Product Data Sheet Industrial Automation VersaTRAK® IPm2m® RTU Sixnet's IPm2m® industrial RTU gives you a competitive edge...real-time information anytime and anywhere allows you to make fast, cost-effective decisions. This industrial automation product is the “front-end” that brings real-time data from distributed locations to the Internet or into your central information server. Product Highlights Overview A Powerful Solution for Remote Site Management, IPm2m ® is an innovative combination of industrial RTU (Remote Terminal Unit), datalogger, real-time database client and telemetry interface in a compact installation-ready package and features rugged, flexible performance. Industrial RTU Product Highlights Internet/Intranet connectivity (Ethernet and wireless) Easy to configure datalogger Advanced control capability Advanced communications Up to 5 com ports (1 Ethernet and 4 serial) Modbus TCP/IP UDP/IP, ASCII, and RTU DNP3 SNMP PPP IEC 60870-5-101/104 Highly scalable with additional I/O modules 26 I/O channels including counters and 16 bit analog OEM packaging available Flexible open source Linux Software To learn more about our IPm2m ® Industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Features Industrial RTU Features Diagnostic LEDs Network status Serial port activity Discrete I/O status Power status PoE connected Fast Ethernet 10/100 Base Tx Auto cross-over Auto-speed detecting Flexible Communications RS232 links to modems and other devices RS485 for networking Modbus device Abundant I/O 8 DI, 4 DO, 8 AI, 2 AO Flexible high speed counters Time proportioned outputs High resolution 16 bit analog Configurable watch dog output Mounting Options Direct-panel mount DIN-rail mounting: horizontal or vertical Powerful CPU 32 bit processing 16 Meg Flash disk for programs and datalogging 32 Meg fast DRAM Open Linux OS Software Options Flexible Software Options Easy to use datalog wizard IEC61131-3 graphical programming including ladder logic, function blocks and more C and C++ support (open Linux) Optional user web pages Service & Support Long Term Support and Service Policy Easy to Service Hot swap module without disturbing wiring Remote configuration and firmware updates To learn more about our IPm2m ® Industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Specs Performance Specifications Industrial power PC (32 bit data bus) Operating system embedded Linux Dynamic memory (RAM) 32 Mbytes - 32bit, 0 wait states Program memory (Flash) 32 Mbytes Retained memory (RAM) 512K (battery-backed) Local I/O (on-board) 26 (see ordering info.) I/O Expansion (up to 256) RS485 or Ethernet Datalogging support IEC 61131 programming High Level C programming, Linux open source Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols: TCP/IP, ARP, UDP, ICNP, DHCP, Modbus/TCP, Sixnet, and more Serial Port RS485 port A screws (485+, 485-, GND) (2-wire half-duplex) RS232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR,DSR, GND) Protocols: (master and slave) Sixnet and Modbus RTU/ASCII; many others available in Linux Flow control hardware, software, RTS-party (for radios and RS485) Discrete Inputs 12 channels (sinking or sourcing) Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage and current 5.0 VDC and 1.5 mA DC Input resistance 10K Ohms Input current @ 24 VDC 3 mA Filtered ON/OFF delay 25 mS (20 Hz max. counting) Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (channels 1 - 8) see above (10 KHz on channel 1) Discrete Outputs 4 channels (10-30 VDC) Maximum output per channel 1 Amp Maximum output per module 4 Amps Max. OFF state leakage 0.05 mA Minimum load 1 mA Inrush current 5 Amps (100 mS surge) Typical ON resistance 0.3 Ohms Typical ON voltage (@1A) 0.3 VDC Analog Inputs 8 channels (4-20 mA) A/D resolution 16 bits (0.003%) Full scale accuracy +/-0.1% (@20°C) Span and offset temp. coef. +/-50 ppm per °C Input impedance 100 Ohm Current protection Self-resetting fuses DMRR (differential mode rejection) 66 dB at 50/60 Hz CMRR (common mode rejection) Not applicable since analog inputs are single ended. Analog Outputs up to 2 channels (4-20 mA) D/A resolution 16 bits (less than 1 mA) Full scale accuracy (@ 20°C) +/- 0.02% Span and offset temp. coef. +/- 50 ppm per °C typical Max. output settling time 5 mS (to .05%) Load resistance range (@ +24 VDC supply) 0-750 Ohms Short circuit protection current limiting Environmental DIN-rail or flat-panel mount Input power: 10-30 VDC Input current: 100 mA @ 24 VDC (typical) Temperature: -40 to 70°C (-40 to 85°C storage) Humidity: 5% to 95% RH (non-condensing) Flammability: UL 94V-0 materials Electrical safety: UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions: FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity: EN61326-1 (EN61000-4-2,3,4,6) Surge withstand: IEEE-472 (ANSI C37.90) Vibration: IEC68-2-6 Hazardous locations: (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards To learn more about our IPm2m ® Industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Add I/O Part Number (Module with wiring base) Part Number (Including PoE) DI DO AI AO Description E2-MIX24880-D EB-MIX24880-D 24 8 8 0 Combination I/O module with 1 isolated input counter * E2-MIX24882-D EB-MIX24882-D 24 8 8 2 Combination I/O module with 2 analog outputs ** E2-32DI24-D EB-32DI24-D 32 - - - 32 inputs (10-30 VDC) E2-16DI24-D EB-16DI24-D 16 - - - 16 individually isolated channels, 10-30 VDC/VAC with counters 16 - - - 16 individually isolated inputs,120 VAC nominal E2-16DIAC-D - E2-32DO24-D EB-32DO24-D - 32 - - High density discrete outputs E2-16DO24-D EB-16DO24-D - 16 - - Individually isolated 1 Amp outputs with self-resetting fuses E2-32AI20M-D EB-32AI20M-D - - 32 - High density 16 bit 4-20mA inputs with self-resetting fuses E2-32AI10V-D EB-32AI10V-D - - 32 - Voltage inputs E2-16AI20M-D EB-16AI20M-D - - 16 - 16 channels 4-20mA inputs with self-resetting fuses E2-8AO20M-D EB-8AO20M-D - - - 8 4-20mA analog outputs E2-16AI-8AO-D EB-16AI-8AO-D - - 16 8 16 4-20mA inputs plus 8 4-20mA outputs E2-16ISOTC-D*** EB-16ISOTC-D*** - - 16TC - Instrumentation thermocouples E2-8ISOTC-D*** EB-8ISOTC-D*** - - 8TC - Instrumentation thermocouples E2-16ISO20M-D *** EB-16ISO20M-D *** - - 16 - Isolated 4-20mA inputs E2-10RTD-D EB-10RTD-D - - 10 RTD - RTD (100 Ohm platinum), -200 to 850°C. Note: * 24 maximum DI’s are listed, 8 of which can be configured as either DI or DO. The discrete outputs are protected by self-resetting fuses. ** EB part number prefix (above) is for modules that include the optional PoE feature. Standard product part numbers begin with E2. *** Please check factory for availability To learn more about our IPm2m ® Industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Usage How Much Datalogged Information Can be Stored? Each Sixlog file is allocated a fixed amount of memory. Each record typically contains a time stamp (4 bytes), analog values (2 bytes each), and discrete values (8 per byte). The size of the record is automatically computed and displayed for you by the Sixlog software. The overall storage time (until the oldest data in a full file is overwritten by new data) is computed as: Longest storage = (file size) x (capture interval) / (bytes per record) Example: 16 analog values plus a time stamp ( 32 + 4 = 36 bytes) are logged every 5 minutes into a 400K file. Oldest data = 400,000 (approx) x 5 minutes / 36 bytes/record = 55,555 Minutes (38 days) By default, the VersaTRAK® IPm2m has more than 400K for datalogging. Adding I/O modules to a VersaTRAK IPm2m Industrial RTU Any combination of EtherTRAK-2 , EtherTRAK and RemoteTRAK I/O modules can be connected to a VersaTRAK® IPm2m A single VersaTRAK® IPm2m supports up to 256 EtherTRAK and/or RemoteTRAK I/O. Why VersaTRAK® IPm2m Instead of other Sixnet Controllers? VersaTRAK® IPm2m offers 32 Megabytes of fast dynamic memory and 64 Megabytes of Flash disk. VersaTRAK® IPm2m includes bundled software applications (AGA gas calculations and DNP-3 time stamped communications) for the utility industries make your job easier. VersaTRAK® IPm2m offers built-in I/O, Ethernet and up to four serial ports. The embedded LINUX operating system in the VersaTRAK® IPm2m offers greater programming flexibility and performance than the legacy VersaTRAK / Mini-VersaTRAK RTUs. To learn more about our IPm2m ®Industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Order Guide Part Number DI DO AI AO RS 232 RS Eth 485 Memory IPm2m RTU and Datalogger VT-IPM2M-113-D 12 4 8 0 1 1 1 32MB Flash & DRAM VT-IPM2M-213-D 12 4 8 2 1 1 1 32MB Flash & DRAM VT-MIPM-135-D 12 8 6 0 2 1 1 512KB NVRAM 64MB Flash 32MB DRAM VT-MIPM-245-D 12 4 8 2 2 2 1 512KB NVRAM 64MB Flash 32MB DRAM 8 4 2 0 2 1 1 Mini IPms VT-uIPm RTUs VT-UIPM-431-H Legacy RTUs: Legacy RTU Part Numbers 16MB Flash & DRAM RS RS Eth 232 485 DI DO AI AO Memory VT-MIPM-131-D 12 8 6 0 2 1 1 512KB NVRAM 16MB Flash & DRAM VT-MIPM-241-D 12 4 8 2 2 2 1 512KB NVRAM 16MB Flash & DRAM 8 4 0 0 3 1 1 Mini IPms VT-uIPm RTUs VT-UIPM-441-H Replacement Guide: Legacy Product 16MB Flash & DRAM Replacement RTUs ST-IPm-1350 ST-IPm-6350 ST-IPm-2350 ST-IPm-6350 VT-IPm-2410 ST-IPm-6350 or VT-IPm-1410 VT-MIPm-131-D VT-MIPm-135-D VT-MIPm-241-D VT-MIPm-245D To learn more about our IPm2m ® Industrial RTU, simply contact [email protected] or call +1 518 877 5173