M-FIAM3 Data Sheet

Military COTS 270 Vin Filter
M-FIAM3
Model Number M-FIAM3M21*
Input Attenuator Module
Features
•
•
•
•
•
•
•
•
EMI filtering-MIL-STD-461E[1]
Transient protection-MIL-STD-704E/F
Environments-MIL-STD-810, MIL-STD-202
Environmental stress screening
Low profile mounting options
Output current up to 3 A
Mini sized package
Inrush current limiting
Actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Absolute Maximum Rating
Parameter
+In to –In
Product Highlights
The M-FIAM3 is a DC front-end module
that provides EMI filtering and transient
protection. The M-FIAM3 enables designers
using Vicor’s Maxi, Mini, Micro Series 300 V
DC-DC converters to meet conducted
emission/ conducted susceptibility per
MIL-STD-461E; and input transients per
MIL-STD-704E/F. The M-FIAM3 accepts an
input voltage of 180 – 375 Vdc and delivers
output current up to 3 A.
M-FIAM3 is housed in an industry
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted on-board
or in-board for height critical applications.
Mounting torque
Pin Soldering temperature
Rating
375
Unit
Vdc
Notes
Continuous
400
Vdc
100 ms
5 (0.57)
in-lbs
6 each, #4-40 or M3
500 (260)
°F (°C)
<5 sec; wave solder
750 (390)
°F (°C)
<7 sec; hand solder
Thermal Resistance and Capacity
Parameter
Min
Baseplate to sink
flat, greased surface
with thermal pad (P/N 20264)
Baseplate to ambient
Free convection
1000 LFM
Typ
Max
Unit
0.16
0.1
°C/Watt
°C/Watt
7.9
2.2
°C/Watt
°C/Watt
MTBF per MIL-HDBK-217F (M-FIAM3M21)
Compatible Products
Temperature
Environment
MTBF
Unit
• Maxi, Mini, Micro Series 300 V Input
DC-DC converters
25°C
Ground Benign: G.B.
13,291
1,000 Hrs
50°C
Naval Sheltered: N.S.
2,392
1,000 Hrs
65°C
Airborne Inhabited Cargo: A.I.C.
1,874
1,000 Hrs
[1]
EMI performance is subject to a wide
variety of external influences such as PCB
construction, circuit layout etc. External
components in addition to those listed herein
may be required in specific instances to gain
full compliance to the standards specified at
various line and load conditions.
Part Numbering
M-FIAM3
Product
[2]
[3]
M
Product Grade Temperatures
(°C)
Grade Operating
Storage
H = –40 to +100 – 55 to +125
M = –55 to +100 – 65 to +125
Compatible with SurfMate and InMate socketing system
Not intended for socket or Surfmate mounting
M-FIAM 3
Rev 2.9
vicorpower.com
Page 1 of 6
12/2014
800 927.9474
2
1 =
2 =
S=
N=
F =
G=
K=
Pin Style
Short Pin
Long Pin
[2]
Short ModuMate [2]
Long ModuMate
Short RoHS
Long RoHS
[3]
Extra Long RoHS
1
Baseplate
1 = Slotted
2 = Threaded
3 = Thru hole
M-FIAM3M21
SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Input voltage
180
270
375
Vdc
Continuous
0.018
A/µF
Inrush limiting
Transient immunity
Exceeds limits of MIL-STD-704E/F
OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
3
A
Output current
Efficiency
Internal voltage drop
96
98
3.0
Notes
%
5.0
@3 A, 100°C baseplate
External capacitance
10
See Figure 5 on page 4.
400 V
22
µF
Max
Unit
Notes
CONTROL PIN SPECIFICATIONS
Parameter
Min
ON/OFF control
Enable (ON)
0.0
1.0
Vdc
Referenced to – Vout
3.5
5.0
Vdc
100 kΩ internal pull-up resistor
Typ
Max
Unit
Notes
1,500
Vrms
Input/Output to Base
2,121
Vdc
Input/Output to Base
Disable (OFF)
Typ
SAFETY SPECIFICATIONS
Parameter
Dielectric withstand
Min
EMI
Standard
MIL-STD-461E
Conducted emissions:
Conducted susceptibility:
Test Procedure
Notes
CE101, CE102
CS101, CS114, CS115, CS116
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components
in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified.
M-FIAM 3
Rev 2.9
vicorpower.com
Page 2 of 6
12/2014
800 927.9474
M-FIAM3M21
SPECIFICATIONS (CONT.)
GENERAL SPECIFICATIONS
Parameter
Min
Weight
Typ
Max
3.3 (94)
Warranty
Unit
Notes
Ounces (grams)
2
Years
ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9 ms half sine. MIL-STD-202F, Method 213B, 75 g, 11 ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
ENVIRONMENTAL STRESS SCREENING
Parameter
H-Grade
M-Grade
Operating temperature
-40°C to +100°C
-55°C to +100°C
Storage temperature
-55°C to +125°C
-65°C to +125°C
Temperature cycling*
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
Ambient test @ 25°C
Yes
Yes
Power cycling burn-in
12 hours, 29 cycles
24 hours, 58 cycles
Functional and parametric ATE tests
-40°C and +100°C
-55°C and +100°C
Hi-Pot test
Yes
Yes
Visual inspection
Yes
Yes
vicorpower.com
vicorpower.com
Test data
*Temperature cycled with power off, 17°C per minute rate of change.
M-FIAM 3
Rev 2.9
vicorpower.com
Page 3 of 6
12/2014
800 927.9474
M-FIAM3M21
Output
Input
Figure 1 – Conducted noise; M-FIAM3 and V300A48C500BG
DC-DC converter operating at 270 Vdc input at 450 W.
Figure 2 – Transient Immunity; M-FIAM3 output response to
an input transient.
M-FIAM3 Diff. & Comm. Mode Insertion Loss
10.000
0.000
IL [dB]
-10.000
-20.000
-30.000
-40.000
-50.000
-60.000
-70.000
0.01
0.1
1
10
Frequency [MHz]
Note: The M-FIAM3 is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
F1
Input
+OUT
NC
NC
MOV P/N
30076
M-FIAM3
EMI
GND
–IN
NC
Comm. Mode IL
Figure 4– Insertion Loss Curve
Figure 3– Inrush Limiting; Inrush current with 22 μF external
capacitance, (C1 in Figure 5)
+IN
Diff. Mode IL
4700 pF
Y2 type
0.01 µF
+OUT
+IN
PC
C1
0.3µF
ON
OFF
PR
–OUT
–IN
Maxi, Mini, Micro
300 Vdc Input
DC-DC Converter
+S
SC
–S
–OUT
4700 pF
Y2 type
Component Suggestions
Recommended Fuse: (F1) 3 A Max., Bussmann ABC style
Capacitance: (C1)10 µF(min), 22 µF(max)
Figure 5 – Basic connection diagram with Transient, Surge Protection and Recommended Reverse Polarity Protection.
M-FIAM 3
Rev 2.9
vicorpower.com
Page 4 of 6
12/2014
800 927.9474
0.01 µF
M-FIAM3M21
MECHANICAL DRAWINGS
Module Pins
No.
Function
Label
1
+In
+
2
No
Connection
NC
3
Ground
EMI/GND
4
– In
–
5
– Out
–
6
ON/OFF
ON/OFF
7
No
Connection
NC
8
No
Connection
NC
9
+Out
+
DIMENSION L
PIN SHORT – .54 [13.7]
PIN LONG–– .62 [15.7]
PIN EXTRA LONG–––- .71 [18.0]
NOTES:
1. MATERIAL:
BASE:
6000 SERIES ALUMINUM
COVER: LCP, ALUMINUM 3003 H14
PINS:
RoHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS
PINS:
TIN/LEAD 90/10 BRIGHT
2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC
3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD
OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION
Figure 6 – Mechanical diagram
PCB THICKNESS
R
0.062 ±0.010
1,57 ±0,25
PLATED
THROUGH HOLE
DIA
1.790**
45,47
0.06
(4X)
1,5
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
SHORT PIN STYLE
LONG PIN STYLE
(7X)
0.094 ±0.003
2,39 ±0,08
0.094 ±0.003
2,39 ±0,08
(2X)
0.164 ±0.003
4,16 ±0,08
0.164 ±0.003
4,16 ±0,08
THIS SURFACE
0.158
4,01
1
2
3
4
ALUMINUM
BASEPLATE
1.575**
40,00
1.900*
48.26
48,26
9
8
7
6
PINS STYLES
SOLDER:TIN / LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
5
0.400*
10,16
0.43
0.45
0.45
11,5
0.700*
17,78
0.195
4,95
1.000*
25,40
1.400*
35,56
* DENOTES TOL =
0.53
13,5
±0.003
±0,08
** PCB WINDOW
Figure 7 – PCB Mounting Specifications
M-FIAM 3
Rev 2.9
vicorpower.com
Page 5 of 6
12/2014
800 927.9474
M-FIAM3M21
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
M-FIAM 3
Rev 2.9
vicorpower.com
Page 6 of 6
12/2014
800 927.9474