CLAMP ON PROBE 9010-50 < Clamp Sensors < Products Clamp Sensors (For power line current measurement 50/60 Hz use-) CLAMP ON PROBE 9010-50 CAT III 600 V OVERVIEW OPTION Easy-to-use, current to voltage transformer ● ● ● Choose from up to six general-purpose ranges Combine use of the dedicated ranges with HIOKI Digital HiTESTERs to measure live conductors Connect with optional BNC-Banana Adapter for greater flexibility Basic specifications Rated current 6 selectable ranges - 10/20/50/100/200/500A AC Frequency band width 40 to 1 kHz (±6 % rdg max. for 10A and 20A ranges, ±3 % rdg max. for ranges 50A and above) Accuracy (at 50 or 60 Hz) ±2% rdg. ±1%f.s. (45 to 66Hz) Output rate 0.2 V AC at full scale range (AC voltage output), Connect to a voltage input device providing a high input impedance of 1Mohm, etc. Output terminal: Insulated BNC Max. current input 150A rms (10/20/50A range) 400A rms (100/200A range) 650A rms (500A range) Max. rated voltage to earth 600 V AC rms (insulated conductor) Core jaw diameter Ø46 mm(1.81 in) Power supply None Dimensions, mass 74 mm(2.91 in)W × 190 mm (7.48 in)H × 35 mm(1.38 in)D, 420 g (14.8 oz), cord length: 3 m(9.84 ft) Accessories None OVERVIEW OPTION Generated by www.PDFonFly.com