TECHNICAL DATASHEET Rev. A DTA100A-1Y360H 100W AC/DC Desktop Power Supply 90~264 Vac Input 36Vdc Output at 2.78A FEATURES • Single output • 100% Burn-In • Short Circuit Protection • Over Voltage Protection • Over Load Protection • Active PFC Function • IEC-320-C14 AC Inlet Connector • EMC and RoHS Compliant • CEC IV and Energy Star Level V Compliant DESCRIPTION The DTA100A-1Y360H is a 100W, grounded, single phase, switching adapter with active PFC function. The DTA100A-1Y360H has a single output, an input voltage range of 90~264Vac, and an IEC-320-C14 AC inlet connector. This supply is also protected against over load, over voltage, and short circuit conditions. In addition, this supply complies with worldwide safety requirements and electromagnetic compatibility requirements and meets EMC, CEC IV, Energy Star Level V, and RoHS requirements for desktop switching adapters. (888) 597-WALL www.wallindustries.com Page 1 of 6 TECHNICAL DATASHEET Rev. A DTA100A-1Y360H TABLE OF CONTENTS 1. INPUT SPECIFICATIONS ................................................................................................................................3 2. OUTPUT SPECIFICATIONS ............................................................................................................................3 2.1 STATIC DC LOAD, RIPPLE & NOISE .........................................................................................................3 2.2 HOLD UP TIME ..............................................................................................................................................3 2.3 OVERSHOOT AT TURN-ON/TURN-OFF....................................................................................................3 3. PROTECTION .....................................................................................................................................................3 3.1 OVER VOLTAGE PROTECTION .................................................................................................................3 3.2 SHORT CIRCUIT PROTECTION..................................................................................................................3 3.3 OVER LOAD PROTECTION .........................................................................................................................4 4. ENVIRONMENTAL SPECIFICATIONS ........................................................................................................4 4.1 OPERATING ...................................................................................................................................................4 4.2 SHIPPING AND STORAGE...........................................................................................................................4 4.3 TEMPERATURE COEFFICIENT ..................................................................................................................4 5. SAFETY REQUIREMENTS ..............................................................................................................................4 5.1 DIELECTRIC WITHSTAND VOLTAGE ......................................................................................................4 5.2 ISOLATION RESISTANCE ...........................................................................................................................4 6. ELECTROMAGNETIC COMPATIBILITY....................................................................................................4 6.1 FCC REQUIREMENTS ..................................................................................................................................4 6.2 CE REQUIREMENTS.....................................................................................................................................4 7. BURN-IN TEST....................................................................................................................................................4 8. MECHANICAL DIMENSIONS .........................................................................................................................5 8.1 DIMENSIONS .................................................................................................................................................5 8.2 INPUT CONNECTOR.....................................................................................................................................5 8.3 OUTPUT CONNECTOR.................................................................................................................................5 COMPANY INFORMATION ..................................................................................................................................6 (888) 597-WALL www.wallindustries.com Page 2 of 6 TECHNICAL DATASHEET Rev. A 1. INPUT SPECIFICATIONS Description Input Voltage Input Current Line Frequency Inrush Current Power Factor Correction NOTE: 2. DTA100A-1Y360H Min. 90VAC 47Hz - Typical 115/230VAC 50/60Hz 0.9 Max. 264VAC 2.5A 63Hz 150A - Condition 90VAC 50Hz 230VAC Cold Start at full load ● Average efficiency over 85% with 25%, 50%, 75%, 100% load at 115/230VAC. ● No load input < 0.5W. OUTPUT SPECIFICATIONS 2.1 STATIC DC LOAD, RIPPLE & NOISE Nominal Voltage Total Regulation +36VDC +5%, -2% NOTE: Output Current Min. Max. 0A 2.78A Ripple & Noise 480mVp-p ● 20MHz bandwidth ripple & noise is measured by using a 0.1µF C.C. and a 10µF/50V E.C. bypassed at the output connector. ● Regulation shows the percentage of the absolute value of the nominal output voltage. ● Total maximum output power is 100W. 2.2 HOLD UP TIME The power supply unit should maintain its proper output voltage within voltage specifications for at least 16 milliseconds after losing input power under the condition of typical input with full loading. 2.3 OVERSHOOT AT TURN-ON/TURN-OFF Any overshoots during turn-on/turn-off should be less than ±5% of the nominal output voltage. No voltage of opposite polarity should be present on any output during turn-on or turn-off. 3. PROTECTION 3.1 OVER VOLTAGE PROTECTION If any over voltage occurs, the power supply should latch off before any output exceeds its limit shown in the table below. Nominal Voltage +36VDC Over Voltage Range From To +39.6VDC +46.8VDC 3.2 SHORT CIRCUIT PROTECTION Short circuit occurrence on the output should not cause any damage to the power supply but should shut down the power supply. The power supply will automatically recover after the short circuit condition is removed. (888) 597-WALL www.wallindustries.com Page 3 of 6 TECHNICAL DATASHEET Rev. A DTA100A-1Y360H 3.3 OVER LOAD PROTECTION Over load protection will come into effect when overloading reaches 110%~160% max. load. The power supply will automatically recover after the over load condition is removed. 4. ENVIRONMENTAL SPECIFICATIONS 4.1 OPERATING Temperature: 0°C to 40°C Relative Humidity: 20% to 90%, non-condensing 4.2 SHIPPING AND STORAGE Temperature: -10°C to +70°C Relative Humidity: 20% to 90%, non-condensing 4.3 TEMPERATURE COEFFICIENT The temperature coefficient of all outputs is ±0.05%/°C maximum. 5. SAFETY REQUIREMENTS The adapter must comply with UL/CSA/TUV/IEC60950-1 standards. 5.1 DIELECTRIC WITHSTAND VOLTAGE --- Primary to Secondary: 4242VDC for 4 seconds --- Primary to Frame Ground: 2121VDC for 4 seconds 5.2 ISOLATION RESISTANCE 6. --- Primary to Secondary: 20MΩ min / 500VDC --- Primary to Frame Ground: 20MΩ min / 500VDC ELECTROMAGNETIC COMPATIBILITY Tests for conformance to this requirement will be performed with host system. 6.1 FCC REQUIREMENTS This adapter complies with the FCC “Class B” limits. 6.2 CE REQUIREMENTS The adapter complies with the “Class B” requirements of EN55022 & EN55024 for EMS. 7. BURN-IN TEST 100% burn-in tested at max. load under 40±5°C. (888) 597-WALL www.wallindustries.com Page 4 of 6 TECHNICAL DATASHEET Rev. A 8. DTA100A-1Y360H MECHANICAL DIMENSIONS 6.69(L) x 3.35(W) x 1.73(H) inches 8.1 DIMENSIONS: 170(L) X 85.0(W) X 44.0(H) mm 8.2 INPUT CONNECTOR: IEC-320-C14 8.3 OUTPUT CONNECTOR: Depends on customer’s requirements. Unit: inches (mm) 6.69 (170.0) NOTES: 3.35 (85.0) 1. AC Inlet: IEC-320-C14 2. Case Color: Black 3. Tolerance: ± 0.5mm AC INLET 1.73 (44.0) SIDE LABEL (888) 597-WALL 0.08 (2.0) FRONT RUBBER FOOT X 4 www.wallindustries.com Page 5 of 6 TECHNICAL DATASHEET Rev. A DTA100A-1Y360H COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 40 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, welldocumented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: (888) 597-WALL (603)778-2300 (888)587-9255 (603)778-9797 [email protected] www.wallindustries.com 5 Watson Brook Rd. Exeter, NH 03833 www.wallindustries.com Page 6 of 6