Product Data Sheet Industrial Automation VersaTRAK® uIPm® RTU Sixnet's Micro-VersaTRAK µIPm™ (Micro-IPm) industrial RTU is the ideal plant-floor interface for data-oriented applications such as RFID and bar code tag systems. The Micro-IPm is a Linux open-source platform, an expandable, programmable datalogger and includes communication ports and I/O. A complete package. Product Highlights Overview This Linux open-source platform is adapted to database applications. Sixnet's optional Sixlog software records transactions, events and trend data. It includes abundant communication ports and I/O to complete the application. Industrial RTU Product Highlights Ideal for ID tag applications, serial ports link to code readers Datalogging, time-stamp trending, alarm logging and transaction recording Stand-alone control of remote sites, IEC 61131 ISaGRAF as well as C++ programming via open source Linux Limitless multi-user connectivity telephone, Internet and wireless telemetry, 10/100 Ethernet plus up to 4 com ports Embedded Linux open source software makes adding applications and I/O drivers easy Where to use the Micro IPm RFID and bar code tag applications Real-time inventory management Remote monitoring and control HVAC and energy management Environmental monitoring Low-cost OEM applications To learn more about our µIPm industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Features Compact & Modular Packaging Built-in I/O - 8 DI, 4 DO & 2 AI (optional) Expandable up to 256 I/O per type with EtherTRAK and RemoteTRAK I/O modules DIN-rail or direct-panel mounted Advanced Software Features Flexible open-source LINUX software Ideal for database applications Powerful C/C++ programming ISaGRAF IEC 61131 programming Datalogging and alarming Peer to peer I/O transfer capability IPm Add-on applications AGA, DNP3, SNMP, PPP and more Other automation and control features Advanced security capabilities Powerful Communications Up to 5 com ports (1 Ethernet and 4 serial) Limitless multi-user connectivity supports Internet, telephone, wireless and more Modbus, TCPIP, UDP, ASCII, and RTU Advanced communications capabilities Industrial Rated to Perform -40 to 70°C operating temperature UL, CSA, CE, DNV, and Zone 2 rated To learn more about our µIPm industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Specs Performance Specifications Industrial PowerPC (32 bit data bus) Operating system embedded open-source Linux Dynamic memory (RAM) 16 Mb for program execution, dynamic variables, dynamic file system, etc. Program memory (Flash) 16 Mb for Linux OS, program storage and file system Retained memory (RAM) 512K (battery-backed) for datalogging and retained variables Real-time clock battery-backed for time stamping and other operations Local I/O (on-board) 12 or 14 (see ordering info.) I/O Expansion (up to 256) RS485 or Ethernet Datalogging support IEC 61131 programming, ISaGRAF for ladder logic, SFC, flow charting and more (6 languages supported) High Level C programming Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols TCP / IP, ARP, UDP, ICNP, DHCP, Modbus / TCP, Sixnet, optionally PPP, DNP3, IEC60870-5-101/104 and more Serial Port Up to 115,200 baud RS485 Port A screws (485+, 485-, GND) (2-wire half-duplex) RS232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) RS232 Port C Screws (TD, RD, RTS, GND) RS232 Port D (optional) Screws (TD, RD, GND) – In place of the two analog inputs Protocols Master and slave modes; Sixnet and Modbus RTU / ASCII; optional: Slave; DNP3, IEC60870-5-101/104. Others available as Linux applications Discrete Inputs 8 channels sourcing or sinking (jumper/software selectable) Guaranteed ON voltage 9 VDC (The threshold is factory adjustable to turn on at a lower voltage – contact Sixnet) Maximum voltage 30 VDC Guaranteed OFF voltage 5.0 VDC and 1.5 mA DC Input resistance and current 10K Ohms and 3 mA @ 24 VDC Filtered ON/OFF delay 25 mS (20 Hz max. counting) for contact bounce filtering Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (see above) (10 KHz on channel 1 only) Count rate (see above) (10 KHz on channel 1 only) Counter modes pulse, rate and run time Poll time (all channels) 5 mS to 20 mS configuration dependent Discrete Outputs 4 channels – sourcing 10-30 VDC Min. and max. output load 1 mA to 1 Amp sourcing per channel Max. OFF state leakage 0.05 mA Inrush current 5 Amps (100 mS surge) Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC voltage drop @ 1A Poll time (all channels) 5 mS to 20 mS configuration dependent Analog Inputs 2 channels – current or voltage selectable Full scale range 4-20 mA or 0-5 VDC (jumper selectable) A/D and input resolution 16 bits (0.003%); 2 uA (current range) or 0.5 mV (voltage range) Full scale accuracy +/-0.1% (@20°C) (factory calibration) Span and offset temp. coeff. +/-50 ppm per °C Input impedance 100 Ohm (current range), 80 K Ohm voltage Current protection Self-resetting fuses (for 4-20 mA range) DMRR 66 dB at 50/60 Hz (differential mode rejection) CMRR (common mode rejection) Not applicable since analog inputs are single ended. Fastest update time 50 mS (both channels) – configurable for longer integration times for better noise filtering Environmental DIN-rail or panel-mount Input power 10-30 VDC Input current 100 mA @ 24 VDC (typical) Temperature -40 to 70°C (-40 to 85°C storage) Humidity 5% to 95% RH (non-condensing) Flammability UL 94V-0 materials Electrical safety UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity EN61326-1 (EN61000-4-2,3,4,6) Surge withstand IEEE-472 (ANSI C37.90) Vibration IEC68-2-6 Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards All specifications are subject to change. Contact Sixnet to learn more. To learn more about our µIPm industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Add I/O Expand the amount of I/O used in your RTU system using Sixnet I/O modules. EtherTRAK-2: Fault-tolerant I/O with dual Ethernet ports and Sixnet's patented ring technology. EtherTRAK: The original Ethernet I/O modules that provide a easy to add I/O to any network RemoteTRAK I/O: Module product line with an RS485 port for easy expandability locally or over long distances RM-8DI2-F: 8, 10-30VDC discrete inputs, field wiring RM-8DI2-U: 8, 10-30VDC discrete inputs, universal wiring RM-16DI2-H: 16, 10-30VDC discrete inputs, high density RM-8DO2-F: 8, 10-30VDC discrete outputs, field wiring RM-16DO2-H: 16, 10-30VDC discrete outputs, high density RM-8AI2-F: 8, 4-20mA analog inputs, 16-bit resolution RM-16AI2-H: 16, 4-20mA analog inputs, 16-bit resolution, high density RM-8INS-U: 8, instrumentation inputs (thermocouples, Volt, 4-20mA, etc.) RM-4AO2-F: 4, 4-20mA analog outputs, 13-bit resolution RM-8AO2-F: 4, 4-20mA analog outputs, 13-bit resolution RM-4DI2-4AI2-U: 4,10-30VDC discrete inputs and 4-20mA analog inputs RM-4DI2-4DO2-U: 4,10-30VDC discrete inputs and discrete outputs RM-RTU-8440-F: Low cost RTU, mix of discrete ins and outs, and analog ins To learn more about our µIPm industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Usage Tips How Much Datalogged Information Can be Stored? Each Sixlog file is allocated a fixed amount of memory. Each record typically contains a time stamp (4 bytes), analog values (2 bytes each), and discrete values (8 per byte). The size of the record is automatically computed and displayed for you by the Sixlog software. The overall storage time (until the oldest data in a full file is overwritten by new data) is computed as: Longest storage = (file size) x (capture interval) / (bytes per record) Example: 16 analog values plus a time stamp ( 32 + 4 = 36 bytes) are logged every 5 minutes into a 400K file. Oldest data = 400,000 (approx) x 5 minutes / 36 bytes/record = 55,555 Minutes (38 days) By default, the Micro-VersaTRAK µIPm has more than 400K for datalogging. Adding I/O to a Micro-VersaTRAK µIPm Industrial RTU Any combination of EtherTRAK and RemoteTRAK I/O modules can be connected to a Micro-VersaTRAK µIPm. A single Micro-VersaTRAK µIPm supports up to 256 EtherTRAK and / or RemoteTRAK I/O. Why Micro-VersaTRAK µIPm Instead of other Sixnet Controllers? Micro-VersaTRAK µIPm offers built-in I/O, Ethernet and up to four serial ports. The embedded LINUX operating system in the Micro-VersaTRAK µIPm offers greater programming flexibility and performance than the legacy VersaTRAK / Mini-VersaTRAK industrial RTUs. To learn more about our µIPm industrial RTU, simply contact [email protected] or call +1 (518) 877-5173. Order Guide Micro-VersaTRAK uIPm Industrial RTU RS RS AO 232 485 Eth Part Number DI DO AI Memory VT-UIPM-431-H 8 4 2 0 2 1 1 16MB Flash & DRAM VT-UIPM-441-H 8 4 0 0 3 1 1 16MB Flash & DRAM IPm2m Industrial RTU & Datalogger RS RS AO 232 485 Eth Part Number DI DO AI Memory VT-IPM2M-113-D 12 4 8 0 1 1 1 32MB Flash & DRAM VT-IPM2M-213-D 12 4 8 2 1 1 1 32MB Flash & DRAM Mini IPm RS RS AO 232 485 Eth Part Number DI DO AI Memory VT-MIPM-131-D 12 8 6 0 2 1 1 512KB NVRAM 16MB Flash & DRAM VT-MIPM-135-D 12 8 6 0 2 1 1 512KB NVRAM 64MB Flash 32MB DRAM VT-MIPM-241-D 12 4 8 2 2 2 1 512KB NVRAM VT-MIPM-245-D 12 4 8 2 2 2 1 16MB Flash & DRAM To learn more about our µIPm industrial RTU, simply contact [email protected] or call +1 (518) 877-5173.