
Fiber-to-the-desk: The OPTI-JACK fiber optic
module is the ultimate desktop fiber
connector. The 2.5mm ferrule provides
robustness required for this demanding
environment. The FJ interface module and
connector design is familiar to the end user
and is polarized to prevent mismatch of
transmit and receive cables. Because there is
no adapter, unused ports remain flush with
the wall and away from damage. Shuttered
faceplates can be used for further protection
of the unused ports. The modularity with
copper connectors allows for the complete
data-communications solution to every
workstation in one outlet.
Keyed network security: Four color-coded,
keyed configurations of the module and
connector are available to provide mechanical
and visual differentiation to prevent
unintentional insertion into adjacent ports.
Provides network security for military,
government, financial and educational
applications. Universal keyed connector
available for testing purposes.
Telecommunications closet: The high port
density of the OPTI-JACK module reduces the
space requirements for fiber terminations in
the closet. This allows the end user to use
less rack space and purchase fewer fiber
enclosures. The multiple color options allow
color coding of different networks or areas of
the building for easier troubleshooting.
V i s i t o u r w e b s i t e a t : w w w. p a n d u i t . c o m / n c g
OPTI-PLUG connector
to OPTI-PLUG connector:
OPTI-PLUG connector
to OPTI-JACK module:
OPTI-PLUG connector
to SC:
OPTI-PLUG connector
to ST:
OPTI-PLUG connector
to FC:
OPTI-PLUG connector
(Keyed W) to SC:
OPTI-PLUG connector
(Keyed W) to ST:
FJJFRL-X
FJEPFRL-X
F^D6P-6PM‡
F^D6P-6JM‡
F^D6P-3M‡
F^D6P-2M‡
F^D6P-4M‡
F^D6PW-3M‡
F^D6PW-2M‡
All key type (W, X, Y, Z) patch cords available
^Available in 62.5/125µm (6) and 50/125µm (5)
‡Available in 1, 2, 3 and 10 meters
**Substitute for
Colors:
EI = Electric Ivory
BL = Black
BU = Blue
IW = Off White
OR = Orange
WH = White
Keyed Colors: WBL = Keyed W in Black
XRD = Keyed X in Red
YOR = Keyed Y in Orange
ZYL = Keyed Z in Yellow
“X” = Bag of 10 ferrules and crimp sleeves
installer tip
A-B polarity
easily reversed
by removing
module cover.
MINI-COM ® OPTI-JACK ® Fiber Optic Module — Multimode
Standards Compliant Connector Performance
TIA
455
ISO/IEC
874-1
Description
Test Procedure and
TIA/EIA-568-B.3 Required Performance
Performance
After Test
1
--
Flex
100 cycles; -180 to 180 degrees;
max. insertion loss 0.75dB, min. return loss 20dB
<0.2dB
additional loss
2
4.5.11
Impact
8 drops from 1.8m;
max. insertion loss 0.75dB, min. return loss 20dB
<0.1dB
additional loss
4
4.5.18
High Temperature
4 days at 60°C followed by post-conditioning FOTP-6;
max. insertion loss 0.75dB, min. return loss 20dB
<0.2dB
additional loss
5
4.4.19
Humidity
4 days at 90-95% RH and 40°C;
max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.4dB
<0.1dB
additional loss
6
4.5.4
Cable Retention
11.24 lbs. at 0 degrees, 4.4 lbs. at 90 degrees;
max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.5dB
<0.2dB
additional loss
21
4.5.32
Durability
500 mate/unmate cycles;
max. insertion loss 0.75dB, min. return loss 20dB
<0.1dB
additional loss
34
4.4.7
Insertion Loss
max. insertion loss 0.75dB, min. return loss 20dB
0.1dB typical
36
4.5.5
Twist
10 cycles; 2.5 cw, 5 ccw, 2.5 cw;
max. insertion loss 0.75dB, min. return loss 20dB
<0.1dB
additional loss
107
--
Return Loss
20dB minimum return loss
>20dB
185
4.5.6
Coupling Strength
7.4 lbs. at 0 degrees;
max. insertion loss 0.75dB, min. return loss 20dB
188
4.5.17
Low Temperature
4 days at 0°C;
max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.3dB
<0.1dB
additional loss
<0.1dB
additional loss
NOTE: Above tests performed at 850 and 1300nm on 3.0mm jacketed fiber cable.
.48
[12.1]
.53
[13.4]
.25
[6.4]
.25
[6.4]
2.17
[55.0]
“A” & “B” DESIGNATION
UNDER BOOT AFTER ASSEMBLY
.48
[12.2]
.26
[6.6]
.71
[18.0]
1.96 [49.7]
.26
[6.7]
Keyed W - Black
Keyed X - Red
Keyed Y - Orange
Keyed Z - Yellow
Dimensions are in inches (Dimensions in parentheses are in millimeters)
Our products are warranted to be free from defects in material and workmanship at the time of sale but our
obligation under this warranty is limited to the replacement of any product proved to be defective within 6
months (for product) or 90 days (for tools) from the date of delivery. Tool warranty is void if Panduit tools
are modified, altered or misused in any way. Use of Panduit tooling with any product other than the specified
Panduit products for which the tool was designed, constitutes misuse. Before using, user shall determine
the suitability of the product for his intended use and user assumes all risk and liability whatsoever in
connection therewith.
NETWORK CONNECTIVITY GROUP
PANDUIT CANADA
Div. of PANDUIT CORP.
Markham, Ontario
Phone: 905-475-6922
EUROPEAN HEADQUARTERS
PANDUIT EUROPE LTD.
London, UK
Phone: 44(0) 208-601-7200
WORLD HEADQUARTERS
PANDUIT CORP.
Tinley Park, Illinois, USA
Phone: 888-506-5400, ext. 6914
708-532-1800, ext. 6914
Fax: 708-460-2897
Email: [email protected]
Internet: www.panduit.com/ncg
ASIAN HEADQUARTERS
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
Phone: (65) 379 6700
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
This warranty is made in lieu of and excludes all other warranties, expressed or implied. THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE ARE SPECIFICALLY
EXCLUDED. Neither seller nor manufacturer shall be liable for any other injury, loss or damage whether direct
or consequential, arising out of the use of, or the inability to use, the product.
The information contained in this literature is based on our experience to date and is believed to be reliable.
It is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not
guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein
are for reference purposes only. For specific dimensional requirements consult the factory. This publication is
not to be taken as a license to operate under, or a recommendation to infringe any existing patents. This
supersedes and voids all previous literature, etc.
For Pricing and Further Information —
Contact your local authorized
PANDUIT PAN-NET ™ Distributor or Sales Office
PANDUIT CORP.
Japan Branch
Phone (81) (3) 3767-7011
PANDUIT MEXICO/LATIN AMERICA
& CARIBBEAN
Phone: (52) 3 666-2501
© PANDUIT Corp. 2001
ALL RIGHTS RESERVED
PANDUIT (AUST.) PTY. LTD.
Phone: (61) 3-9794 9020
SA-NC04SP01D