MIL-COTS Filter MF028AMFPT S ® C US C NRTL US DC front-end module with EMI filtering & transient protection Features • –55°C to 100°C baseplate operation • Height above board: 0.37 in (9.5 mm) • Vin range: 16.5 – 50 Vdc • Low weight: 1.07 oz (30.4g) • EMI filtering: MIL-STD-461E/F • Typical efficiency: 99% • Transient protection MIL-STD-1275 • Architectural flexibility A/B/D and MIL-STD-704A/E/F Size: 1.91 x 1.09 x 0.37 in 48,6 x 27,7 x 9,5 mm Product Overview The MIL-COTS filter is a DC front-end module that provides EMI filtering and transient protection. The filter enables designers using Vicor’s MIL-COTS PRM®, VI Bricks™ and VI Chips® to meet conducted emission / conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704A/E/F and MIL-STD-1275A/B/D. The MIL-COTS PRM filter accepts an input voltage of 16.5 –50 Vdc and delivers output power up to 120 W. Absolute Maximum Ratings Parameter +In to -In +Out to -Out Continuous output power Operating temperature Storage temperature Values Unit Notes -1.0 to 60.0 -1.0 to 60.0 120 -55 to +100 -65 to +125 Vdc Vdc W °C °C Continuous Continuous M-Grade; baseplate M-Grade Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability. MIL-COTS Filter Rev 1.6 vicorpower.com Page 1 of 6 06/2014 800 927.9474 MF028AMFPT SPECIFICATIONS PART NUMBERING MF 028 A M VI BRICK Filter Input Voltage Designator Package Size F Product Grade Temperatures (°C) Grade M= Input Specifications Operating -55 to +100 Storage -65 to +125 P Baseplate F = Slotted flange P = Pin Fin heat sink[a] [a] Contact Factory Pin Style P = Through hole (Conditions are at 28 Vin, full load, and 25°C baseplate unless otherwise specified) Parameter Min Typ Max Unit Notes Input voltage range Input current Inrush limiting Recommended external input capacitance Transient Immunity 16.5 28 50 8 0.01 Vdc Adc A/µF µF Vdc Vdc Vdc Vdc Vdc Operation to 13.5 V after start up ≥ 16.5 V Output Specifications 10 100 250 70 80 50 C1 Figure 7 50 ms per MIL-STD-1275A/B/D continuous operation 70 µs per MIL-STD-1275A/B/D continuous operation 20 ms per MIL-STD-704A continuous operation 100 ms per D0-160 E, sec.16, Cat. z cont. operation 12.5 ms per MIL-STD-704E/F continuous operation (Conditions are at 28 Vin, full load, and 25°C baseplate unless otherwise specified) Parameter Min Typ Max Unit Note Output voltage range Internal voltage drop Output current Efficiency Full load External output capacitance 16.0 28 0.4 49.6 0.85 8 Vdc Vdc Adc Over input range 0 99 1000 % µF Figure 7 CIN Safety Specifications Parameter Min Typ Dielectric withstand Max Unit Note None 707 Vrms Vdc Input / Output Input / Output to Base / EMI Pin EMI Standard T Test Procedure Notes MIL-STD-461E/F Conducted Emissions CE101-4 Navy ASW & Army Aircraft, Curve #2 (28 Vdc) CE102-1 Basic curve, for all applications Conducted Susceptability CS101-1 Curve #2, for all applications (28 Vdc) CS114-1 Conducted suceptibility, bulk cable injection, 10 KHz - 200 MHz, Curve #4 CS115-1 Conducted suceptibility, bulk cable injection, impulse excition, all applications MIL-COTS Filter Rev 1.6 vicorpower.com Page 2 of 6 06/2014 800 927.9474 MF028AMFPT SPECIFICATIONS (CONT.) General Specifications Parameter Min MTBF MIL-HDBK-217F Typ Max 12,933,333 2,327,752 1,823,912 Agency approvals Unit hrs hrs hrs CE Mark Mechanical parameters Weight Dimensions Length Width Height Thermal Thermal capacity Baseplate to ambient Baseplate to ambient; 1000 LFM Baseplate to sink; flat, greased surface Baseplate to sink; thermal pad 1.07/30,4 oz/g 1.91/46,6 in/mm in/mm in/mm 1.09/27,7 0.37/9,5 23.8 Notes 25°C, GB 50°C, NS 65°C, AIC Low voltage directive (10 A external fuse required), EN60950-1 See Mechanical Drawings, Figures 2 & 4 Ws/°C °C/W °C/W °C/W °C/W 8.8 3.0 0.40 0.36 ON/OFF EMI GRD –OUT +OUT –IN +IN Figure 1 — Conducted Noise (CE 102); MF028AMFPT with PRM and VTM, Figure 2 — MF028AMFPT pin configuration (viewed from pin side) 28 Vdc input, 12 Vdc output, 90% load. 40 20 Gain [dB] 0 -20 CM Attenuation DM Attenuation -40 -60 -80 -100 0.01 0.1 1 10 Frequency [MHz] Figure 3 — MF028AMFPT insertion loss MIL-COTS Filter Rev 1.6 vicorpower.com Page 3 of 6 06/2014 800 927.9474 MF028AMFPT SPECIFICATIONS (CONT.) Part Description Value C1 CIN Recommended input capacitor Recommended external capacitor 10 µF / 100 V Input Voltage 100 Vdc +IN + VIN C1 –IN – +OUT VOUT –OUT EMI GRD Output Voltage clamped to 50 Vdc + CIN – ON/OFF NOTE: The module is enabled when ON/OFF pin is connected to -OUT. The module is disabled when ON/OFF pin is open circuit (floating). Figure 4 — Connection for filter enabled at turn on Figure 5 — Transient immunity; MF028AMFPT output response to an input transient. (28 VIN full load initial conditions, trace 1.5 A/div) Shut Down Time vs. Overvoltage 400 350 T (ms) 300 250 200 150 100 50 0 107 100 90 80 Vin 70 60 (V) Figure 6 — Shutdown time vs. overvoltage MF028AMFPT VIN VC PC TM IL NC PR +IN + C1 – –IN +OUT +In CIN –OUT EMI GRD +Out Y-Cap 0.033µF Y-Cap 0.033µF ON/OFF PRM VH SC SG OS NC CD –In –Out Figure 7 — Recommended circuit for EMI MIL-COTS Filter Rev 1.6 vicorpower.com Page 4 of 6 06/2014 800 927.9474 +Out +In TM VC PC Y-Cap 0.033µF VTM -Out +Out VOUT -In -Out Y-Cap 0.033µF MF028AMFPT MECHANICAL DRAWINGS Baseplate - Slotted Flange Figure 8 — Module outline Recommended PCB Pattern (Component side shown) Note: Figure 9 — PCB mounting specifications MIL-COTS Filter Rev 1.6 vicorpower.com Page 5 of 6 06/2014 800 927.9474 MF028AMFPT Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department. The products described on this data sheet are protected by the following U.S. Patents Numbers: 5,945,130; 6,403,009; 6,710,257; 6,788,033; 6,940,013; 6,969,909; 7,038,917; 7,154,250; 7,166,898; 7,187,263; 7,202,646; 7,361,844; 7,368,957; RE40,072; D496,906; D506,438; D509,472; and for use under U.S. Pat. Nos. 6,975,098 and 6,984,965. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] MIL-COTS Filter Rev 1.6 vicorpower.com Page 6 of 6 06/2014 800 927.9474