Filename: tfs 248c.doc Version 1.4 VI TELEFILTER 06.08.2004 Filter specification TFS 248C 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 63 Ω || -1,65 pF 63 Ω || -0,42 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 248C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3,0 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 248,6 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. Value Insertion Loss (reference level) ae = amin Nominal Frequency fN Centre Frequency fC Tolerance / Limit 1,9 dB 3,5 dB - 248,6 MHz 248,6 MHz - 3 dB Band width 6,6 MHz 5,0 MHz Pass Band Ripple fN ± 120 kHz 0,05 dB 0,5 dB Relative Attenuation fN – 248,5 MHz fN + 10 MHz fN + 21 MHz Group Delay arel ... fN – 12 MHz ... fN + 21 MHz ... fN + 251,4 MHz GD Group Delay Ripple fN ± 120 kHz 35-80 dB 18-40 dB 40-60 dB dB dB dB ns max. 300 ns 10 ns max. 100 ns max. dBm Operating Temperature Range Temperature Coefficient 25 10 25 150 Input Power Level Storage Temperature Range min. min. min –36 ppm/K 12 - 25 °C ... + 75 °C - 40 °C ... + 85 °C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 248c.doc Version 1.4 VI TELEFILTER 06.08.2004 Filter specification TFS 248C 2/5 Filter characteristic 0 0 0.5 -0.5 -10 0.45 -1 0.4 -20 -40 -50 0.35 -2 0.3 -2.5 0.25 -3 0.2 -3.5 delay in µs -30 magnitude in dB magnitude in dB -1.5 0.15 -60 -4 -70 0.1 -4.5 -80 100 150 200 250 frequency in MHz 300 -5 350 0.05 244 245 246 247 248 249 250 frequency in MHz 251 252 253 0 Construction and pin connection (All dimensions in mm) TFS 248C ● S32 1 2 3 4 5 6 7 8 9 10 Input Ground Ground Ground Ground Output Output Ground Ground Ground Date code: S T U ... Year + week 2004 2005 2006 50/200 Ω Test circuit 1 6 L2 C2 7 L4 2, 3, 4, 5, 8, 9, 10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 248c.doc Version 1.4 VI TELEFILTER 06.08.2004 Filter specification TFS 248C 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direc tion Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 7,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 ± 0,10 Bo : 9,60 ± 0,10 Ct : 13,5 P1 t Date Code Po P2 W G Ct Bo F G E Do Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 248c.doc Version 1.4 VI TELEFILTER 06.08.2004 Filter specification TFS 248C 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 248c.doc VI TELEFILTER Version 1.4 Filter specification 06.08.2004 TFS 248C 5/5 History Version Reason of Changes Name Date 1.4 - add filter characteristic - change drawing of package (construction, pin connection) - change drawing of packing (tape and reel) Noack 06.08.04 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.