Tfs240C.doc version 1.0 12.4.01 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 240C 1/5 ______________________________________________________________________________________________________ Measurement condition Ambient temperature: Input power level: Terminating impedance: source: load: 23 °C 0 dBm t.b.d. t.b.d. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 240C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed to 240 MHz. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. Value Limit ______________________________________________________________________________________________________ Insertion Loss ae = amin 12 ... 16 dB (Reference Level) ______________________________________________________________________________________________________ Nominal Frequency 240,0 MHz fN ______________________________________________________________________________________________________ Pass band fN 0,55 MHz... fN + 0,55 MHz Pass band ripple max 1,0 dB Group delay ripple - max 0,2 µs Average pass-band delay Maximum variation between devices over temperature range - max. 3,5 µs max.+/- 100 ns Phase linearity - max Return loss - min 4,0 deg p-p 12 dB ______________________________________________________________________________________________________ Relative Attenuation fN ± 550 kHz arel - max. 1 dB fN ± 900 kHz ... fN ± 1,25 MHz min. 10 dB fN ± 1,25 MHz ... fN ± 1,7 MHz min 25 dB fN ± 1,7 MHz ... fN ± 2,5 MHz min 35 dB fN ± 2,5 MHz... fN ± 70 MHz min 40 dB ______________________________________________________________________________________________________ Operating Temperature Range -10 ... 85° C ______________________________________________________________________________________________________ Storage Temperature Range -40 ... 85° C ______________________________________________________________________________________________________ Input power max. 10 dBm ______________________________________________________________________________________________________ Temperature Coefficient - 0,036 ppm / K2 TC ______________________________________________________________________________________________________ generated: checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs240C.doc version 1.0 12.4.01 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 240C 2/5 ______________________________________________________________________________________________________ Construction and pin connection (All dimensions in mm) 15,32 ±0,20 TFS240C N14 1,0 1 Datecode 1 2 3 4 5 6 7 8 9 10 6,50 ±0,20 2,0Max. 0,2 120° 1,9 1,91 7,62 0,2 Input RF return Ground Ground Ground Output Output RF return Ground Ground Ground Input 0,2 Datecode: L M N ... 0,2 Year+week 1999 2000 2001 50 Ω matching circuit L1 L2 10 Input 50 Ohm 5 Output 50 Ohm SAW C1 C2 1,2,3,4,6,7,8,9 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs240C.doc version 1.0 12.4.01 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 240C 3/5 ______________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 – 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 – 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 – 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached “Air reflow temperature conditions” on page 4; Packing Tape & Reel: DIN IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po Do E : : : : 24 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 F : G (min) : 11,5 ± 0,1 0,60 P2 : P1 : D1(min) : Ao : 2 12 1,5 7,1 ± 0,1 ± 0,1 15,9 21,5 ± 0,2 ± 0,1 Bo Ct : : 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 Ct W Bo G ± 0,2 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 24,40 +2,0 30,4 60 C C : 13 A 0,5/-0.2 N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs240C.doc version 1.0 12.4.01 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 240C 4/5 ______________________________________________________________________________________________________ Air reflow temperature conditions st 1 and 2 nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C – 170 °C 60 sec. – 90 sec. main-heating periods over 200 °C 20 sec. – 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. Time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 Temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs240C.doc version 1.0 12.4.01 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 240C 5/5 ______________________________________________________________________________________________________ History Version Reason of Changes Name Date 1.0 - new generation according to customer specification V0.6 Steiner 12.04.2001 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.