QUICKTRONIC® ECG for compact and tubular fluorescent lamps Technical Information QT-D/E 2x10-13/230-240 Edition: February 2007 subject to change Produkteigenschaften: • • • • • • • • Pre-heat start, suitable for applications in which lamps are switched on and off frequently Constant flicker-free light without stroboscopic effects CELMA energy classification EEI = A2 50,000 hours lifetime with 10 % max. failure rate at tc = 70 °C max. Reliable lamp ignition between -15 °C...+50 °C Reliable and safe shutdown of defective lamps Automatic restart after lamp replacement Suitable for emergency installations (DC operation) Technische Daten: Reference: Lamps: DULUX S/E 9W 1) DULUX D/E 10 W DULUX S/E 11 W DULUX D/E 13 W DULUX T/E 13 W HF-Lamp wattage: [WHF] 18 20 22 26 26 Preheating time: Supply voltage: Voltage range (AC): Voltage range (DC): Rated frequency: Inrush current: Max. number of EVG, circuit breaker 10 A, char. B Max. number of EVG, circuit breaker 16 A, char. B Operating frequency: Power factor: Temperature range ta: Case temperature tc: Dimensions (l x w x h): Distance between mounting holes: Weight: Safety: Radio interference: Harmonic content: Immunity: Packaging unit: Approval marks: 1) 2) QT-D/E 2x10-13/230-240 System wattage: Line current: Luminous flux at 25 °C: [W] [A] [lm] 20 0.09 2x 640 20 0.09 2x 600 25 0.11 2x 850 25 0.11 2x 850 25 0.11 2x 850 t < 1.5 sec. 2) 230 V – 240 V 207 V – 254 V 176 V – 254 V; for lamp ignition min. 198 V 0/50-60 Hz Ip = 13 A; TH = 320 μs 17 28 ca. 40 kHz λ = 0.99c -15 °C to +50 °C max. +70 °C K3 (123 x 79 x33 mm) 129,5 mm 220 g acc. to EN 61347-2-3 / IEC 61347-2-3 acc. to EN 55015 / CISPR 15 acc. to EN 61000-3-2 / IEC 61000-3-2 acc. to EN 61547 / IEC 61547 20 pieces Lamp combination without ENEC approbation If there is a temporary interruption in the power supply (< 0.5 sec.) the lamp will start within 0.3 sec. QUICKTRONIC® ECG for compact and tubular fluorescent lamps Technical Technische Vorläufige Information QT-D/E 2x10-13/230-240 Edition: February Ausgabe: Juni2006 Juli 2006 2007 Änderungen subject to change vorbehalten Product: QT-D/E 2x10-13/230-240 Product number: Product number QT-D/E 2x10-13/230-240 EAN 10 / Single unit (1 pc.) 4050300 312538 EAN 40 / Package unit (20 pcs.) 4050300 312545 Lamp wiring: 220... 240 V QT-D/E 2x10-13 ~ 1 2 3 4 5 6 7 L L Max. permitted cable length in between EVG and lamp: 2.0 m (PIN 1;2;3;5); 1.0 m (PIN 6;7)