MIL-COTS Filter

MIL-COTS Filter
MF028AMFPT
S
®
C
US
C
NRTL
US
DC front-end module with EMI filtering & transient protection
Features
• –55°C to 100°C baseplate operation
• Height above board: 0.37 in (9.5 mm)
• Vin range: 16.5 – 50 Vdc
• Low weight: 1.07 oz (30.4g)
• EMI filtering: MIL-STD-461E/F
• Typical efficiency: 99%
• Transient protection MIL-STD-1275
• Architectural flexibility
A/B/D and MIL-STD-704A/E/F
Size:
1.91 x 1.09 x 0.37 in
48,6 x 27,7 x 9,5 mm
Product Overview
The MIL-COTS filter is a DC front-end module that provides EMI filtering and transient protection. The filter enables designers using Vicor’s MIL-COTS
PRM®, VI Bricks™ and VI Chips® to meet conducted emission / conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704A/E/F
and MIL-STD-1275A/B/D. The MIL-COTS PRM filter accepts an input voltage of 16.5 –50 Vdc and delivers output power up to 120 W.
Absolute Maximum Ratings
Parameter
+In to -In
+Out to -Out
Continuous output power
Operating temperature
Storage temperature
Values
Unit
Notes
-1.0 to 60.0
-1.0 to 60.0
120
-55 to +100
-65 to +125
Vdc
Vdc
W
°C
°C
Continuous
Continuous
M-Grade; baseplate
M-Grade
Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions
in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
MIL-COTS Filter
Rev 1.6
vicorpower.com
Page 1 of 6
06/2014
800 927.9474
MF028AMFPT
SPECIFICATIONS
PART NUMBERING
MF
028
A
M
VI BRICK Filter
Input
Voltage
Designator
Package
Size
F
Product Grade Temperatures (°C)
Grade
M=
Input Specifications
Operating
-55 to +100
Storage
-65 to +125
P
Baseplate
F = Slotted flange
P = Pin Fin heat sink[a]
[a] Contact Factory
Pin Style
P = Through hole
(Conditions are at 28 Vin, full load, and 25°C baseplate unless otherwise specified)
Parameter
Min
Typ
Max
Unit
Notes
Input voltage range
Input current
Inrush limiting
Recommended external input capacitance
Transient Immunity
16.5
28
50
8
0.01
Vdc
Adc
A/µF
µF
Vdc
Vdc
Vdc
Vdc
Vdc
Operation to 13.5 V after start up ≥ 16.5 V
Output Specifications
10
100
250
70
80
50
C1 Figure 7
50 ms per MIL-STD-1275A/B/D continuous operation
70 µs per MIL-STD-1275A/B/D continuous operation
20 ms per MIL-STD-704A continuous operation
100 ms per D0-160 E, sec.16, Cat. z cont. operation
12.5 ms per MIL-STD-704E/F continuous operation
(Conditions are at 28 Vin, full load, and 25°C baseplate unless otherwise specified)
Parameter
Min
Typ
Max
Unit
Note
Output voltage range
Internal voltage drop
Output current
Efficiency
Full load
External output capacitance
16.0
28
0.4
49.6
0.85
8
Vdc
Vdc
Adc
Over input range
0
99
1000
%
µF
Figure 7 CIN
Safety Specifications
Parameter
Min
Typ
Dielectric withstand
Max
Unit
Note
None
707
Vrms
Vdc
Input / Output
Input / Output to Base / EMI Pin
EMI
Standard
T
Test Procedure
Notes
MIL-STD-461E/F
Conducted Emissions
CE101-4
Navy ASW & Army Aircraft, Curve #2 (28 Vdc)
CE102-1
Basic curve, for all applications
Conducted Susceptability
CS101-1
Curve #2, for all applications (28 Vdc)
CS114-1
Conducted suceptibility, bulk cable injection,
10 KHz - 200 MHz, Curve #4
CS115-1
Conducted suceptibility, bulk cable injection, impulse
excition, all applications
MIL-COTS Filter
Rev 1.6
vicorpower.com
Page 2 of 6
06/2014
800 927.9474
MF028AMFPT
SPECIFICATIONS (CONT.)
General Specifications
Parameter
Min
MTBF
MIL-HDBK-217F
Typ
Max
12,933,333
2,327,752
1,823,912
Agency approvals
Unit
hrs
hrs
hrs
CE Mark
Mechanical parameters
Weight
Dimensions
Length
Width
Height
Thermal
Thermal capacity
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad
1.07/30,4
oz/g
1.91/46,6
in/mm
in/mm
in/mm
1.09/27,7
0.37/9,5
23.8
Notes
25°C, GB
50°C, NS
65°C, AIC
Low voltage directive (10 A external fuse
required), EN60950-1
See Mechanical Drawings, Figures 2 & 4
Ws/°C
°C/W
°C/W
°C/W
°C/W
8.8
3.0
0.40
0.36
ON/OFF
EMI
GRD
–OUT
+OUT
–IN
+IN
Figure 1 — Conducted Noise (CE 102); MF028AMFPT with PRM and VTM,
Figure 2 — MF028AMFPT pin configuration (viewed from pin side)
28 Vdc input, 12 Vdc output, 90% load.
40
20
Gain [dB]
0
-20
CM Attenuation
DM Attenuation
-40
-60
-80
-100
0.01
0.1
1
10
Frequency [MHz]
Figure 3 — MF028AMFPT insertion loss
MIL-COTS Filter
Rev 1.6
vicorpower.com
Page 3 of 6
06/2014
800 927.9474
MF028AMFPT
SPECIFICATIONS (CONT.)
Part
Description
Value
C1
CIN
Recommended input capacitor
Recommended external capacitor
10 µF / 100 V
Input Voltage
100 Vdc
+IN
+
VIN
C1
–IN
–
+OUT
VOUT
–OUT
EMI
GRD
Output Voltage
clamped to 50 Vdc
+
CIN
–
ON/OFF
NOTE: The module is enabled when ON/OFF pin is connected to -OUT.
The module is disabled when ON/OFF pin is open circuit (floating).
Figure 4 — Connection for filter enabled at turn on
Figure 5 — Transient immunity; MF028AMFPT output response to an
input transient. (28 VIN full load initial conditions, trace 1.5 A/div)
Shut Down Time vs. Overvoltage
400
350
T (ms)
300
250
200
150
100
50
0
107
100
90
80
Vin
70
60
(V)
Figure 6 — Shutdown time vs. overvoltage
MF028AMFPT
VIN
VC
PC
TM
IL
NC
PR
+IN
+
C1
–
–IN
+OUT
+In
CIN
–OUT
EMI
GRD
+Out
Y-Cap
0.033µF
Y-Cap
0.033µF
ON/OFF
PRM
VH
SC
SG
OS
NC
CD
–In
–Out
Figure 7 — Recommended circuit for EMI
MIL-COTS Filter
Rev 1.6
vicorpower.com
Page 4 of 6
06/2014
800 927.9474
+Out
+In
TM
VC
PC
Y-Cap
0.033µF
VTM
-Out
+Out
VOUT
-In
-Out
Y-Cap
0.033µF
MF028AMFPT
MECHANICAL DRAWINGS
Baseplate - Slotted Flange
Figure 8 — Module outline
Recommended PCB Pattern
(Component side shown)
Note:
Figure 9 — PCB mounting specifications
MIL-COTS Filter
Rev 1.6
vicorpower.com
Page 5 of 6
06/2014
800 927.9474
MF028AMFPT
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
The products described on this data sheet are protected by the following U.S. Patents Numbers:
5,945,130; 6,403,009; 6,710,257; 6,788,033; 6,940,013; 6,969,909; 7,038,917; 7,154,250; 7,166,898; 7,187,263; 7,202,646; 7,361,844;
7,368,957; RE40,072; D496,906; D506,438; D509,472; and for use under U.S. Pat. Nos. 6,975,098 and 6,984,965.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
MIL-COTS Filter
Rev 1.6
vicorpower.com
Page 6 of 6
06/2014
800 927.9474