Filename: 469.doc version 3.0 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedances * Input: Output: 26.09.2002 Filter Specification TFS 469 1/5 23 °C 0 dBm 270 Ω || -1pF 270 Ω || -1pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS469 is the maximum of the attenuation within the usable signal bandwidth amax. The maximum of the attenuation within the usable signal bandwidth is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 469,99 MHz without tolerance. The given values for the relative attenuation have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. D a t a typ. value 3,6 dB Variation / Limitation max. 5 Insertion loss (Reference level) ae = amax Nominal frequency fN - Centre frequency fc 469,99 MHz - 3 dB - bandwidth BW 265 kHz - Usable signal bandwidth Relative attenuation fN + 910 kHz fN ± 0,7 MHz ... fN ± 10 dB 469,99 MHz - min. fN ±10 kHz - min. min. dB dB arel MHz Temperature coefficient of frequency TCf ** Frequency inversion temperature T0 -0,036 ppm/K2 + 25 °C 52 40 - Operating temperature range - - 10°C ... + 50°C Storage temperature range - - 40°C ... + 85°C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) generated: checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 469.doc version 3.0 VI TELEFILTER 26.09.2002 Filter Specification TFS 469 2/5 Construction and pin connection (All dimensions in mm) 1 2 3 4 5 6 7 8 9 10 Datecode M N P ... Ground Ground Ground Ground Output Ground Ground Ground Ground Input Year + week 2000 2001 2002 50 Ω test circuit 1 L1 10 5 C1 L2 C2 1,2,3,4 6,7,8,9 50 Ω test circuit 2 C1 C2 10 5 L1 L2 1,2,3,4 6,7,8,9 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 469.doc version 3.0 VI TELEFILTER 26.09.2002 Filter Specification TFS 469 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 1,5 mm or 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : 0,6 P2 : 2 ± 0,1 P1 ± 0,1 EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 : 8 D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 9,7 ± 0,1 CT : 13,5 + 0,1 3000 min 300 mm min 500 mm min 300 mm CT W Bo G P1 COVER TAPE W 2 Reel (all dimensions in mm): A W1 : : 330 16,4 +2 W2 (max) : 22,4 N (min) : 50 C : 13 + 0,5 / - 0,2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 469.doc version 3.0 VI TELEFILTER 26.09.2002 Filter Specification TFS 469 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 469.doc VI TELEFILTER version 3.0 Filter Specification 26.09.2002 TFS 469 5/5 History Version Reason of Changes Name Date 3.0 Add history. Change remark for characteristic. Add remark for termination impedance. Change footprint of package. Correct stability characteristics. Correct packing information. Dr. Wall 26.09.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.