155W 2 & 3 Outputs with Battery Charger Function QE-155 series Features: Universal AC input / Full range Auto switch when power off (UPS function) Built-in constant current limit circuit Alarm signal for AC OK and Battery low (TTL open collector output or relay contact output) Protection: SCP, OLP, OVP Brown-out (Low AC Input Voltage) Battery low protection Battery polarity protection (by Resettable Fuses) Withstand 2G vibration test 3 years warranty QE-155-G MODEL Output Input Output Number DC Voltage Range Rated Current Max. Output Current Rated Power Ripple & Noise (Max.) Voltage Adj. Range Voltage Tolerance Line Regulation Load Regulation Setup, Rise Time Hold up Time (Typ.) Voltage Range Power Factor (Typ) Frequency Range Efficiency (Typ.) at 230VAC AC Current (Typ.) Inrush Current (Typ.) Leakage Current QE-155-GB QE-155-L QE-155-LB CH1 CH2 CH1 CH2 CH3 CH1 CH2 CH1 CH2 CH3 13.8V 13.8V 13.8V 13.8V 5V 27.6V 27.6V 27.6V 27.6V 5V 7.5A 3.7A 6.4A 3.7A 3A 3.6A 2A 3.1A 2A 3A 3.88A 10.1A 3.88A 3A 5.6A 2.1A 5.1A 2.1A 3A Note.8 11.2A 154.38W Note.11 154.56W 154.56W 155.76W Note.2 100mVp-p 150mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p CH1: ±10% 150mVp-p 100mVp-p CH1: ±10% Note.3 ±2% — ±2% — ±3% ±2% — ±2% — ±3% Note.4 ±0.5% — ±0.5% — ±0.5% ±0.5% — ±0.5% — ±0.5% Note.5 ±0.5% — ±0.5% — ±1.5% ±0.5% — ±0.5% — ±1.5% 2400ms, 20ms / 230VAC, 3200ms, 20ms / 115VAC at full load 30ms / 230VAC, 30ms / 115VAC at full load 90 ~ 264VAC, 127 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) PF > 0.94 at full load 47 ~ 63Hz 86% 85% 86% 85% 2.5A / 115VAC, 1.5A / 230VAC Cold Start 55A / 115VAC, 108A / 230VAC For earth < 1mA / 264VAC Above 110% rated output power CH1 / CH3 (GB / LB only) Over Load Protection Over Voltage Function Battery cut off AC OK Battery Low Working Temp. Working Humidity Environment Storage Temp. & Humidity Temp. Coefficient Vibration Safety Standards Withstand Voltage Isolation Resistance Safety & EMC EMI Conduction & Radiation Harmonic Current EMS Immunity Dimension (WxHxD) Others Packing Note Above 100% rated output current for CH2 Protection type: Hiccup mode, recovers automatically after fault condition is remove CH1: 115 ~ 150% rated output voltage Protection type: latch-off mode 10V ±4% 20V ±5% TTL open collector output Relay contact output TTL open collector output Relay contact output Battery low voltage < 12V ±3% Battery low voltage < 22V ±3% -20 ~ +70°C (Refer to de-rating curve) 20 ~ 90% RH non-condensing -40 ~ +85°C, 10 ~ 90% RH ±0.03% / °C (0 ~ 50°C) on CH1 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Certified UL 60950-1; EN 60950-1 I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC I/P-O/P: 100M Ohms / 500VDC Certified EN 55022; EN 61000-6-3 Certified EN 61000-3-2; EN 61000-3-3 Certified IEC 61000-4-2, 3, 4, 5, 6, 8, 11; ENV 50204; EN 55024; EN 61000-6-1; EN 61204-3 98x38x179 mm / 3.858x1.496x7.047 inch 0.64kg; 24pcs / 15.36kg / 1.29CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerance: includes setup time tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 10% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of setup time is measured at first cold start. Turning ON/OFF the power supply continuously may increase the setup time. 8. The total power output must not exceed the rated power. 9. CH2: Battery discharge current must not exceed 40% of the rated power. 10. Do not connect the GND port with B- port in your application to prevent product damage. 11. Please refer to the de-rating curve for the rated power. REV. A8 14/02/16 1 QE-155 series 155W 2 & 3 Outputs with Battery Charger Function Mechanical Drawings: Unit : mm[inch] 101 [3.976] 60 [2.362] FAN Air flow direction R1.75 [R0.069] 3.75 [0.148] 30 [1.181] 98 [3.858] 91.25 [3.593] 65 [2.559] 63 [2.48] 51.5 [2.028] 5 [0.197] 22 [0.866] 3.75 [0.148] 117 [4.606] 6.5 [0.256] R1.75 [R0.069] 3-M3 38 [1.496] 29 [1.142] 18 [0.709] 19.5 [0.768] 29 [1.142] Φ3.5 [Φ0.138] 13.15 [0.518] 179 [7.047] QE-155-G/L Alarm output Connector (CN2): JST B3B-XH or equivalent Terminal Pin No. Assignment (CN1) Assignment Pin No. Assignment Pin No. 1 AC/L 5 DC output V+ 2 AC/N 6 BAT+ 3 FG 7 BAT- 8 DC/DC Output +5V (GB/LB only) DC Output com 4 Assignment Pin No. 1 2 BAT LOW G (13.8V/20mA) L (27.6V/20mA) 3 Mating Housing Terminal JST XHP-3 or equivalent JST SXH-001 T-P0.6 or equivalent AC OK QE-155-GB/LB Alarm output Connector (CN2): JST B4B-XH or equivalent Assignment Pin No. 1 2 Mating Housing Terminal JST XHP-4 or equivalent JST SXH-001 T-P0.6 or equivalent AC OK 3 4 Bat. Low De-rating Curve: Load V.S Temp. Load V.S I/P Voltage 100 Ta=25°C 100 80 LOAD (%) LOAD (%) With 23 CFM min. With no Fan 60 40 20 -20 80 60 40 20 0 10 20 30 40 50 60 AMBIENT TEMPERATURE (°C) 70 (HORIZONTAL) 90 95 100 105 110 115 120 264 INPUT VOLTAGE (VAC) 60Hz REV. A8 14/04/16 2 155W 2 & 3 Outputs with Battery Charger Function QE-155 series For QE-155-G/L: Block Diagram AC OK ALARM CIRCUIT I/P EMI FILTER & RECTIFIER PFC CONTROL Bat. Low V+ RECTIFIERS & FILTER POWER SWITCHING COM B+ O.L.P. FG DETECTION CIRCUIT B- PWM CONTROL START CIRCUIT Battery Charger & Back up Control O.V.P. Alarm Signal for AC OK and Battery Low (1)Alarm Signal is sent out through "AC OK" & "Battery Low" pins. (2)An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 30mA. (3)Table 3.1 explain the alarm function built-in the power supply. Function Description Output of alarm The signal is "Low" when the power supply turns on Low (0.3V max. at 30mA) The signal turns to be "High" when the power supply turns OFF High or open (External applied voltage 50V max.) The signal is "Low" when the voltage of battery is under G:12V, L:22V Low (0.3V max. at 30mA) The signal is "High" when the voltage of battery is above G:12V, L: 22V High or open (External applied voltage 50V max.) AC OK Battery Low Table 3.1 Explanation of Alarm Signal AC OK (Battery low) V+ CN2 Pin3 G: 13.8V/20mA L: 27.6V/20mA CN2 Pin1(Pin2) CN2 Pin3 R V or CN1 Pin4 DC output GND Internal circuit of AC OK (Battery Low) CN2 Pin1(Pin2) External voltage and R (The max. sink is 30mA and 50V) REV. A8 14/04/16 3 155W 2 & 3 Outputs with Battery Charger Function QE-155 series For QE-155-GB/LB: Block Diagram AC OK ALARM CIRCUIT Bat. Low DC/DC Power Supply I/P EMI FILTER & RECTIFIER PFC CONTROL +5V V+ RECTIFIERS & FILTER POWER SWITCHING COM B+ FG O.L.P. START CIRCUIT DETECTION CIRCUIT PWM CONTROL O.V.P. B- Battery Charger & Back up Control Alarm Signal for AC OK and Battery Low (1)Alarm Signal is sent out through "AC OK" & "Battery Low" pins. (relay contact type) (2)An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. (3)Table 4.1 explain the alarm function built-in the power supply. AC OK (Battery low) Function Description Output of alarm The signal is “Low” when the power supply turns on Low or short The signal turns to be “High” when the power supply turns OFF High or open (External applied voltage 30V max.) The signal is “Low” when the voltage of battery is under GB:12V, LB:22V Low or short The signal is “High” when the voltage of battery is above GB:12V, LB:22V High or open (External applied voltage 30V max.) CN2 Pin1 (Pin3) AC OK Battery Low Table 4.1 Explanation of Alarm Signal External voltage source (V) and resistor (R) (The max. sink is 1A and 30V) Internal circuit of AC OK (Battery Low) CN2 Pin2 (Pin4) REV. A8 14/04/16 4