VECTRON TFS240C

Tfs240C.doc
version 1.0
12.4.01
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 240C
1/5
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
source:
load:
23 °C
0 dBm
t.b.d.
t.b.d.
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 240C is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed to 240 MHz. The given values for the relative attenuation arel
and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature
coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. Value
Limit
______________________________________________________________________________________________________
Insertion Loss
ae = amin
12 ... 16
dB
(Reference Level)
______________________________________________________________________________________________________
Nominal Frequency
240,0 MHz
fN
______________________________________________________________________________________________________
Pass band
fN 0,55 MHz... fN +
0,55 MHz
Pass band ripple
max
1,0 dB
Group delay ripple
-
max
0,2 µs
Average pass-band delay
Maximum variation between devices over temperature range -
max.
3,5 µs
max.+/- 100 ns
Phase linearity
-
max
Return loss
-
min
4,0 deg p-p
12
dB
______________________________________________________________________________________________________
Relative Attenuation
fN ± 550
kHz
arel
-
max.
1
dB
fN ± 900
kHz ... fN ±
1,25 MHz
min. 10
dB
fN ±
1,25 MHz ... fN ±
1,7 MHz
min
25
dB
fN ±
1,7 MHz ... fN ±
2,5 MHz
min
35
dB
fN ±
2,5 MHz... fN ± 70
MHz
min
40
dB
______________________________________________________________________________________________________
Operating Temperature Range
-10 ... 85° C
______________________________________________________________________________________________________
Storage Temperature Range
-40 ... 85° C
______________________________________________________________________________________________________
Input power
max. 10
dBm
______________________________________________________________________________________________________
Temperature Coefficient
- 0,036 ppm / K2
TC
______________________________________________________________________________________________________
generated:
checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs240C.doc
version 1.0
12.4.01
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 240C
2/5
______________________________________________________________________________________________________
Construction and pin connection
(All dimensions in mm)
15,32 ±0,20
TFS240C
N14
1,0
1
Datecode
1
2
3
4
5
6
7
8
9
10
6,50 ±0,20
2,0Max.
0,2
120°
1,9
1,91
7,62
0,2
Input RF return
Ground
Ground
Ground
Output
Output RF return
Ground
Ground
Ground
Input
0,2
Datecode:
L
M
N
...
0,2
Year+week
1999
2000
2001
50 Ω matching circuit
L1
L2
10
Input
50 Ohm
5
Output
50 Ohm
SAW
C1
C2
1,2,3,4,6,7,8,9
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs240C.doc
version 1.0
12.4.01
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 240C
3/5
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 – 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 – 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 – 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached “Air reflow temperature conditions” on page 4;
Packing
Tape & Reel:
DIN IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
E
:
:
:
:
24
± 0,3
4
± 0,1
1,5 + 0,1
1,75 ± 0,1
F
:
G (min) :
11,5 ± 0,1
0,60
P2
:
P1
:
D1(min) :
Ao
:
2
12
1,5
7,1
± 0,1
± 0,1
15,9
21,5
± 0,2
± 0,1
Bo
Ct
:
:
2000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
Ct
W
Bo
G
± 0,2
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
24,40 +2,0
30,4
60
C
C
:
13
A
0,5/-0.2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs240C.doc
version 1.0
12.4.01
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 240C
4/5
______________________________________________________________________________________________________
Air reflow temperature conditions
st
1 and 2
nd
air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C – 170 °C
60 sec. – 90 sec.
main-heating periods
over 200 °C
20 sec. – 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. Time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
Temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
Temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs240C.doc
version 1.0
12.4.01
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 240C
5/5
______________________________________________________________________________________________________
History
Version
Reason of Changes
Name
Date
1.0
- new generation according to customer specification V0.6
Steiner
12.04.2001
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.