D ATA S H E E T EtherTRAK®-2 Ethernet I/O Module Industrial Automation Sixnet’s EtherTRAK®-2 Ethernet I/O modules provide a simple and secure way to reliably monitor remote sites located in harsh environments. Offering the lowest cost per I/O point and rugged environmental ratings, EtherTRAK-2 modules are ideal for both control rooms and extreme locations across industries that include oil & gas, power & energy, transportation, mining, maritime and water/ wastewater. Our compact DIN-rail modules support open-standard protocols to provide flexible communication options for existing or newly installed Ethernet networks. By seamlessly replacing external devices such as switches, data concentrators and protocol converters, EtherTRAK-2 modules transcend simple I/O capabilities to cost-effectively streamline systems and improve reliability. PRODUCT HIGHLIGHTS mix of I/O channels support • allFlexible instrumentation needs • Real-Time Ring™ for fast redundancy independent Ethernet ports • Dual enable flexible networking security proactively blocks • Built-in unwanted access health diagnostics and • Extensive reporting reduce downtime Modbus protocols provide • Standard universal compatibility design supports extreme • Rugged temperatures and hazardous Control Center IPm Controller Ring Switch locations IPm Controller Service Room Ring Switch Real-Time Ring APPLICATIONS • Oil & Gas & Energy • Power - Transmission EtherTRAK-2 I/O Modules EtherTRAK-2 I/O Modules - Distribution •Transportation •Mining •Maritime • Water/Wastewater CONNECT. MONITOR. CONTROL. Pump Room Engine Room Off-Shore Oil Rig EtherTRAK-2 Ethernet I/O Module Industrial Automation INDUSTRIAL AUTOMATION Sixnet’s rugged RTUs and I/O provide a simple yet powerful means to reliably monitor and control remote sites around the clock in the harshest environments. Our compact automation systems can start small and grow as needs increase without requiring hardware replacement. Virtually unlimited scalability means organizations have fewer restrictions on the number of remote sites or devices that are supported. “Best of both worlds” programming combines Windows ease of use with the future-proof security of an embedded Linux OS. FEATURES & BENEFITS High-Performance, Flexible I/O Configuration Maintenance & Monitoring • Provides high-speed functionality • Lowers overall cost per I/O point –Flexible mix of up to 34 I/O supports DI, DO, AI, AO, temperature (RTD and thermocouples) –High resolution 16-bit analog or high-speed 10-bit analog –Fast I/O polling of up to 1mS –Advanced counter functions with 32-bit reporting –Time proportioned outputs simplify high-speed pulse rate functions • Delivers cross-platform configuration • Offers easy-to-use software tools – Configuration and monitoring via standard web browser – On-board storage for project documentation – Project-based software tools – User-based history tracks changes – Per-channel calibration – Configuration archiving – Module hot-swap capabilities Rugged, Compact Design • Supports harsh environments • Delivers proven reliability – Industrial -40 to 75°C operating range – UL/CSA (CUL), FCC and CE rated – Hazardous locations rated for Class I, Div 2 (Zone 2) areas – Vibration resistant IEC68-2-6 – Self-resetting fuses protect I/O Built-In Security • Prevents unwanted intrusion • Guards against unauthorized users – User-assigned permissions – Firewall protection Flexible, Redundant Networking • Simplifies connectivity by replacing Ethernet switches • Ensures reliability without additional cost –Real-Time Ring switch mode for fast redundancy –Switch elimination mode enables daisy-chaining –Dual independent Ethernet ports –Ethernet, RS-485 and USB connections –Optional Power over Ethernet (PoE) –Embedded data concentrator Watchdog Monitoring & Reporting • Provides health reports of various module functions • Reduces maintenance downtime – CPU health – Dual-power status – PoE status – Port link status • Fail-safe outputs – Communication activity – Heartbeat watchdog monitor NETWORKING OPTIONS Break in Cable Active Data Path Real-Time Ring Switch Mode Create redundant Ethernet reliability without additional cost Backup Data Path Switch Elimination Mode Daisy-chain modules without external switches to save money and simplify connectivity LAN A LAN B Two Networks Mode CONNECT. MONITOR. CONTROL. Each Ethernet port has a unique MAC and IP address for connection to two independent physical networks SPECIFICATIONS General I/O Performance Discrete Input Channels • Power supply voltage: 10-30 VDC • Input current requirement: 75 mA @ 24 VDC typical with no loads • PoE power (EB modules only): 10 watts at 60°C for user loads • De-rate: up to 5 watts at 75°C • I/O: 512 discrete inputs and outputs plus 256 analog input and output registers • Unique station addresses: 16,000+ (Sixnet or 247 Modbus) • • • • Ethernet Performance • Ethernet ports: 10/100BaseTx (auto-detecting) • Connection: RJ45 (auto-crossover) • Isolation: 1500 volts RMS 1 minute (60 Hz.) • Message response time: <1 mS per message • Diagnostic LEDs: solid indicates link, blinking indicates activity • Protocol support: TCP/IP, ARP, UDP, ICMP, DHCP, HTTP, Modbus UDP/TCP slave mode, Modbus UDP master mode, Sixnet UDR UDP/ TCP slave mode, Sixnet UDR UDP master mode • Real-Time Ring: 5ms per hop recovery time • Independent networks: 1 or 2 with unique MAC and IP addres Serial Ports • RS-485 port: screw terminals (485+, 485-, GND; 2-wire halfduplex, not isolated) • RS-485 networking: up to 32 (full load) stations • RS-485 distance: up to 0.5 miles (baud-rate dependent) • Baud rates: from 300 to 57,600 baud • Protocols: TCP/IP, ARP, UDP, ICMP, DHCP, HTTP, Modbus UDP/ TCP slave mode, Modbus UDP master mode, Sixnet UDR UDP/TCP slave mode, Sixnet UDR UDP master mode • Protocols: master and slave; Sixnet and Modbus RTU/ASCII • Diagnostic LEDs: transmit (TD) and receive (RD) Analog Output Channels • • • • • • • Analog output range: 4-20 mA D/A resolution: 16 bits (less than 1 uA) Full scale accuracy: +/-0.02% (at 20°C) Span and offset temperature: +/- 50 ppm per °C Load resistance (@ 24 V): 0-750 Ohms Current: limiting short circuit protection Refer to user manual for additional specifications Analog Input Channels • • • • • • • • • • • • Input range: 4-20mA, 0-10VDC, RTD, thermocouple and 250mV A/D resolution: 16 bits (0.003%); 10 bits (1mS fast option) Input impedance (resistance): 100 ohms or 200 Kohms Fuses: self-resetting short circuit protection (4-20 mA inputs) DMRR (differential mode): 66 db at 50/60 Hz Update time: from 880 mS to 1 mS (depending configuration) Temperature accuracy: typical uncalibrated +/-0.5°C RTD type: 100 Ohm platinum RTD alpha: 0.00385 or 0.00392 RTD connections: 2 or 3-wire RTD input range: -200 to 850°C Refer to user manual for additional specifications • • • • Voltage range: 10–30 VDC or 60–140 VAC Input isolation: 150 volts (16 channel modules only) Input resistance: 10 Kohms Slow response (software configurable): 25 mS (20 Hz. maximum counting rate) Fastest response (software configurable): 1 mS (400 Hz. maximum counting rate) Special fast counting rate: up to 50 KHz on channels 1 and 2 Count up: pulse timing and pulse rate 16 or 32-bit reporting Refer to user manual for additional specifications Discrete Output Channels • • • • • • Output voltage range: 10-30 VDC or 10-30VDC/AC Maximum output power: up to 1A per channel Short circuit protection: self-reset fuses (trip above 1.5 Amp) Input isolation: 150 volts (16 channel modules only) All channels scan rate: 1 mS Refer to user manual for additional specifications Web Interface • Secure web access with password protection for multiple users • 1 simultaneous user • 750K memory for user pages (more with special order) Environmental • Operating temperature: -40 to 75°C (-40 to 85°C storage) • Humidity: 5 to 95% RH (non-condensing; optional conformal coating) • Flammability: UL 94V-0 materials • Vibration: IEC68-2-6 Standards Compliance • Electrical safety : UL 508, CSA C22.2/14; EN61010-1 (IEC1010); CE • EMI emissions: FCC part 15, ICES-003, Class A; EN55022; EN61326-1; CE • EMC immunity : EN61326-1 (EN61000-4-2,3,4,6); CE • Hazardous locations: Class 1, Div 2, Groups A, B, C, D; UL 1604; CSA C22.2/213; Cenelec EN50021 Zone 2 • Marine and offshore: tested and/or verified to meet various standards such as DNV No. 2.4, Lloyds and ABS Physical • Mounting: DIN rail (EN50022), direct to panel or flat panel • Packaging: impact resistant Lexan® polycarbonate • Dimensions (module and base): 5.5”L x 3.5”W x 5.1”H (14cm x 8.9cm x 13cm) Warranty • 2 years on design and manufacturing defects All specifications are subject to change. Contact Sixnet to learn more. EtherTRAK-2 Ethernet I/O Module Industrial Automation ORDER GUIDE PART NUMBER DI DO AI E2 or EB-MIX24880-D 24 8 8 AO DESCRIPTION E2 or EB-MIX24882-D 24 8 8 E2 or EB-32DI24-D 32 32 discrete inputs (10-30 VDC) including 16 multifunction counters E2 or EB-16DI24-D 16 16 individually isolated discrete inputs (10-30 VDC) with counters E2 or EB-16DIAC-D 16 16 individually isolated discrete inputs (120 VAC nominal; 10-30 32 channel combination I/O with 1 isolated input counter 2 34 channel combination I/O with 2 analog outputs VDC) with counters E2 or EB-32DO24-D 32 32 discrete outputs (10-30 VDC) 0.5 Amp each, 8 Amps total E2 or EB-16DO24-D 16 16 individually isolated discrete ouputs (10-30VDC) 1 Amp outputs, 16 Amps total E2 or EB-16DORLY 16 16 individually isolated discrete outputs (10-30VDC/VAC relay) 1 Amp outputs, 16 Amps total E2 or EB-32AI20M-D 32 32 analog inputs (4-20 mA) with 16-bit accuracy E2 or EB-32AI10V-D 32 32 analog inputs (0-10VDC) E2 or EB-16AI20M-D 16 16 analog inputs (4-20 mA) E2 or EB-8AO20M-D E2 or EB-16AI-8AO-D 16 8 8 analog outputs (4-20 mA) 8 24 channel combination, 16 analog inputs (4-20 mA) and 8 analog outputs (4-20 mA) E2 or EB-16ISOTC-D 16TC 16 individually isolated analog inputs (thermocouple and +/- 250 mV) with J, K, E, R, T, C, N, S E2 or EB-8ISOTC-D 8TC 8 individually isolated analog inputs (thermocouple and +/- 250 mV) with J, K, E, R, T, C, N, S E2 or EB-16ISO20M-D 16 E2 or EB-10RTD-D 10RTD About Red Lion As the global experts in communication, monitoring and control for industrial automation, Red Lion has been delivering innovative solutions to customers for forty years. Our award-winning technology enables companies worldwide to gain real-time data visibility that drives productivity. Product brands include Red Lion, Sixnet and N-Tron. With headquarters in York, Pennsylvania, the company has offices across the Americas, Asia-Pacific and Europe. Red Lion is a Spectris company. For more information, visit www.redlion.net/sixnet, call +1 (518) 877-5173 or email [email protected] 16 individually isolated analgo inputs (4-20 mA) 10 analog inputs (100 Ohm platinum RTD), rang is -200 to 850°C MECHANICAL DRAWING www.redlion.net/sixnet +1 (518) 877-5173 | [email protected] CONNECT. MONITOR. CONTROL. © 2011 Sixnet. All Rights Reserved. OCT2012