PD050VL1 - AZ Displays, Inc.

PD050VL1
Version :4.0
TECHNICAL
MODEL
SPECIFICATION
NO : PD050VL1
The content of this information is subject to be changed without notice.
Please contact PVI or its agent for further information.
Customer’s Confirmation
Customer
Date
By
PVI’s Confirmation
FOR MORE INFORMATION:
AZ DISPLAYS, INC.
75 COLUMBIA, ALISO VIEJO, CA 92656
Http://www.AZDISPLAYS.com
Confirmed By
Prepared By
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:1
PD050VL1
Revision History
Rev.
1.0
Issued Date
May 7, 2007
2.0
Mar 12, 2008
3.0
4.0
Revised
New
Delete Page4
2. Features: Image Reversion : Up/Down and Left/Right
Add
March.24.2008 Page 19 14.Handling Cautions
14-1 item e)
Aug. 18,2009 Modified Page 22 16.Packing Diagram
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:2
PD050VL1
TECHNICAL
SPECIFICATION
CONTENTS
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ITEM
Cover
Revision History
Contents
Application
Features
Mechanical Specifications
Mechanical Drawing of TFT-LCD module
Input Terminals
Absolute Maximum Ratings
Electrical Characteristics
Pixel Arrangement
Display Color and Gray Scale Reference
Block Diagram
Interface Timing
Power On Sequence
Optical Characteristics
Handling Cautions
Reliability Test
Packing Diagram
PAGE
1
2
3
4
4
4
5
7
9
9
10
11
12
13
16
16
19
21
22
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:3
PD050VL1
1. Application
PD050VL1 module applies to computer peripheral, industrial meter, car TV, image
communication and multi-media, which requires high quality flat panel display. If you must use in
severe reliability environment, please don’t extend over PVI’s reliability test conditions.
2. Features.
. Support the DENB mode, Sync mode (Hsync+Vsync)
. Pixel in stripe configuration
. Slim and compact
. Amorphous silicon TFT LCD panel with LED B/L
. LVDS transmission interface
3. Mechanical Specifications
Parameter
Screen Size
Display Format
Display Colors
Active Area
Pixel Pitch
Pixel Configuration
Outline Dimension
Back-light
Weight
Surface treatment
Display mode
Gray scale inversion direction
Specifications
5(diagonal)
640ͪ(R,G,B )ͪ480
262K
101.76 (H)ͪ74.88(V)
0.159(H)ͪ0.156(V)
Stripe
120.7(H)ͪ92.8(V)Ø12.5(D) (Typ.)
24-LED
173.6+10
Anti-glare and SWV film
Normally white
6
(ref to Note 13-1 )
Unit
inch
dot
mm
mm
mm
g
o’clock
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:4
PD050VL1
4.Mechanical Drawing of TFT-LCD Module
Outline Drawing : Front View (unit mm)
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:5
PD050VL1
ʳ
Outline Drawing : Rear View (unit mm)
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:6
PD050VL1
5.Input Terminals
5-1) TFT-LCD Panel Driving
Connector type: DFL19K-20P-1H(HRS)
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Symbol
Vcc
Vcc
GND
GND
INOINO+
GND
IN1IN1+
GND
IN2IN2+
GND
CLKCLK+
GND
NC
NC
GND
GND
Function
+3.3V Power Supply
+3.3V Power Supply
Ground
Ground
LVDS receiver signal channel 0
LVDS receiver signal channel 0
Ground
LVDS receiver signal channel 1
LVDS receiver signal channel 1
Ground
LVDS receiver signal channel 2
LVDS receiver signal channel 2
Ground
LVDS receiver signal clock
LVDS receiver signal clock
Ground
No connection
No connection
Ground
Ground
Remark
LVDS Interface Block Diagram
B0~B5
TIN12~TIN17
Hsync
TIN18
Vsync
TIN19
DENB
TIN20
CLK IN
TCLK IN
IN0+
IN1IN1+
IN2IN2+
CLK -
PLL
THC63LVDM 63A
Customer system side
IN0-
CLK +
PLL
RxOUT0~RxOUT5
RxOUT6~RxOUT11
RxOUT12~RxOUT17
RxOUT18
RxOUT19
RxOUT20
LCD Internal Circuit
TIN6~TIN11
LVDS to TTL parallel
G0~G5
TIN0~TIN5
TTL parallel to LVDS
Graphic Controller Circuit
R0~R5
CLK OUT
THC63LVDF64A
PD050VL1 m odule side
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:7
PD050VL1
Recommended Transmitter (THC63LVDM63A Thane) to PD050VL1 interface Assignment:
Input terminal of
THC63LVDM63A
Graphic controller output signal
Symbol
TIN0
TIN1
TIN2
TIN3
TIN4
TIN5
TIN6
TIN7
TIN8
TIN9
TIN10
TIN11
TIN12
TIN13
TIN14
TIN15
TIN16
TIN17
TIN18
TIN19
TIN20
No.
44
45
47
48
1
3
4
6
7
9
10
12
13
15
16
18
19
20
22
23
25
Symbol
R0
R1
R2
R3
R4
R5
G0
G1
G2
G3
G4
G5
B0
B1
B2
B3
B4
B5
Hsync
Vsync
DENB
CLK in
26
CLK
To PD050VL1
Output signal
interface terminal
symbol
(Symbol)
Function
Red pixel data (LSB)
Red pixel data
Red pixel data
Red pixel data
Red pixel data
Red pixel data(MSB)
Green pixel data (LSB)
Green pixel data
Green pixel data
Green pixel data
Green pixel data
Green pixel data(MSB)
Blue pixel data(LSB)
Blue pixel data
Blue pixel data
Blue pixel data
Blue pixel data
Blue pixel data(MSB)
Horizontal Synchronous Signal
Vertical Synchronous Signal
Compound Synchronization signal
Data sampling clock
Tout0-
No.5 : IN0-
Tout0+
No.6 : IN0+
Tout1-
No.8 : IN1-
Tout1+
No.9 : IN1+
Tout2-
No.11 : IN2-
Tout2+
N0.12 : IN2+
TCLK outTCLK out+
No.14 : CLKЁ
No.15 : CLKЀ
DENB input signal.
If customer wanted to off the DENB mode , you must keep the DENB always
High or Low.
ˋ˃˃ʳ̇˶
ˉˇ˃ʳ̇˶
˗˘ˡ˕
(tc: the period of sampling clock)
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:8
PD050VL1
5-2) Backlight driving
Connector type: JST BHSR-02VS-1, PIN No 2 pin
Pin No
1
2
Symbol
+
-
Description
Input terminal (Positive electrode side)
Input terminal (Ground side)
Remark
Wire color : Red
Wire Color : Black
6. Absolute Maximum Ratings :
The followings are maximum values, which if exceeded, may cause faulty operation or
damage to the unit.
GND=0V, Ta=25ʚ
Parameters
Symbol
MIN.
MAX.
Unit
Remark
Supply Voltage
VCC
-0.3
+7.0
V
Input Signals Voltage
Vsig
-0.3
VCC+0.3
V
Note 6-1
Note 6-1 : Input signals include CLK , Hsync , Vsync , DENB , R[0:5] , G[0:5] and B[0:5].
7.Electrical Characteristics
7-1) Recommended Operating Conditions:
Item
Symbol
Supply Voltage
Vcc
Current Dissipation
Icc
LVDS Differential input high threshold
VTH
LVDS Differential input low threshold
VTL
Vcom Voltage
Vcom
Min.
3.0
-100
-
Typ.
3.3
77.90
2.7
GND = 0VΔTa = 25к
Max.
Unit
Remark
3.6
V
mA
Note 7-1
100
mV
Note7-2
V
Note 7-1 : To test the current dissipation of VCC using the “color bars” testing pattern shown as
below
1
2
3
4
5
6
7
8
1.
2.
3.
4.
5.
6.
7.
8.
White
Yellow
Cyan
Green
Magenta
Red
Blue
Black
Idd current dissipation testing pattern
Note7-2 : Please refers to THC63LVDF64A specification by THINE Corporation.
This LCD module conforms to LVDS standard.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:9
PD050VL1
7-2) Recommended driving condition for LED backlight
GND = 0VΔTa = 25к
Parameter
Symbol
Min
TYP MAX Unit
Remark
Supply voltage of LED backlight
VLED
11.0
11.5
V
IL = 20 mA
Supply current of LED backlight
ILED
20
mA
Note 7-3
Backlight Power Consumption
PLED
1.76
1.84
W
Note 7-4
Note 7-3: The LED driving condition is defined for each LED module. (3 LED Serial)
Note 7-4: PLED = VLED1 * ILED1 + VLED2 * ILED2…. + VLED7 * ILED7+VLED8 * ILED8
Anode
Cathode
8. Pixel Arrangement
The LCD module pixel arrangement is the stripe.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:10
PD050VL1
9. Display Color and Gray Scale Reference
Color
Input Color Data
Green
Red
Blue
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Basic
Colors
Red
Green
Blue
Black
Red (63)
Green (63)
Blue (63)
Cyan
Magenta
Yellow
White
Red (00)
Red (01)
Red (02)
Darker
ʆ
Brighter
Red (61)
Red (62)
Red (63)
Green (00)
Green (01)
Green (02)
Darker
ʆ
Brighter
Green (61)
Green (62)
Green (63)
Blue (00)
Blue (01)
Blue (02)
Darker
ʆ
Brighter
Blue (61)
Blue (62)
Blue (63)
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ
1
1
1
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
0
1
1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
0
1
1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ ʆ
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
0
1
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:11
PD050VL1
10. Block Diagram
10-1) TFT-module Block Diagram
˦ˬ˦˧˘ˠ
ʾˆˁˆ˩
˨̆˸̅
̆˼˺́˴˿ʳ
˼́̃̈̇
˧˼̀˼́˺ʳ˖̂́̇̅̂˿˿˸̅
THC63LVDF64A
ʻˣ˩˜ˀ˅˃˃ˆ˔ʼ
˩˼˷˸̂
˖̂́̇̅̂˿
˩˗˗˄
˗˖ˀ˗˖ʳ
˖̂́̉˸̅̇˸̅
˚˴̀̀˴
˚˸́˸̅˴̇̂̅
˩˶̂̀
˚˸́˸̅˴̇̂̅
˩˚˚ʳ˂ʳ˩˘˘
˩˗˗˅
˚˴̀̀˴
˙ˣ˖
˦̂̈̅˶˸
˗̅˼̉˸̅
˜˖
ˈʵ˩˚˔
˧˙˧ˀ˟˖˗ʳˣ˴́˸˿
˩˶̂̀
˚˴̇˸ʳ˗̅˼̉˸̅ʳ˜˖
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:12
PD050VL1
11. Interface Timing
11-1) Timing Parameters
Power supply
CLK
Frequency
Period
Display period
Pulse width
HSYNC Back-porch
Front-porch
Hpw+Hbp
Hsync-CLK
Vsync-Hsync
Period
Display period
VSYNC Pulse width
Back-porch
Front-porch
Vpw+Vbp
Horizontal
scanning period
Horizontal display
period
DENB
Vertical display
period
Frame cycling
period
CLK-DATA
R,G,B
DATA-CLK
Symbol
VCC
1/tc
tc
Min.
3.0
10
0
-
Typ.
3.3
25
40
32
800
640
96
46
18
142
0
16.8
525
480
2
33
10
35
Max.
3.6
Tc-10
200
-
Unit
V
MHz
ns
us
tc
tc
tc
tc
tc
tc
ns
tc
ms
Hp
Hp
Hp
Hp
Hp
Hp
T1
-
800
-
tc
T2
-
640
-
tc
T3
-
480
-
T1
T4
520
525
800
T1
Dcd
Ddc
10
8
-
-
ns
ns
Hp
Hdp
Hpw
Hbp
Hfp
Hhc
Hvh
Vp
Vdp
Vpw
Vbp
Vfp
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd.
Page:13
PD050VL1
11-2) The Timing Diagram
a.1 Input signal range
tc
Dcd
R05-R00
G05-G00
B05-B00
Ddc
DENB
a.2 HSYNC timing
Hp
Hpw
HSYNC
Hdp
Hbp
Hfp
R,G,B Vaild data
a.3 CLK,HSYNC relationship
CLK
Hhc
HSYNC
a.4 HSYNC, VSYNC relationship
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:14
PD050VL1
a.5 VSYNC timing
DENB
a.6 DENB timing
Line 1
Line 480
Line 1
Line 2
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:15
PD050VL1
12. Power On Sequence
VCC
3.0V
3.0V
Logic Signal
0.3V
t1
t2
t3
OFF
Backlight
OFF
ON
10ms
10ms
1. 0Іt1Љ20ms
2. 0Іt2Љ50ms
3. 0Іt3Љ1s
13. Optical Characteristics
13-1) Specification:
Viewing
Angle
Parameter
Horizontal
Vertical
Contrast Ratio
Response time
CR
Rise
Fall
Brightness
Uniformity
Cross Talk
White Chromaticity
LED Life Time
Symbol
Ӱ21, Ӱ22
Ӱ12
Ӱ11
Tr
Tf
L
U
x
y
Condition
CRЇ10
At optimized
Viewing angle
Ӱ=0̓
Ӱ=0̓
Ӱ=0̓
Ӱ=0̓
+25к
MIN.
55
35
50
TYP.
60
40
55
MAX.
-
Unit
deg
deg
deg
200
400
-
-
15
30
25
50
400
450
70
80
3.5
0.28
0.31
0.34
0.31
0.34
0.37
20,000 30,000
-
ms
ms
cd/ф
%
%
hrs
Ta=25к
Remarks
Note 13-1
Note 13-2
Note 13-4
Note 13-3
Note 13-6
Note 13-7
Note 13-3
Note 13-5
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:16
PD050VL1
Note 13-1 : The definitions of viewing angle diagrams :
Note 13-2: CR =
Luminance when LCD is White
Luminance when LCD is Black
Contrast Ratio is measured in optimum common electrode voltage.
Note 13-3 : Topcon BM-7 (fast) luminance meter 1̓field of view is used in the testing (after 20~30
minutes operation).
Note 13-4 : The definitions of response time Tr and Tf:
White
Black
White
100%
90%
Brightness
10%
0%
Tr
Tf
Note 13-5: The “LED Life time “ is defined as the module brightness decrease to 50% original
Brightness that the ambient temperature is 25к and ILED =160mA.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:17
PD050VL1
Note 13-6 : The uniformity of LCD is defined as
U=
The Minimum Brightness of the 9 testing Points
The Maximum Brightness of the 9 testing Points
Luminance meter : BM-5A or BM-7 fast (TOPCON)
Measurement distance : 500 mm +/- 50 mm
Ambient illumination : < 1 Lux
Measuring direction : Perpendicular to the surface of module
The test pattern is white (Gray Level 63).
1 /6
2 /6
2 /6
1 /6
1 /6
2 /6
2 /6
1 /6
Note 13-7: Cross Talk (CTK) =
~YA-YB~ ͪ100%
YA
YA: Brightness of Pattern A
YB: Brightness of Pattern B
Luminance meter : BM 5A or BM-7 fast (TOPCON)
Measurement distance : 500 mm +/- 50 mm
Ambient illumination : < 1 Lux
Measuring direction : Perpendicular to the surface of module
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:18
PD050VL1
14. Handling Cautions
14-1) Mounting of module
a) Please power off the module when you connect the input/output connector.
b) Please connect the ground pattern of the inverter circuit surely. If the connection is not
perfect, some following problems may happen possibly.
1.The noise from the backlight unit will increase.
2.The output from inverter circuit will be unstable.
3.In some cases a part of module will heat.
c) Polarizer which is made of soft material and susceptible to flaw must be handled carefully.
d) Protective film (Laminator) is applied on surface to protect it against scratches and dirt.
e) Please following the tear off direction as figure14-1 to remove the protective film as slowly
as possible, so that electrostatic charge can be minimized.
14-2) Precautions in mounting
a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled, wipe it with
soft dry cloth.
b) Wipe off water drops or finger grease immediately. Long contact with water may cause
discoloration or spots.
c) TFT-LCD module uses glass, which breaks or cracks easily if dropped or bumped on hard
surface. Please handle with care.
d) Since CMOS LSI is used in the module. So take care of static electricity and earth yourself
when handling.
14-3) Adjusting module
a) Adjusting volumes on the rear face of the module have been set optimally before
shipment.
b) Therefore, do not change any adjusted values. If adjusted values are changed, the
specifications described may not be satisfied.
14-4) Others
a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours.
b) Store the module at a room temperature place.
c) The voltage of beginning electric discharge may over the normal voltage because of
leakage current from approach conductor by to draw lump read lead line around.
d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel.
Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet.
Wash it out immediately with soap.
e) Observe all other precautionary requirements in handling general electronic components.
f) Please adjust the voltage of common electrode as material of attachment by 1 module.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:19
PD050VL1
Figure 14-1 the way to peel off protective film
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:20
PD050VL1
15. Reliability Test
No
1
2
3
4
5
6
Test Item
High Temperature Storage Test
Low Temperature Storage Test
High Temperature Operation Test
Low Temperature Operation Test
High Temperature & High Humidity
Operation Test
Thermal Cycling Test
(non-operating)
7
Vibration Test
(non-operating)
8
Shock Test
(non-operating)
9
Electrostatic Discharge Test
(non-operating)
Test Condition
Ta = +90к, 240 hrs
Ta = -40к, 240 hrs
Ta = +80к, 240 hrs
Ta = -30к, 240 hrs
Ta = +60к, 90%RH, 240 hrs
-30к Ш +80к, 200 Cycles
30 min
30 min
FrequencyΚ10 ~ 55 HZ
AmplitudeΚ1 mm
Sweep time: 11 mins
Test Period: 6 Cycles for each direction of X, Y, Z
100G, 6ms
Direction: ̈́X, ̈́Y, ̈́Z
Cycle: 3 times
150pF, 330Ө
Air : ̈́15KV ; Contact : ̈́8KV
10 times/point , 9 points/panel face
Ta: ambient temperature
[Criteria]
In the standard conditions, there is not display function NG issue occurred. (including: line
defect ,no image).All the cosmetic specification is judged before the reliability stress.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:21
PD050VL1
16. Packing Diagram
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.Page:22