RM960 PCB power relays

RM960
PCB power relays
51
• Height 16 mm
• IP 40 or IP 67
• For PCB and sockets (1C/O)
• Accessories: sockets and modules for 1C/O
• Recyclable packing
• Terminals layout patterns: 3,2 - 5,0 - 2,5 - 3,5 mm
Contacts
Contact number & arrangement
Contact material
Max. switching voltage
Min. switching voltage
AC/DC
1C/O, 1NO
AgCdO, AgSnO2, AgCdO/Au 3,5 µm
400 V / 300 V
24 V AgCdO, 24 V AgSnO2,
AgCdO/Au 3,5 µm - contact Relpol S.A.
Rated load
Min. switching current
AC1
8 A / 250 V AC
100 mA AgCdO, 100 mA AgSnO2,
AgCdO/Au 3,5 µm - contact Relpol S.A.
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
AC1
10 A
8A
2 000 VA
2,4 W AgCdO, 2,4 W AgSnO2,
AgCdO/Au 3,5 µm - contact Relpol S.A.
Resistance
Max. operating frequency
• at rated load
• no load
≤ 100 mΩ
AC1
3 600 cycles/hour
20 000 cycles/hour
Coil
Rated voltage
Operating range of supply voltage
Rated power consumption
DC
DC
3...110 V
see Table 1
0,23...0,4 W
Insulation
Insulation category
Insulation rated voltage
Insulation max. voltage
Dielectric strength
• coil - contact
• contact - contact
Contact - coil distance
• clearance
• creepage
C250
250 V AC
400 V AC
4 000 V AC
1 000 V AC
≥ 8 mm
≥ 8 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos φ = 0,4
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storing
• operating
Cover protection category
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
Standard contact material marked with bolt type.
www.relpol.com.pl
9 ms
3 ms
> 105
8 A, 250 V AC
> 105
5 A, 250 V AC
> 3 x 107
29 x 10 x 15 mm
10 g
-40...+80 oC
-40...+70 oC
IP 67
10 g
10 g 45...100 Hz
max. 270 oC
max. 5 s
RM960
PCB power relays
52
www.relpol.com.pl
RM960
PCB power relays
53
Mounting
Relays RM960 1NO are mounted anly on PCBs.
Relays RM960 1C/O (3,2 mm pinning) are designed for:
• direct PCB mounting • screw terminals sockets GZ96
with clip MS16, 35 mm DIN rail mount, EN 50022 or on
panel mounting. M... type signalling and protection
plug-in modules are available with sockets (see page 170)
• terminals sockets for PCB mounting GW96 with clip
MH16-2.
see Table 1 page 52
www.relpol.com.pl