CHIP COMMON MODE CHOKE COIL HDC0805

CHIP COMMON MODE CHOKE COIL
HDC0805-H SERIES
Introductions
This specification is applicable to chip type wire wounded common mode chokes. This is a product of
broadband common mode filter developed for high speed differential signal interfaces such as DVI and
HDMI. This product is suited for use on the transmission side of digital Tvs, DVD recorders and liquid
crystal projectors.
Features
* Cut off frequency in differential mode is 6GHz
? Operating temperature -40°C to +85°C.
? Excellent solderability and resistance to soldering heat.
? Suitable for flow and reflow soldering.
? Good dimensions, high reliability, and easy surface mount assembly.
Part Number
1
HDC
0805
S
T
900
-H
1
2
3
4
5
6
Chip Common Mode Choke Coil
2 Chip Size
CODE
L
W
H
UNIT
EIA
0.080
0.050
0.050
Inch
JIS
2.00
1.20
1.20
mm
3 General Characteristics
4 Taped In Reel. 2,000pcs/reel.
5 Typical Impedance at 100MHz
900 = 90 Ω
Material Structure
Ferrite
Copper Wire
Solder Termination
97
COMMON MODE HDC0805-H SERIES
6 AOBA's Internal Code
COMMON MODE CHOKE
WIRE WOUND TYPE
DIMENSION AND CONFIGURATION
2.60
1.2 ± 0.2
0.40
1.20
1.2 ± 0.2
2.0 ± 0.2
0.90
(1)
0.80
0.90
(2)
(0.4)
Remark :
( ) : Reference Value
Unit : m/m
(0.4)
(4)
EQUIVALENT CIRCUIT
: Electrode
(1)
(2)
(4)
(3)
(3)
(0.45)
NO POLARITY
(0.45)
Z vs Freq Plot
10000
Impedance ( Ω )
1000
100
10
1
0.1
1
10
100
1000
Freq (MHz)
ELECTRICAL SPECIFICATION
HDC0805 SERIES
Part Number
Common Mode
Impedance (Ω)
at 100MHz
Cut-off
Freq.
(GHz)
TDR
Impedance
( Ω )(Typ.)
Rated
Current
max(mA)
DC
Resistance
max (Ω)
EDC
(V)
Insulation
Resistance
min (MΩ)
HDC0805ST900-H
65min. (90~120 typ.)
6.0
100
300
0.30
20 max.
10
1. Impedance is measured in HP4287A at frequency of 100MHz.
2. For 15 °C rise.
98
COMMON MODE CHOKE WIRE WOUND TYPE
RELIABILITY SPECIFICATION
1 Scope
This specification applies to wired wounded chip common mode choke of the following
types used in electronic equipment :
*Material : Ferrite
2 Construction
*Configuration
& Dimension : Please refer to the attached figures and tables.
: HDC series shall consist of Ag followed by Nickel, then solder plating.
*Terminals
3 Operating Temperature Range
Operating Temperature Range is the scope of ambient temperature at which the common
mode choke can be operated continuously at rated current.
*Temp. Range : - 40 °C to + 85 °C
4 Recommended Soldering Conditions
Peak : 250 +5/-0°C
230°C or higher
2 to 6°C/s
180°C
3 to 6°C/s
Pre-heating Zone
150°C
90 ± 30s
2 to 4°C/s
30 ± 10s
Soldering Zone
Heating Time
5 Characteristics
Standard Atmospheric Conditions
Unless otherwise specified, the standard range of atmospheric conditions for making
measurements and tests are as follows :
*Ambient Temperature : 25°C ± 2 °C
: 60% to 70% (RH)
*Relative Humidity
: 86 Kpa to 106 Kpa
*Air Pressure
99
COMMON MODE CHOKE WIRE WOUND TYPE
RELIABILITY SPECIFICATION
CONDITION
ITEM
Electrical
Characteristics
SPECIFICATION
Common Mode
Impedance (Zc)
and Tolerance
Measuring Equipment : HP-4287A or equivalent.
Measuring Frequency : 100 ± 1MHz
Measuring Temperature : 25 ± 5°C
(Refer to Measurement Diagram )
Minimum 65 Ω.
Typical : 90~120Ω.
Insulation
Resistance
Measuring Voltage : Rated Voltage
Measuring Time : 1 minute max.
(Refer to Measurement Diagram )
10 mega ohms minimum
Dielectric
Withstanding
Voltage
Test Voltage : 2.5 times to Rated Voltage
Time : 1 to 5 seconds.
Charge current : 1mA max.
(Refer to Measurement Diagram )
No damage occurs when the
test voltage is applied.
Rated Current
Test Current : Rated Current
(Refer to Measurement Diagram )
Temperature Rise : ≤ 15°C
DC Resistance
(RDC)
Measured with current of 100mA max.
In case of doubt, measured by four terminal
method. (Refer to Measurement Diagram )
Within Specified Tolerance.
Table 1.
2.0 mm
Flexure
Strength
45(1.772)
45(1.772)
40(1.575)
100(3.937)
Change In Appearance
Without distinct damage
Change In Common Mode
Impedance :
Within ± 20%
Drop Test
Components shall be dropped three times on
a concrete or steel board at height of 1 M
naturally at any directions.
Vibration
(Random)
Components shall be randomly vibrated at
amplitude of 1.5mm and frequency of
10 - 55 Hz : 0.04 G / Hz, 1 minute at a period of
2 hours in each of the three mutually
perpendicular directions.
Withstanding Voltage :
No damaged
Solderability
Dip pads in flux and then in a solder bath
at 240 °C ± 5°C for 5 seconds.
A minimum of 80% of the
metalized area must be
covered with new solder.
Meet Table 1.
Resistance to
Soldering Heat
Preheat components at 80 to 120 °C for 1 minute.
Dip components into flux and then into a melted
solder bath at 260 ± 5°C for 5 ± 1 seconds.
Then components are to be tested after
4-48 hours at room temperature.
Components shall be reflow solder onto a
P. C. Board ( 240 ± 5°C for 20 seconds ).
Then a dynometer force gauge shall be applied
to any side of the component.
Components must
withstand a minimum force
of 1 Kg without any failure
of the termination to
component attachment.
Mechanical
Characteristics
Component
Adhesion
(Push Test)
100
Insulation Resistance :
10MΩ min
COMMON MODE CHOKE WIRE WOUND TYPE
RELIABILITY SPECIFICATION
ITEM
Endurance
Characteristics
CONDITION
SPECIFICATION
Cold
Temperature
Storage
Components shall be stored at temperature of
-40 °C ± 2 °C for 1000 (+48 hours -0 hour).
Then components shall be subjected to standard
atmospheric conditions for 4-48 hours. After that,
measurement shall be made.
Table 1.
Change In Appearance
Without distinct damage
High
Temperature
Storage
Components shall be stored at temperature
of +85 °C ± 2 °C for 1000 (+48 hours -0 hour).
Then components shall be subjected to standard
atmospheric conditions for 4-48 hour. After that,
measurement shall be made.
Change In Common Mode
Impedance:
Within ± 20%
Moisture
Resistance
Components shall be stored in the chamber at
40 °C at 90 - 95% R. H. for 1000 (+48 hours
-0 hour). Then components are to be tested
after 4-48 hours at room temperature.
Insulation Resistance:
100MΩ min
Temperature
Cycle
Each cycle shall consist of 30 minutes at -40°C
followed by 30 minutes at 85°C with a 10-15
minutes maximum transition time between
temperature extremes. Test duration is 100 cycles,
then components are to be tested after 4-48 hours
at room temperature.
High
Temperature
With Loaded
(Rated Current)
Components shall be stored at temperature
of +85 °C ± 2 °C for 1000 (+48 hours -0 hour)
with rated current applied.
Then components shall be subjected to standard
atmospheric conditions for 4-48 hour. After that,
measurement shall be made.
101
Withstanding Voltage:
No damaged
COMMON MODE CHOKE
WIRE WOUND TYPE
RELIABILITY SPECIFICATION
Measurement Diagram
Terminal to be Tested
When measuring and supplying the voltage, the following terminal is applied.
No.
ITEM
1
Common Mode Impedance
( Measurement Terminal )
2
Withstanding Voltage
( Measurement Terminal )
3
DC Resistance
( Measurement Terminal )
4
Rated Current
5
Insulation Resistance
Terminal to be Tested
Terminal
Terminal
Terminal
Terminal
Terminal
Terminal
Terminal
102
Terminal
PACKAGING INFORMATION
Packing Quantity
TYPE
PCS / REEL
HDC0805
2,000
Ø60
Ø178
1.0
9.0
Dimensions (unit:m/m)
TYPE
Chip
Cavity
2.0
1.75
Tape
Thickness
Insert
Pitch
3.5
A
B
F
K
T
1.50
2.35
4.00
1.45
0.23
8.0
B
± 0.10mm
Tolerance
HDC0805
Ø1.5
A
F
T
4.0
K
TAPE DIRECTION
Blank Portions
Chip Cavity
Top Tape Strength
The top tape requires a peel-off force of 0.2 to 0.7N in
the direction of the arrow as illustrated below
Leader
Top Tape
0 ~ 15°
o
160mm min
80mm min
Direction of tape feed
Base Tape
103
CHIP INDUCTOR SPECIFICATION
Operating Environment
Do not use this product under the following environmental conditions, on deterioration of
performance, such as insulation resistance may result from the use.
1 In corrosive gases ( acidic gases, alkaline gases, chlorine, sulfur gases, organic gases and etc.)
2 In the atmosphere where liquid such as organic solvent, may splash on the products.
Storage Condition
1 Storage period
Use the product within 12 months after delivered.
Solderability should be checked if this period is exceeded.
2 Storage environment conditions
*Product should be store in the warehouse on the following conditions.
Temperature : -10 ~ +40 °C
Humidity
: 20 to 70% relative humidity. No rapid change on temperature and humidity.
*Products should not be stored in corrosive gases, such as sulfurous, acid gases, alkaline gases,
to prevent the following deterioration.
Poor solderability due to the oxidized electrode.
*Products should be stored on the pallet for the prevention of the influence from humidity,
dust and so on.
*Products should be stored in the warehouse without heat shock, vibration, direct sunlight and
so on.
*Do not unpack the minimum package until immediately before use. After unpacking, re-seal
promptly or store in desiccator with a desiccant.
Delivery
Care should be taken when transporting or handling product to avoid excessive vibration or
mechanical shock.
104