VRLA Rechargeable Battery Measures MSB-200 Technology Values Innovation (2V, 200Ah) APPLICATION FEATURES Sealed structure, no electrolyte leakage or spill. High performance alloy to secure corrosion-proof feature. Unique electrolyte system achieves maximum service life. Low self-discharge rate, lower than 3% capacity loss per month. Special paste formula promotes the good charging acceptance. Electrolyte with gel technology. Telecom UPS Central Office Energy Storage Systems SPECIFICATIONS Nominal Voltage Nominal Capacity Approx. Weight Terminals Internal Resistance Max. Discharge Current Max. Charge Current 2V 200Ah @ 10 hour rate F.V.(1.80V/cell) 16.0Kg(35.3lbs.) B6 (Fitting M8 bolt & nut) I3 is optional (Fully Charged ) 1.0m 900 A (5 sec.) 50 A Charge 0oC~40oC(32oF~104oF) Discharge -20oC~50oC(-4oF~122oF) Storage. -20oC~40oC(-4oF~104oF) Operating Temperature Range Safety Valve IEC60896-21/22 JIS C 8704-2 GB/T19638.2 YD/T799 Opening pressure 10~35 kPa Standard: ABS( UL 94-HB) MSB-200 Optional: Flame Retardant ABS(UL 94-V0) MSB-200FR Container Material DIMENSION(mm/inch) OUTER DIMENSIONS TERMINAL TYPE Length Terminal I3 Terminal B6 173±2.0 (6.81±0.08) M8x1.25 111 2 (4.37 0.08) Container Height 329±2.0 (12.95±0.08) Total Height 357±2.0 (14.06±0.08) 10.5(0.39) 357 2 (14.06 0.08) 329 2 (12.95 0.08) 111±2.0 (4.37±0.08) 7.7(0.30) (M8 BOLT & NUT) (M8 BOLT) Terminal Hardware Initial Torque: 10.0 Nm ± 5% Constant power discharge characteristics at 25 oC/77 oF Discharge Time 25.5(1.00) 6.0(0.24) 0.08) 8.5(0.33) 2 (6.81 28.0(1.10) 173 Width Unit: W 30 Min 1 Hr 2 Hr 3 Hr 4 Hr 5 Hr 6 Hr 8 Hr 10 Hr 12 Hr 20 Hr 1.85V 262.3 180.0 115.8 90.2 70.1 60.4 53.8 44.5 37.2 32.24 20.09 1.80V 291.0 198.0 125.0 95.5 77.2 65.8 57.3 47.6 39.4 33.80 21.10 1.75V 318.8 210.0 132.5 100.6 80.9 68.8 59.8 49.1 41.1 34.95 21.70 1.70V 350.0 224.0 137.0 104.0 82.5 70.5 61.3 50.1 42.5 35.77 22.05 1.65V 376.0 231.0 139.0 106.2 84.2 71.5 62.5 51.0 43.1 36.28 22.24 1.60V 383.5 233.0 141.0 107.2 85.2 72.5 62.8 51.6 43.5 36.44 22.30 F.V. (V/cell) o o Constant current discharge characteristics at 25 C/77 F Discharge Time Unit: A 30 Min 1 Hr 2 Hr 3 Hr 4 Hr 5 Hr 6 Hr 8 Hr 10 Hr 12 Hr 20 Hr 1.85V 140.0 96.0 61.0 47.2 37.0 31.3 27.0 22.0 18.7 16.21 10.10 1.80V 156.0 106.0 66.0 50.0 40.8 34.0 29.0 24.2 20.0 17.17 10.70 1.75V 172.3 113.0 70.3 52.9 42.8 36.0 31.0 25.3 21.1 17.94 11.13 1.70V 191.0 121.2 73.3 55.2 43.9 37.2 32.0 26.2 21.9 18.43 11.45 1.65V 204.5 126.1 75.3 57.0 45.0 38.2 33.2 27.0 22.3 18.67 11.60 27.5 22.5 18.84 11.63 F.V. (V/cell) All data shall be changed prior notice, BB reserves to explain and update 1.60V 215.0 without129.3 77.5 the right 58.2 45.8 the information 38.8contained hereinto. 33.5 All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. A/2 REV. Dec. 2013 Powered by B.B. Battery Co., Ltd.