A. Features
High Efficiency (Up to 89%).
Active Power Factor Correction (Typical 0.95).
Isolation Class II
All-Round Protection: OVP/SCP/OTP/OPP.
Fully isolated plastic case with IP20 and dry location.
1-10V, PWM, and resistance dimming function.
Class 2 and SELV.
B. Description
The HEC-40LTB-PSAH Series operate from a 200 ~ 305Vac input range. They are designed to be highly efficient and
highly reliable. Features include over voltage protection, short circuit protection, and over temperature protection.
C. Models
Output
Current
Output
Voltage
Range
Input Voltage
Range
Note 1
Note 4
350mA
220 ~ 305Vac
18V~54V
500mA
220 ~ 305Vac
18V~54V
550mA
220 ~ 305Vac
18V~54V
700mA
220 ~ 305Vac
18V~54V
900mA
220 ~ 305Vac
18V~42V
1050mA
220 ~ 305Vac
18V~36V
1200mA
220 ~ 305Vac
18V~32V
1400mA
220 ~ 305Vac
18V~28V
Voltage
Max.
Output
Power
Efficiency
Power Factor
Note 2
Note 2
40 W
89%
0.95
Model Number
HEC-40LTB-PSAH
Current
1
2
3
4
5
6
7
8
9
10
350mA
ON
ON
-
ON
ON
ON
ON
ON
ON
ON
500mA
ON
ON
-
ON
ON
ON
ON
ON
ON
-
550mA
ON
ON
-
ON
ON
ON
ON
ON
-
-
700mA
ON
-
-
ON
ON
ON
ON
-
-
-
42 Vdc
900mA
ON
-
-
ON
ON
ON
-
-
-
-
36 Vdc
1050mA
ON
-
-
ON
ON
-
-
-
-
-
32 Vdc
1200mA
-
-
-
ON
-
-
-
-
-
-
28 Vdc
1400mA
-
-
-
-
-
-
-
-
-
-
54 Vdc
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
1
HEC-40LTB-PSAH Rev A1.0
D. Electronic Specifications
- Input Specifications
Parameter
Min.
Typ.
Max.
Input Voltage (V)
200
-
305
Input Frequency (Hz)
47
Input AC Current (A)
-
-
0.25
Measured at full load and 277Vac input.
Leakage Current (mA)
-
-
0.7
At 277Vac 60Hz input.
Inrush Current (A)
-
-
40
At 220Vac input 25°C Cold Start. Duration=100µs,
10%Ipk-10%Ipk.
-
0.16 A2s
At 220Vac input 25°C Cold Start. Duration=100µs,
10%Ipk-10%Ipk.
0.9
-
-
-
20
25
Min.
Typ.
Max.
Inrush Current (I2t)
Power Factor
Notes
63
At 277Vac input, full load.
THD (%)
- Output Specifications
Parameter
Notes
Output Current (mA)
Io = 350 mA
332
367
Io = 500 mA
475
525
Io = 550 mA
522
577
Io = 700 mA
665
735
Io = 900 mA
855
945
Io = 1050 mA
997
1102
Io = 1200 mA
1140
1260
Io = 1400 mA
1330
1470
No Load Output Voltage (V)
Io = 350 mA
Io = 500 mA
Io = 550 mA
Io = 700 mA
----
----
63
There will be no damage or hazardous conditions
occurred with no loading.
Io = 900 mA
Io = 1050 mA
Io = 1200 mA
Io = 1400 mA
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
2
HEC-40LTB-PSAH Rev A1.0
Output Ripple Voltage (V)
10%
----
----
Output Voltage Overshoot (%)
-
-
110
Line Regulation (%)
-
-
±3
Load Regulation (%)
-
-
±5
Turn-on Delay Time (s)
-
0.5
1.0
Vomax
Measured by 20 MHz bandwidth oscilloscopes and
the output paralleled a 0.1uF ceramic capacitor and
a 10uF electrolytic capacitor.
At full load condition.
Measured at 220Vac input.
- General Specifications
Parameter
Min.
Typ.
Max.
Notes
Efficiency (%)
Io = 350 mA
83
Io = 500 mA
86
Io = 550 mA
87
Io = 700 mA
-
-
88
Io = 900 mA
89
Io = 1050 mA
89
Io = 1200 mA
89
Io = 1400 mA
89
MTBF (hours)
320,000
Life Time (hours)
Case Temperature (°C)
-
Dimensions Millimeters(L × W × H)
-
-
100,000
-
-
85
Measured at full load and 277Vac input.
Measured at full load 50°C ambient temperature
(MIL-HDBK-217F).
Measured at rated input voltage with full load, Case
temperature=60°C @ Tc point.See life time vs. Tc
curve for the details.
200 × 44 × 30.5
- Protection Functions
Parameter
Min.
Over Voltage Protection
Typ.
Max.
1.50 Vo
Notes
Hiccup mode. The power supply shall be
self-recovery when the fault condition is removed.
Protection-Tc
Hiccup mode. When the case temperature is higher than 110°C, the power supply
output will turn off automatically; when the case temperature is lower than 75°C, the
power supply output will be auto recovery.
Short Circuit Protection
No damage shall occur when any output operating in a short circuit condition. The
power supply shall be self-recovery when the fault condition is removed.
Over Temperature
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
3
HEC-40LTB-PSAH Rev A1.0
- Environmental Specifications
Parameter
Min.
Typ.
Max.
Notes
Operating Temperature (°C)
-40
-
+60
Humidity: 20% RH to 80% RH; See Derating Curve
for more details.
Storage Temperature (°C)
-40
-
+80
Humidity: 10% RH to 90% RH.
- Safety and EMC Compliance
Safety Category
Standard
UL/CUL
UL8750, UL1310 Class 2, CSA C22.2 NO. 223-M91 Class 2.
CE
EN 61347-1, EN61347-2-13.
EMI Standards Note 6
Notes
EN 55015
Conducted emission Test & Radiated emission Test.
EN 61000-3-2
Harmonic current emissions.
EN 61000-3-3
Voltage fluctuations & flicker.
FCC Part 15
FCC 47 CFR Part 15 Subpart B, ICES-003 Issue 4 ANSI C63.4-2003
EMS Standards
Notes
EN 61000-4-2
Electrostatic Discharge (ESD): 8 KV air discharge, 4 KV contact discharge.
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS.
EN 61000-4-4
Electrical Fast Transient / Burst-EFT: Level 2, Criteria A.
EN 61000-4-5
Surge Immunity Test: AC Power Line: line to line 1 KV.
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS.
EN 61000-4-8
Power Frequency Magnetic Field Test.
EN 61000-4-11
Voltage Dips.
EN 61547
Electromagnetic Immunity Requirements Applies To Lighting Equipment.
Notes:
1. Normal input voltage range 220~277Vac.
2. Measured at input 220V with a full load.
3. All specifications are typical at 25 °C unless otherwise stated.
4. Constant current operation region is preferably 75%~100% rated output voltage. This is the suitable operation region for LED related applications, but
please reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static curve for more details.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by
the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation agai
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
4
HEC-40LTB-PSAH Rev A1.0
E. Dimming Control
The dimmer control is operated from an input signal (DC voltage / PWM signal / Variable Resistor). Please refer to the
diagram.
Notes:
1. If the dimming pin is not used, Dimming pin can be open.
Parameter
Min.
Typ.
Max.
1-10V Dimming Voltage (V)
1
-
+ 10.8
PWM Signal
5
10
+ 10.8
0~10K
-0
-
+10K
ΩVariable Resistor (Ω)
Notes
- Dimming Model Output Voltage Range
Parameter
Min.
Typ.
Max.
Io = 350 mA
35
-
54
Io = 500 mA
30
-
54
Io = 550 mA
30
-
54
Io = 700 mA
21
-
54
Io = 900 mA
21
-
42
Io = 1050 mA
21
-
36
Io = 1200 mA
21
-
32
Io = 1400 mA
21
-
28
Notes
Measured at 220Vac input.
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
5
HEC-40LTB-PSAH Rev A1.0
Parameter
Min.
Typ.
Max.
Io = 350 mA
46
-
54
Io = 500 mA
40
-
54
Io = 550 mA
40
-
54
Io = 700 mA
31
-
54
Io = 900 mA
21
-
42
Io = 1050 mA
21
-
36
Io = 1200 mA
21
-
32
Io = 1400 mA
21
-
28
Notes
Measured at 277Vac input.
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
6
HEC-40LTB-PSAH Rev A1.0
- DC Voltage Dimming Curve
- PWM Signal Dimming Curve
- Variable Resistor Curve
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
7
HEC-40LTB-PSAH Rev A1.0
F. Electronic Curve
- Derating Curve
- Static Curve
- Power Factor Characteristics Curve
http://www.hec-group.com.tw/
[email protected]
- Efficiency Characteristics Curve
TEL:+886-6-356-0606
FAX:+886-6-356-0505
8
HEC-40LTB-PSAH Rev A1.0
- Life Time vs. Case Temperature Curve
G. Mechanical Outline
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
9
HEC-40LTB-PSAH Rev A1.0
H. RoHS Compliance Outline
Our products comply with the European Directive 2011/65/EU, calling for the elimination of lead and other hazardous
substances from electronic products.
I. Revision History
Change Date
Description of Change
Rev.
Item
2014-11-25
A1.0
Datasheets Release
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
From
To
/
/
10