Product Data Sheet Industrial Automation RemoteTRAK® I/O Modules Sixnet's RemoteTRAK I/O module with an RS-485 communication port comes with a variety of I/O populations. RemoteTRAK I/O modules are no longer recommended for new installations. The suggested replacement for this product line is theEtherTRAK-2 I/O module. Please refer to the replacement guide located in the "Selection Guide" tab below. Product Highlights Overview I/O Module Product Highlights Twisted pair wiring (standard 2-wire RS485) Spread I/O over extended distances (up to 2 miles) Expand Modbus I/O installations Expand Sixnet EtherTRAK I/O, Controller, RTU and I/O Concentrator stations Supports Modbus, ASCII and RTU "Process Quality" I/O True hot swap of modules in live systems DIN-rail or direct-panel mounting Rugged Lexan packaging UL, CSA, CE, DNV and Zone 2 rated -30 to 70°C operating range Easy-to-use configuration software To learn more about our RemoteTRAK I/O Module, simply contact [email protected] or call +1 518 877 5173. Features General Convenient and economical “block” I/O Install I/O right where you need it True hot swap of modules in live systems Supported by excellent Windows tools Pre-integrated remote I/O for Sixnet systems Connects easily to any Modbus host Isolated communications ensures reliability Packed with all the features you need most To learn more about our RemoteTRAK I/O Module, simply contact [email protected] or call +1 518 877 5173. Specs General Characteristics Protocols supported - Modbus, ASCII/RTU and Sixnet Universal Wiring Configuration - RS485 two-wire party-line RS485 isolation - 1200 Volts RMS 1 minute (module to module) Supported baud rates - 2400, 9600, 19200, 38400, 57600 baud Factory configuration - 9600 baud, no parity, 8 data bits, Sixnet protocol Cable recommendation - Shielded, twisted pair with drain wire desirable. Data rated cable is recommended for greater distances. RS485 Limitations Cable length up to 1 km - 24 AWG and 57600 baud Cable length up to 2 km - 20 AWG and 38400 baud Cable length up to 3.5 km - 18 AWG and 19200 baud # Modules on RS485 network - 32 maximum # Addressable modules - 128 with a RM-232-485-4U Environmental Operating temperature range -30 to 70° C Storage temperature range -40 to 85° C Humidity (non-condensing) 5 to 95% Flammability (module plastic) UL 94V-0 materials UL 508 (electrical safety) EN 61010-1 or EN 60950 (Electrical safety) Vibration IEC68-2-6 EN 60079-15 Group II, Category 3 locations (ATEX) Hazardous locations UL 1604, CSA C22.2/213-M1987, (Class I, Div 2, Groups A, B, C, D), EN50021 (zone 2) Marine/offshore as rated by Det Norske Veritas (DNV) No. 2.4 (Class A and B) EN 61000-6-2 (Immunity for industrial environments) EN 61000-6-4 (Emissions for industrial environments) Model Specs RM-8DI2-U/F Discrete Inputs: 8 input channels Nominal input voltage 12/24 VDC/VAC Guaranteed ON voltage 9 VDC/VAC Maximum input voltage 30 VDC/VAC Guaranteed OFF current 1.5 mA DC Guaranteed OFF voltage 5.0 VDC Input resistance 2.4K Ohms Nominal input current @ 24VDC 10 mA Filtered ON/OFF delay 25 mS (10 Hz counting) Max. count frequency (fast mode) 100 Hz (2 KHz on channel 1) Channel to channel isolation 500 Volts (w/-U base) Isolation from internal circuitry 1200 Volts RM-16DI2-H RM-16DI2-H Discrete inputs: 16 input channels Nominal input voltage 12/24 VDC Guaranteed ON voltage 9 VDC Maximum input voltage 30 VDC Guaranteed OFF current 1.5 mA DC Guaranteed OFF voltage 5.0 VDC Input resistance 3.7K Ohms Input current @ 12 VDC 3.5 mA Input current @ 24 VDC 7 mA Filtered Mode ON/OFF delay 50 mS RM-8DO2-F Discrete Outputs: 8 output channels Output range 10-30 VDC Max. output current per channel 3 Amps (derate linearly to 2A from 50 to 70°C) Max. output current (entire module) 10 Amps Max. OFF state leakage current 0.05 mA Min. load current per channel 0.1 mA Inrush current (100 mS surge) 10 Amps Maximum inductive load 0.2 H (3 Amp load at 24 VDC) Typical ON resistance 0.1 Ohms Typical ON voltage drop (@ 1 Amp) 0.1 VDC Short circuit protection At full rated load Thermal shutdown protection 150° C RM-16DO2-H Discrete Outputs: 16 output channels Output range 10-30 VDC Max. output current per channel 1 Amp Max. output current (entire module) 10 Amps Max. OFF state leakage current 0.05 mA Min. load current per channel 0.1 mA Inrush current (100 mS surge) 5 Amps Typical ON resistance 0.3 Ohms Typical ON voltage drop (@ 1 Amp) 0.3 VDC RM-8AI2-F Analog inputs: 8 input channels Input range 4-20 mA A/D resolution 16 bits (0.003%) Full scale accuracy (@ 20° C) +/- 0.10% Span and offset temp. coefficient +/- 50 ppm per degree C Input impedance 100 Ohms DMRR (differential rejection at 50/60 Hz) 66 dB Input current protection Replaceable shunts Max. scan rate (8 channels) 500 mS Max. scan rate (16 channels) 1000 mS RM-16AI2-H Analog inputs: 16 input channels Same as RM-8AI2-F RM-8INS-U Analog inputs: 8 input channels Lowest voltage range +/- 0.062 Volts Maximum voltage range +/- 10 Volts Auto-polarity current range 4-20 mA Thermocouple types (see notes) J,K,E,R,T,B,C,N,S A/D resolution 16 bits Full scale accuracy (@20°C) +/- 0.02% Input span and offset adjustability +/- 25% Span and offset temp. coefficient +/- 30 ppm per °C typ. mV and voltage input impedance 200K Ohms CMRR (at 50/60 Hz) 140 db DMRR (at 50/60 Hz) 66 db Common mode input voltage: Between two input terminals +/- 25 VDC Between inputs and ground 1200 Volts No damage input voltage +/- 50 VDC Fastest scan rate (all 8 channels) 100 mS RM-4AO2-F Analog Outputs: 4 output channels Output range 4-20 mA D/A resolution 13 bits (0.03%) Full scale accuracy (@ 20° C) +/- 0.05% Span and offset temp. coefficient +/- 50 ppm per degree C Max. output setting time (to 0.05%) 5 mS Required user supplied loop voltage 10-30 VDC Load resistance range (@ +24V supply) 0-750 Ohms Short circuit protection Current limiting RM-8AO2-F Analog Outputs: 8 output channels Same as RM-4AO2-F RM-4DI2-4AI2-U Discrete inputs and Analog inputs: 4 Discrete input channels Input range 12/24VDC Discrete input characteristics same as RM-8DI2 4 Analog input channels Analog input characteristics same as RM-8AI2 RM-4DI2-4DO2-U Discrete inputs and outputs: 4 Discrete input channels Input range 12/24VDC Discrete input characteristics same as RM-8DI2 4 Discrete output channels Discrete output characteristics same as RM-16DO2 RM-RTU-8440-F Combination I/O module: Discrete Inputs: 8 Input channels Voltage range 10-30 VDC Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage & current 5.0 VDC & 1.5 mA DC Input resistance 10K Ohms Input current @ 24 VDC 3 mA Filtered ON/OFF delay 25 mS (20 Hz max. counting) Fast ON/OFF delay 4 mS (100 Hz max. counting) Counters functions (all 8 inputs) Pulse accumulation (count up) Pulse rate (pulses per sec. or min.) Running time (in sec. or minutes) Count Rate 100 Hz. (or 20 Hz. when filtered) 10 KHz on channels 1 and 2 Discrete Outputs: 4 output channels Voltage range 10-30 VDC Maximum output per channel 1 Amp Maximum output per module 8 Amps Max. OFF state leakage 0.05 mA Minimum load 1 mA Inrush current (100 mS surge) 5 Amps Typical ON resistance 0.2 Ohms Typical ON voltage (@1A) 0.2 VDC Analog Inputs: 4 input channels Standard range 4-20 mA A/D resolution 16 bits (0.003%) Full scale accuracy +/-0.1% (@20°C) Span and offset temp. coefficient +/-50 ppm per degree C Input impedance 100 Ohm Current protection Self-resetting fuses DMRR (differential mode rejection) 66 dB at 50/60 Hz To learn more about our RemoteTRAK I/O Module, simply contact [email protected] or call +1 518 877 5173. Selection Guide Part Number Description DI AI DO AO RM-8DI2-F 10-30VDC discrete inputs, field wiring 8 - - - RM-8DI2-U 10-30VDC discrete inputs, universal wiring 8 - - - RM-16DI2-H 10-30VDC discrete inputs, high density 16 - - - RM-8DO2-F 10-30VDC discrete outputs, field wiring - - 8 - RM-16DO2-H 0-30VDC discrete outputs, high density - - 16 - RM-8AI2-F 4-20mA analog inputs, 16-bit resolution - 8 - - RM-16AI2-H 4-20mA analog inputs, 16-bit resolution, high density - 16 - - RM-8INS-U instrumentation inputs, (thermocouples, Volt, 4-20mA, etc.) - 8 - - RM-4AO2-F 4-20mA analog outputs, 13-bit resolution - - - 4 RM-8AO2-F 4-20mA analog outputs, 13-bit resolution - - - 8 RM-4DI2-4AI2-U 10-30VDC discrete inputs and 4-20mA analog inputs 4 4 - - RM-4DI2-4DO2-U 10-30VDC discrete inputs and discrete outputs 4 - 4 - RM-RTU-8440-F Low cost RTU, mix of discrete ins and outs, & analog ins 8 4 4 - RM-232-485-4U Converter for RS232 to RS485 (2 wire), connect up to 128 modules RM-232-SETUP Field setup module (includes ST-CABLE-PF). Required for initial configuration. Replacement Guide for I/O Modules Legacy Product Replacement RemoteTRAK DI DO AI AO EtherTRAK-2 DI DO AI AO RM-8DI2-F 8 0 0 0 E2-16DI24 16 0 0 0 RM-8DI2-U 8 0 0 0 E2-16DI24 16 0 0 0 RM-16DI2-H 16 0 0 0 E2-32DI24 32 0 0 0 RM-8DO2-F 0 8 0 0 E2-16DO24 0 16 0 0 RM-16DO2-H 0 16 0 0 E2-32DO24 0 32 0 0 RM-8AI2-F 0 0 8 0 E2-32AI20M 0 0 32 0 RM-16AI2-H 0 0 16 0 E2-32AI20M 0 0 32 0 RM-8INS-U 0 0 8 0 E2-16ISOTC/ISO20M 0 0 16 0 RM-4AO2-F 0 0 0 4 E2-8AO20M 0 0 0 8 RM-8AO2-F 0 0 0 8 E2-8AO20M 0 0 0 8 RM-4DI2-4AI2-U 4 0 4 0 E2-MIX24880 24 8 8 0 RM-4DI2-4DO2-U 4 4 0 0 E2-MIX24880 24 8 8 0 RM-RTU-8440-F 8 4 4 0 E2-MIX24880 24 8 8 0 To learn more about our RemoteTRAK I/O Module, simply contact [email protected] or call +1 518 877 5173. Software Industrial Automation Devices Software & Firmware Downloads New Firmware Releases Legacy Firmware Revision History Firmware Loader USB Driver ISaGRAF Sixnet I/O Tool Kit To learn more about our industrial RTU's, simply contact [email protected] or call +1 (518) 877-5173.