QUICKTRONIC PROFESSIONAL QTP5 osram.com QUICKTRONIC PROFESSIONAL QTP5 ECG for T5/16mm, T8/26mm, DULUX L fluorescent lamps QTP5 ® i.e. LUMILUX T5 HO ES GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 01 QUICKTRONIC PROFESSIONAL QTP5 Product Features: Up to 100.000 hours lifetime1 Lamp start with optimized filament preheating within 1 sec. Suitable for lighting with very high switching cycles Reliable lamp ignition between -20°C...+50°C Cut-off Technology Suitable for luminaries of protection classes I and II2 CELMA Energy Efficiency Index A2 BAT (Best Available Technology)3 Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2) Automatic restart after lamp replacement Suitable for emergency installations (DC operation) Technical Data Max. cable diameter for IDC-contakt [mm2]: „s“4: 0.5; „f“5: 0.75 Max. cable diameter for push-in contact [mm2]: „s“4: 0.5…1.0 Starting time: t: < 1 sec. (<0.3 sec. in case of line interruptions/switchover of <0.5 sec.) Line voltage: 220 - 240 V Voltage range (AC): 198 - 264 V Voltage range (DC): 176 - 276 V Line frequency: 0, 50 - 60 Hz Operating frequency: Electrical strength: 40 - 50 kHz 300 V permanent, 320 V 48 hours, 350 V 2 hours Ambient temperature ta: -20 °C to +50 °C Measuring point temperature tc: U-OUT: 1 2 3 4 5 Max. +75 °C 330 V 430 V QTP5 1x14-35 QTP5 2x14-35 QTP5 1x24-39 QTP5 2x24-39 QTP5 1x49 QTP5 2x49 QTP5 1x54 QTP5 2x54 QTP5 1x80 QTP5 3x14, 4x14 at T = 65°C @ Tc. 50.000 h with max. 10% failure rate at tc = 75°C max No need to connect (functional) earth in suitable luminaires of protection class II EEI: A2 for QTP5 1x24-39 “s” = solid wire “f” = flexible wire GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 02 QUICKTRONIC PROFESSIONAL QTP5 Inrush current and max. number of ECG per circuit breaker ECG QTP5 QTP5 QTP5 QTP5 QTP5 QTP5 QTP5 QTP5 QTP5 QTP5 Inrush Current 1x14-35 2x14-35 3x14, 4x14 1x24-39 2x24-39 1x49 2x49 1x54 2x54 1x80 Ip [A] 24 40 40 24 40 24 53 40 53 40 Max. number of ECG per circuit breaker TH [µs] 230 200 200 230 200 230 190 200 190 200 B: 10A 17 12 12 17 12 17 8 12 8 12 B: 16A 28 19 19 28 19 28 13 19 13 19 C: 16 A 47 32 32 47 32 47 21 32 21 32 Standards and approval marks Safety: acc. to EN 61347-2-3 / IEC 61347-2-3 Radio interference: acc. EN 55015: 2006 + A1: 2007 + A2: 2009 Harmonic content: acc. to EN 61000-3-2 / IEC 61000-3-2 Immunity: acc. to EN 61547 / IEC 61547 Approval marks: Dimensions & weight Description Description Length [mm] width [mm] height [mm] distance Weight [g] mounting holes [mm] QTP5 1x14-35 280 30 21 270 180 QTP5 2x14-35 360 30 21 350 255 QTP5 3x14, 4x14 280 40 21 270 240 QTP5 1x24-39 280 30 21 270 180 QTP5 2x24-39 360 30 21 350 255 QTP5 1x49 280 30 21 270 180 QTP5 2x49 360 30 21 350 255 QTP5 1x54 280 30 21 270 180 QTP5 2x54 360 30 21 350 255 QTP5 1x80 360 30 21 350 255 GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 03 QUICKTRONIC PROFESSIONAL QTP5 Lamp wiring QTP5 1x… Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24) QTP5 2x… Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22, 25, 26); 1.0 m (PIN 23, 24) QTP5 3x14, 4x14 – 3 lamp operation Max. permitted cable length in between ECG and lamp: 1.5 m (PIN 4, 5, 21, 22, 23, 24); 1.0 m (PIN 6, 7, 25, 26) GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 04 QUICKTRONIC PROFESSIONAL QTP5 QTP5 3x14, 4x14 – 4 lamp operation 1 ~ 2 3 ~ 220... 240 V QTP5 3x14, 4x14 4 5 6 7 21 22 23 24 25 26 L L L L Max. permitted cable length in between ECG and lamp: 1.5 m (PIN 4, 5, 21, 22, 23, 24); 1.0 m (PIN 6, 7, 25, 26) Logistic Data Description EAN 10 EAN 40 Packaging Unit QTP5 1x14-35 4008321329035 4008321329042 20 QTP5 2x14-35 4008321329073 4008321329080 20 QTP5 3x14, 4x14 4008321484598 4008321484604 20 QTP5 1x24-39 4008321329110 4008321329127 20 QTP5 2x24-39 4008321329417 4008321329424 20 QTP5 1x49 4008321329370 4008321329387 20 QTP5 2x49 4008321123831 4008321123848 20 QTP5 1x54 4008321329394 4008321329400 20 QTP5 2x54 4008321329097 4008321329103 20 QTP5 1x80 4008321329059 4008321329066 20 Lifetime Measuring point temperature tc: Lifetime with max. 10% failure rate 75 °C 50,000 h 65 °C 100,000 h GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 05 QUICKTRONIC PROFESSIONAL QTP5 Lamp/ECG System Combination ECG QTP5 1x14-35 QTP5 2x14-35 QTP5 3x14, 4x14 Lamp HE 14 HE 21 HE 28 HE 35 DL28 HE 13 ES6 HE 19 ES6 HE 25 ES6 HE 32 ES6 DL 16 HE6 DL 22 HE6 DL 26 HE6 2x HE14 2x HE21 2x HE28 2x HE35 2x DL28 2x HE 13 ES6 2x HE 19 ES6 2x HE 25 ES6 2x HE 32 ES6 2x DL 16 HE6 2x DL 22 HE6 2x DL 26 HE6 3x HE14 4x HE14 3x HE 13 ES6 4x HE 13 ES6 HF lamp wattage [W] 14 21 28.5 35 28 13 19 25 32 15 22 26 2x 13.5 2x 20.5 2x 28 2x 34.5 2x 28 26 38 50 64 32 44 52 3x 14 4x 14 3x 12.9 4x 12.5 System wattage [W] 16 24 31 38 31 15 22 27 34 18 24 29 30 45 60 75 60 28 42 54 68 34 48 57 48 63 43 56 Line current [A] 0.08 0.11 0.14 0.17 0.14 0.075 0.10 0.12 0.15 0.08 0.11 0.13 0.14 0.20 0.26 0.33 0.26 0.13 0.185 0.24 0.30 0.15 0.21 0.26 0.28 0.22 0.19 0.25 Luminous flux at 25°C [lm] 1200 1900 2600 3320 2800 1150 1800 2450 3100 1500 2055 2470 2x 1200 2x 1900 2x 2600 2x 3320 2x 2800 2x 1150 2x 1800 2x 2450 2x 3100 2x 1500 2x 2055 2x 2470 3x 1200 4x 1200 3x 1150 4x 1100 Luminous flux at 35°C [lm] 1350 2100 2900 3650 1350 2100 2900 3650 1600 2200 2600 2x 1350 2x 2100 2x 2900 2x 3650 2x 1350 2x 2100 2x 2900 2x 3650 2x 1600 2x 2200 2x 2600 3x 1350 4x 1350 3x 1350 3x 1290 Power factor [λ] 0.90c 0.95 0.96 0.97 0.95 0.90c 0.95 0.96 0.97 0.92 0.95 0.95 0.98 0.98 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.95 0.96 0.95 0.95 0.97 0.95 0.97 GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 06 QUICKTRONIC PROFESSIONAL QTP5 ECG QTP5 1x24-39 QTP5 2x24-39 QTP5 1x49 QTP5 2x49 QTP5 1x54 QTP5 2x54 QTP5 1x80 Lamp HO 24 HO 39 L 30 HO 20 ES6 HO 34 ES6 T8 L 36 W6 2x HO 24 2x HO 39 2x L 30 6 2x HO 20 ES 6 2x HO 34 ES 2x T8 L 36 W6 HO 49 HO 45 ES6 2x HO 49 2x HO 45 ES6 HO 54 HO 50 ES6 T8 L 586 DL 556 2x HO 54 2x HO 50 ES6 2x T8 L 586 2x DL 556 HO 80 DL 80 HO 73 ES6 HF lamp wattage [W] 23 38 30 20 34 32 2x 22.5 2x 38 2x 28.5 2x 21 2x 35 64 49 45 2x 49.5 92 54 50 50 50 2x 54 100 100 102 80 80 73 System wattage [W] 26 41 33 23 37 36 49 82 62 45 75 70 53 49 106 100 59 54 55 54 115 108 109 110 86 86 79 Line current [A] 0.12 0.18 0.15 0.105 0.165 0.16 0.23 0.36 0.27 0.195 0.32 0.31 0.24 0.22 0.49 0.44 0.26 0.24 0.25 0.24 0.50 0.46 0.48 0.48 0.38 0.38 0.35 Luminous flux at 25°C [lm] 1750 3100 3000 1650 3250 3200 2x 1750 2x 3100 2x 2850 2x1650 2x3250 2x 3200 4310 4310 2x 4310 2x 4310 4450 4450 5000 4450 2x 4450 2x 4450 2x 5000 2x 4500 6150 6000 6150 Luminous flux at 35°C [lm] 2000 3500 2000 3500 2x 2000 2x 3500 2x2000 2x3500 4900 4900 2x 4900 2x 4900 5000 5000 2x 5000 2x 5000 7000 7000 Power factor [λ] 0.95 0.98 0.97 0.95 0.98 0.97 0.95 0.98 0.98 0.95 0.98 0.98 0.95 0.95 0.97 0.99 0.98 0.98 0.97 0.98 0.99 0.99 0.97 0.99 0.98 0.99 0.98 For more information on ECG refer to http://www.osram.com/ecg For more information on System Guarantee refer to http://www.osram.com/guarantee 6 Additional Lamp-ballast combination without ENEC GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 07