VECTRON TFH36B

File name : TFH36B.doc
Version 1.1
VI TELEFILTER
Filter Specification
13.03.2001
TFH 36B
1/5
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances at fc:
25 °C
0 dBm.
for input:
50 Ω  0 pF.
for output:
50 Ω  0 pF.
2. Characteristics
Remark:
The insertion loss ae is defined as the insertion loss at the nominal frequency fN . Reference level for the relative attenuation arel of the TFS 36B
is the insertion loss. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the centre frequency fc and the frequency response
of the filter in the operating temperature range.
Data
typical values
Insertion loss (Reference level)
Nominal frequency
Centre frequency
ae
26,7 dB
max.
fC ... fC ± 2,8 MHz
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
2,80
5,0
0,25 dB
max.
0,55
dB
7,45
7,63
8,08
9,35
9,80
min.
5,6
MHz
min.
8,0
MHz
max.
10,0
MHz
at ambient temperature:
Relative attenuation
fN
fN ±
fN ±
dB
36,125 MHz
Amplitude ripple in PB (p-p) :
0,55
1
3
20
35
27,5
36,125 MHz
fN
fC
Pass band (PB) :
Bandwidth
tolerance / limit
MHz
MHz
MHz
MHz
MHz
arel
2,80
... fN ±
MHz ... fN ±
4,0
MHz ... fN ± 30
MHz
MHz
MHz
0,25 dB
< 2,6 dB
40...45
dB
Group delay ( mean value in PB )
Group delay ripple in fN ... fN ± 2,8 MHz (p-p) *)
Deviation from linear phase in fN ... fN ± 2,8 MHz (p-p)
1,45 µs
26
ns
1,6° ( r.m.s. 0,3° )
Triple transit attenuation compared to main signal
Crosstalk
60
65
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fN over temperature :
Operating temperature range
Storage temperature range
max.
max.
min.
0,55 dB
3
dB
35
dB
max.
max.
max.
2
70
3°
µs
ns
dB
dB
- 75
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fN (MHz)
25 °C
- 25 °C ... + 85 °C
* ) measured with smoothing aperture of 120 kHz.
Generated:
Dunzow W.P.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name : TFH36B.doc
Version 1.1
VI TELEFILTER
Filter Specification
TFH 36B
13.03.2001
2/5
3. Package : (All dimensions in mm)
pin grid 2,54 mm
27,18 Max.
13 max.
5,08 max.
0,64
4,58 min.
0,46 Dia.
2,54 ± 0,2
8x2,54 = 20,32
TFH
tft
1
7,62
Datecode:
L
M
N
....
36B
N04
2
Year+week
1999
2000
2001
........
9
Pin 18
Pin 1
Pin 9
Pin 10
Pin 2, 11
4,57
Input
Input RF Return
Output
Output RF Return
Package Ground
17,27
18
11 10
4. 50 Ω matching networks :
1
2
9
50 Ω
50 Ω
18
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
11 10
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name : TFH36B.doc
Version 1.1
VI TELEFILTER
Filter Specification
13.03.2001
TFH 36B
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name : TFH36B.doc
Version 1.1
VI TELEFILTER
Filter Specification
13.03.2001
TFH 36B
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name : TFH36B.doc
VI TELEFILTER
Version 1.1
Filter Specification
13.03.2001
TFH 36B
5/5
7. History :
Version
Reason of Changes
Name
Date
1.0
Generate extended filter specification.
Dunzow W.
09.03.2001
1.1
Correct definition of insertion loss.
Correct typical filter data.
Reduce max. pass band ripple from 0,6 dB to 0,55 dB.
Dunzow / Wall
13.03.2001
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.