HEC-40LTB-PSAH Rev A1.0 A. Features High Efficiency (Up to 89%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated plastic case with IP20 and dry location. 1-10V, PWM, and resistance dimming function. Class 2 and SELV. B. Description The HEC-40LTB-PSAH Series operate from a 200 ~ 305Vac input range. They are designed to be highly efficient and highly reliable. Features include over voltage protection, short circuit protection, and over temperature protection. C. Models Output Current Output Voltage Range Input Voltage Range Note 1 Note 4 350mA 220 ~ 305Vac 18V~54V 500mA 220 ~ 305Vac 18V~54V 550mA 220 ~ 305Vac 18V~54V 700mA 220 ~ 305Vac 18V~54V 900mA 220 ~ 305Vac 18V~42V 1050mA 220 ~ 305Vac 18V~36V 1200mA 220 ~ 305Vac 18V~32V 1400mA 220 ~ 305Vac 18V~28V Voltage Max. Output Power Efficiency Power Factor Note 2 Note 2 40 W 89% 0.95 Model Number HEC-40LTB-PSAH Current 1 2 3 4 5 6 7 8 9 10 350mA ON ON - ON ON ON ON ON ON ON 500mA ON ON - ON ON ON ON ON ON - 550mA ON ON - ON ON ON ON ON - - 700mA ON - - ON ON ON ON - - - 42 Vdc 900mA ON - - ON ON ON - - - - 36 Vdc 1050mA ON - - ON ON - - - - - 32 Vdc 1200mA - - - ON - - - - - - 28 Vdc 1400mA - - - - - - - - - - 54 Vdc http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 1 HEC-40LTB-PSAH Rev A1.0 D. Electronic Specifications - Input Specifications Parameter Min. Typ. Max. Input Voltage (V) 200 - 305 Input Frequency (Hz) 47 Input AC Current (A) - - 0.25 Measured at full load and 277Vac input. Leakage Current (mA) - - 0.7 At 277Vac 60Hz input. Inrush Current (A) - - 40 At 220Vac input 25°C Cold Start. Duration=100µs, 10%Ipk-10%Ipk. - 0.16 A2s At 220Vac input 25°C Cold Start. Duration=100µs, 10%Ipk-10%Ipk. 0.9 - - - 20 25 Min. Typ. Max. Inrush Current (I2t) Power Factor Notes 63 At 277Vac input, full load. THD (%) - Output Specifications Parameter Notes Output Current (mA) Io = 350 mA 332 367 Io = 500 mA 475 525 Io = 550 mA 522 577 Io = 700 mA 665 735 Io = 900 mA 855 945 Io = 1050 mA 997 1102 Io = 1200 mA 1140 1260 Io = 1400 mA 1330 1470 No Load Output Voltage (V) Io = 350 mA Io = 500 mA Io = 550 mA Io = 700 mA ---- ---- 63 There will be no damage or hazardous conditions occurred with no loading. Io = 900 mA Io = 1050 mA Io = 1200 mA Io = 1400 mA http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 2 HEC-40LTB-PSAH Rev A1.0 Output Ripple Voltage (V) 10% ---- ---- Output Voltage Overshoot (%) - - 110 Line Regulation (%) - - ±3 Load Regulation (%) - - ±5 Turn-on Delay Time (s) - 0.5 1.0 Vomax Measured by 20 MHz bandwidth oscilloscopes and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor. At full load condition. Measured at 220Vac input. - General Specifications Parameter Min. Typ. Max. Notes Efficiency (%) Io = 350 mA 83 Io = 500 mA 86 Io = 550 mA 87 Io = 700 mA - - 88 Io = 900 mA 89 Io = 1050 mA 89 Io = 1200 mA 89 Io = 1400 mA 89 MTBF (hours) 320,000 Life Time (hours) Case Temperature (°C) - Dimensions Millimeters(L × W × H) - - 100,000 - - 85 Measured at full load and 277Vac input. Measured at full load 50°C ambient temperature (MIL-HDBK-217F). Measured at rated input voltage with full load, Case temperature=60°C @ Tc point.See life time vs. Tc curve for the details. 200 × 44 × 30.5 - Protection Functions Parameter Min. Over Voltage Protection Typ. Max. 1.50 Vo Notes Hiccup mode. The power supply shall be self-recovery when the fault condition is removed. Protection-Tc Hiccup mode. When the case temperature is higher than 110°C, the power supply output will turn off automatically; when the case temperature is lower than 75°C, the power supply output will be auto recovery. Short Circuit Protection No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. Over Temperature http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 3 HEC-40LTB-PSAH Rev A1.0 - Environmental Specifications Parameter Min. Typ. Max. Notes Operating Temperature (°C) -40 - +60 Humidity: 20% RH to 80% RH; See Derating Curve for more details. Storage Temperature (°C) -40 - +80 Humidity: 10% RH to 90% RH. - Safety and EMC Compliance Safety Category Standard UL/CUL UL8750, UL1310 Class 2, CSA C22.2 NO. 223-M91 Class 2. CE EN 61347-1, EN61347-2-13. EMI Standards Note 6 Notes EN 55015 Conducted emission Test & Radiated emission Test. EN 61000-3-2 Harmonic current emissions. EN 61000-3-3 Voltage fluctuations & flicker. FCC Part 15 FCC 47 CFR Part 15 Subpart B, ICES-003 Issue 4 ANSI C63.4-2003 EMS Standards Notes EN 61000-4-2 Electrostatic Discharge (ESD): 8 KV air discharge, 4 KV contact discharge. EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS. EN 61000-4-4 Electrical Fast Transient / Burst-EFT: Level 2, Criteria A. EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 1 KV. EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS. EN 61000-4-8 Power Frequency Magnetic Field Test. EN 61000-4-11 Voltage Dips. EN 61547 Electromagnetic Immunity Requirements Applies To Lighting Equipment. Notes: 1. Normal input voltage range 220~277Vac. 2. Measured at input 220V with a full load. 3. All specifications are typical at 25 °C unless otherwise stated. 4. Constant current operation region is preferably 75%~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static curve for more details. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation agai http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 4 HEC-40LTB-PSAH Rev A1.0 E. Dimming Control The dimmer control is operated from an input signal (DC voltage / PWM signal / Variable Resistor). Please refer to the diagram. Notes: 1. If the dimming pin is not used, Dimming pin can be open. Parameter Min. Typ. Max. 1-10V Dimming Voltage (V) 1 - + 10.8 PWM Signal 5 10 + 10.8 0~10K -0 - +10K ΩVariable Resistor (Ω) Notes - Dimming Model Output Voltage Range Parameter Min. Typ. Max. Io = 350 mA 35 - 54 Io = 500 mA 30 - 54 Io = 550 mA 30 - 54 Io = 700 mA 21 - 54 Io = 900 mA 21 - 42 Io = 1050 mA 21 - 36 Io = 1200 mA 21 - 32 Io = 1400 mA 21 - 28 Notes Measured at 220Vac input. http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 5 HEC-40LTB-PSAH Rev A1.0 Parameter Min. Typ. Max. Io = 350 mA 46 - 54 Io = 500 mA 40 - 54 Io = 550 mA 40 - 54 Io = 700 mA 31 - 54 Io = 900 mA 21 - 42 Io = 1050 mA 21 - 36 Io = 1200 mA 21 - 32 Io = 1400 mA 21 - 28 Notes Measured at 277Vac input. http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 6 HEC-40LTB-PSAH Rev A1.0 - DC Voltage Dimming Curve - PWM Signal Dimming Curve - Variable Resistor Curve http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 7 HEC-40LTB-PSAH Rev A1.0 F. Electronic Curve - Derating Curve - Static Curve - Power Factor Characteristics Curve http://www.hec-group.com.tw/ [email protected] - Efficiency Characteristics Curve TEL:+886-6-356-0606 FAX:+886-6-356-0505 8 HEC-40LTB-PSAH Rev A1.0 - Life Time vs. Case Temperature Curve G. Mechanical Outline http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 9 HEC-40LTB-PSAH Rev A1.0 H. RoHS Compliance Outline Our products comply with the European Directive 2011/65/EU, calling for the elimination of lead and other hazardous substances from electronic products. I. Revision History Change Date Description of Change Rev. Item 2014-11-25 A1.0 Datasheets Release http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 From To / / 10