File name : TFH36B.doc Version 1.1 VI TELEFILTER Filter Specification 13.03.2001 TFH 36B 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 25 °C 0 dBm. for input: 50 Ω 0 pF. for output: 50 Ω 0 pF. 2. Characteristics Remark: The insertion loss ae is defined as the insertion loss at the nominal frequency fN . Reference level for the relative attenuation arel of the TFS 36B is the insertion loss. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the centre frequency fc and the frequency response of the filter in the operating temperature range. Data typical values Insertion loss (Reference level) Nominal frequency Centre frequency ae 26,7 dB max. fC ... fC ± 2,8 MHz dB - band width dB - band width dB - band width dB - band width dB - band width 2,80 5,0 0,25 dB max. 0,55 dB 7,45 7,63 8,08 9,35 9,80 min. 5,6 MHz min. 8,0 MHz max. 10,0 MHz at ambient temperature: Relative attenuation fN fN ± fN ± dB 36,125 MHz Amplitude ripple in PB (p-p) : 0,55 1 3 20 35 27,5 36,125 MHz fN fC Pass band (PB) : Bandwidth tolerance / limit MHz MHz MHz MHz MHz arel 2,80 ... fN ± MHz ... fN ± 4,0 MHz ... fN ± 30 MHz MHz MHz 0,25 dB < 2,6 dB 40...45 dB Group delay ( mean value in PB ) Group delay ripple in fN ... fN ± 2,8 MHz (p-p) *) Deviation from linear phase in fN ... fN ± 2,8 MHz (p-p) 1,45 µs 26 ns 1,6° ( r.m.s. 0,3° ) Triple transit attenuation compared to main signal Crosstalk 60 65 Temperature coefficient of frequency ( Tcf ) Frequency deviation of fN over temperature : Operating temperature range Storage temperature range max. max. min. 0,55 dB 3 dB 35 dB max. max. max. 2 70 3° µs ns dB dB - 75 ppm/K ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fN (MHz) 25 °C - 25 °C ... + 85 °C * ) measured with smoothing aperture of 120 kHz. Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name : TFH36B.doc Version 1.1 VI TELEFILTER Filter Specification TFH 36B 13.03.2001 2/5 3. Package : (All dimensions in mm) pin grid 2,54 mm 27,18 Max. 13 max. 5,08 max. 0,64 4,58 min. 0,46 Dia. 2,54 ± 0,2 8x2,54 = 20,32 TFH tft 1 7,62 Datecode: L M N .... 36B N04 2 Year+week 1999 2000 2001 ........ 9 Pin 18 Pin 1 Pin 9 Pin 10 Pin 2, 11 4,57 Input Input RF Return Output Output RF Return Package Ground 17,27 18 11 10 4. 50 Ω matching networks : 1 2 9 50 Ω 50 Ω 18 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] 11 10 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name : TFH36B.doc Version 1.1 VI TELEFILTER Filter Specification 13.03.2001 TFH 36B 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name : TFH36B.doc Version 1.1 VI TELEFILTER Filter Specification 13.03.2001 TFH 36B 4/5 6. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name : TFH36B.doc VI TELEFILTER Version 1.1 Filter Specification 13.03.2001 TFH 36B 5/5 7. History : Version Reason of Changes Name Date 1.0 Generate extended filter specification. Dunzow W. 09.03.2001 1.1 Correct definition of insertion loss. Correct typical filter data. Reduce max. pass band ripple from 0,6 dB to 0,55 dB. Dunzow / Wall 13.03.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.