QT-D/E 2x10-13/230-240

QUICKTRONIC®
ECG for compact and tubular fluorescent lamps
Technical
Information
QT-D/E 2x10-13/230-240
Edition: February 2007
subject to change
Produkteigenschaften:
•
•
•
•
•
•
•
•
Pre-heat start, suitable for applications in which lamps are switched on and
off frequently
Constant flicker-free light without stroboscopic effects
CELMA energy classification EEI = A2
50,000 hours lifetime with 10 % max. failure rate at tc = 70 °C max.
Reliable lamp ignition between -15 °C...+50 °C
Reliable and safe shutdown of defective lamps
Automatic restart after lamp replacement
Suitable for emergency installations (DC operation)
Technische Daten:
Reference:
Lamps:
DULUX S/E 9W 1)
DULUX D/E 10 W
DULUX S/E 11 W
DULUX D/E 13 W
DULUX T/E 13 W
HF-Lamp wattage:
[WHF]
18
20
22
26
26
Preheating time:
Supply voltage:
Voltage range (AC):
Voltage range (DC):
Rated frequency:
Inrush current:
Max. number of EVG, circuit breaker
10 A, char. B
Max. number of EVG, circuit breaker
16 A, char. B
Operating frequency:
Power factor:
Temperature range ta:
Case temperature tc:
Dimensions (l x w x h):
Distance between mounting holes:
Weight:
Safety:
Radio interference:
Harmonic content:
Immunity:
Packaging unit:
Approval marks:
1)
2)
QT-D/E 2x10-13/230-240
System wattage:
Line current:
Luminous flux at 25 °C:
[W]
[A]
[lm]
20
0.09
2x 640
20
0.09
2x 600
25
0.11
2x 850
25
0.11
2x 850
25
0.11
2x 850
t < 1.5 sec. 2)
230 V – 240 V
207 V – 254 V
176 V – 254 V; for lamp ignition min. 198 V
0/50-60 Hz
Ip = 13 A; TH = 320 μs
17
28
ca. 40 kHz
λ = 0.99c
-15 °C to +50 °C
max. +70 °C
K3 (123 x 79 x33 mm)
129,5 mm
220 g
acc. to EN 61347-2-3 / IEC 61347-2-3
acc. to EN 55015 / CISPR 15
acc. to EN 61000-3-2 / IEC 61000-3-2
acc. to EN 61547 / IEC 61547
20 pieces
Lamp combination without ENEC approbation
If there is a temporary interruption in the power supply (< 0.5 sec.) the lamp will start within 0.3 sec.
QUICKTRONIC®
ECG for compact and tubular fluorescent lamps
Technical Technische
Vorläufige
Information
QT-D/E 2x10-13/230-240
Edition: February
Ausgabe:
Juni2006
Juli
2006
2007
Änderungen
subject
to change
vorbehalten
Product:
QT-D/E 2x10-13/230-240
Product number:
Product number
QT-D/E 2x10-13/230-240
EAN 10 / Single unit (1 pc.)
4050300 312538
EAN 40 / Package unit (20 pcs.)
4050300 312545
Lamp wiring:
220...
240 V
QT-D/E 2x10-13
~
1
2
3
4
5
6
7
L
L