VIEW

331 Ushers Road, P.O. Box 767, Clifton Park, NY 12065 USA
+1 (518) 877-5173, Fax +1 (518) 877-8346
email: [email protected] www.sixnetio.com
RemoteTRAK® RTU
Combination I/O module with a RS232 / RS485 Interface
Select a RM-RTU-8440 when . . .
. . . you need I/O in any of the following situations
„
„
„
„
„
Low power RTU for small sites
I/O with a RS232 connection
Modbus RS485 combination I/O
Expansion for EtherTRAK I/O
Supports radio packeting and phone link
Performance Specifications
Discrete inputs
Voltage range
Guaranteed ON voltage
Maximum voltage
Guaranteed OFF voltage & current
Input resistance
Input current @ 24 VDC
Filtered ON/OFF delay
Fast ON/OFF delay
Counters functions (all 8 inputs)
Count Rate
Discrete Outputs
Voltage range
Maximum output per channel
Maximum output per module
Max. OFF state leakage
Minimum load
Inrush current (100 mS surge)
Typical ON resistance
Typical ON voltage (@1A)
Analog Inputs
Standard range
A/D resolution
Full scale accuracy
Span and offset temp. coefficient
Input impedance
Current protection
DMRR (differential mode rejection)
8 channels
10-30 VDC
9 VDC
30 VDC
5.0 VDC & 1.5 mA DC
10K Ohms
3 mA
25 mS (20 Hz max. counting)
4 mS (100 Hz max. counting)
Pulse accumulation (count up)
Pulse rate (pulses per sec. or min.)
Running time (in sec. or minutes)
100 Hz. (or 20 Hz. when filtered)
10 KHz on channels 1 and 2
4 channels
10-30 VDC
1 Amp
8 Amps
0.05 mA
1 mA
5 Amps
0.2 Ohms
0.2 VDC
4 channels
4-20 mA
16 bits (0.003%)
+/-0.1% (@20°C)
+/-50 ppm per degree C
100 Ohm
Self-resetting fuses
66 dB at 50/60 Hz
Ordering Information
RM-RTU-8440-F
RM-RTU-8440-M
RM-RTU-8440-FB
VT-MODEM-1WW
Module and wiring base pair
Replacement module only
Replacement base only
Industrial modem
All SIXNET I/O modules have these great features:
„
„
„
„
DIN rail or direct panel mounting
Rugged Lexan™ packaging
Hot swappable modules (auto-reconfigure)
Certified to perform:
Serial Communications
Protocols supported
RS485
RS232
Supported baud rates
Factory default
Environmental
Input voltage
Input power
Operating temp. range
Storage temperature range
Humidity (non-condensing)
Vibration
Electrical safety
EMI emissions
EMC immunity
Surge withstand
Hazardous locations
(Class 1, Div 2 and Zone 2)
Marine/offshore locations
RS485 or RS232 (selectable)
Modbus ASCII & RTU, SIXNET
2 wire with optional line
termination
TD, RD, and RTS (key a modem
to transmit)
2400, 9600, 19200, 38400, 57600
9600 baud, no parity, 8 data bits,
SIXNET protocol
DIN rail or panel mounting
10-30 VDC
500 mW typical
-40 to +70°C
-40 to +85°C
5 to 95% RH
IEC68-2-6
UL508, CSA C22.2/14; EN61010
FCC part 15, ICES-003, EN55022
EN50082-1, EN61326-1
IEEE-472
UL1604, CSA C22.2/213,
EN50021, EEx nA II T4 X
Det Norske Veritas (DNV)
No. 2.4 (Class A & B)
Specifications are subject to change. Consult factory for latest information.
SIXNET n Box 767 n Clifton Park, NY 12065 USA n +1 (518) 877-5173 n Fax +1 (518) 877-8346 n [email protected]
331 Ushers Road, P.O. Box 767, Clifton Park, NY 12065 USA
+1 (518) 877-5173, Fax +1 (518) 877-8346
email: [email protected] www.sixnetio.com
RM-RTU-8440-F Power, Com and I/O Wiring
10-30 VDC
(User Supplied)
RS485 Port
RS232
Port
GND
T1 T2
19 20 21 22 23
24 25
Equivalent DC Input Circuits
GND(25)
+ DI Return Jumper:
DC+(24)
Jumper
5.1Kohms
Sourcing
Input
Switch
-
RS232
Com Jumper:
Select RS232 or RS485
RS485
Select DC- for sourcing (default)
or DC+ for sinking
Discrete Inputs
RS232
Port
(RJ45)
Pinout
--------4 GND
5 RXD in
6 TXD out
8 RTS out
Analog Ins
Discrete Outs
DIN
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
GND(25)
1
2
Ref
5.1Kohms
4
5
6
7
8
1
(sourcing or sinking DI)
DC+(24)
Jumper
3
Sinking
Input
Switch
DIN
Ref
DC+ for
DI Sourcing
or
DC- for
DI Sinking
(must set
jumper
in base)
2
3
4
1
(sourcing DO)
2
3
4
NC
(Loop powered AI shown)
DO Return (DC-)
Analog GND (DC-)
Analog Power (DC+)
10-30 VDC
(User Supplied)
Equivalent Analog
(4-20 mA) Input Circuits
Equivalent DC Output Circuit
(sourcing only)
AIN
DC+(24)
Solid State
Switch
DOUT Load
100
ohms
GND(18)
GND(25)
RM-RTU-8440-F Mechanical Dimensions
4.25"
0.28"
(10.80 cm)
(0.71 cm)
0.28"
3.23"
(8.20 cm)
2.95"
(7.49 cm)
Dia. 0.17"
(0.43 cm) (clear
for #8 screw)
SIDE VIEW
FRONT VIEW
4.47"
4.75"
(12.07 cm)
(11.35 cm)
DIN
EN
50022
1.80"
4.13"
(4.57 cm)
(10.48 cm)
SIXNET n Box 767 n Clifton Park, NY 12065 USA n +1 (518) 877-5173 n Fax +1 (518) 877-8346 n [email protected]
331 Ushers Road, P.O. Box 767, Clifton Park, NY 12065 USA
+1 (518) 877-5173, Fax +1 (518) 877-8346
email: [email protected] www.sixnetio.com
Applications Suggestions:
Poll this low power
RTU with an
industrial modem
(such as SIXNET’s
VT-MODEM) or
radio using
SIXNET or
Modbus protocol.
Expand the
number of channels
on an EtherTRAK
(Ethernet) node
with this
combination
I/O module.
This I/O module can be polled on a
RS485 party line along with other
RemoteTRAK I/O modules and
RS485 Modbus devices.
Revised: 5-Aug-04
SIXNET n Box 767 n Clifton Park, NY 12065 USA n +1 (518) 877-5173 n Fax +1 (518) 877-8346 n [email protected]