350/500 Tuffline™ Entrances - Architectural Detail Manual

JULY, 2015
350/500 TufflineTM Entrances
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-065
FEATURES
Features
• 350 TufflineTM has 3-1/2" (88.9) vertical stile, 3-3/8" (85.8) top and 6-3/4" (171.5) bottom rail
• 500 TufflineTM has 5" (127) vertical stile, 5" (127) top and 6-3/4" (171.5) bottom rail
• Door is 2" (50.8) deep and has 3/16" (4.8) walls
• Dual moment welded corner construction
• Single acting
• Infills range from 1/4" (6.4) to 1" (25.4)
• Heavy duty offset pivots, butt hinges or continuous geared hinge
• MS locks or panic hardware
• Surface mounted or concealed closers
• Architects Classic push/pulls
• Double weatherstripping at meeting stiles; single exterior pile and interior twin-fin polymeric
adjustable astragal
• Frame is 2" (50.8) x 4-1/2" (114.3) and includes 3/16" (4.8) wall thickness at all hardware
attachment points
• Polymeric bulb weatherstripping in door frames
• PermanodicTM anodized finishes in seven choices
Optional Features
• PanelineTM exit device, PanelineTM EL exit device
• Various bottom and cross rails
• Optional 3/16" (4.8) wall thickness throughout frame
Product Applications
• 350 TufflineTM - constructed for unequaled strength and designed for high traffic and high
abuse applications such as schools, universities and sports stadiums
• 500 TufflineTM - offers the same performance features as the 350 TufflineTM except in a wide
stile design
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
• Painted finishes in standard and custom choices
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMA040
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 TufflineTM Entrances
BLANK PAGE
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
JULY, 2015
EC 97911-065
JULY, 2015
350/500 TufflineTM Entrances
INDEX
PICTORIAL VIEW................................................................................ 5
DOOR TYPES/SECT. DIMENSIONS................................................... 6
350/500 TUFFLINETM ENTRANCE DETAILS (Standard Frame)........ 7
350/500 TUFFLINETM ENTRANCE DETAILS (Heavy Frame)............. 8
350/500 TUFFLINETM ENTRANCE DETAILS ...................................... 9
ENTRANCE SIZES ........................................................................... 10
ENTRANCE OFFERINGS/APPLICATION CRITERIA ................ 11-12
PUSH-PULL HARDWARE ................................................................ 13
PANELINETM/PANELINETM EL EXIT DEVICE ................................... 14
DOOR AND FRAME OPTIONS ........................................................ 15
THERMAL CHARTS..................................................................... 16-28
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-065
3
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMA040
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 TufflineTM Entrances
BLANK PAGE
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
JULY, 2015
EC 97911-065
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
PICTORIAL VIEW
Security interlocks
SIGMA deep penetration fillet
and plug welds. Both inside
and outside of each corner.
#1 MECHANICAL FASTENING is accomplished
by attaching a 5/16" (7.9) thick extruded aluminum
channel clip to the vertical stile with 1/4"-20 heat
strengthened bolts and 3/16" thick steel nut plates
for a high strength welding base for attachment
horizontal member.
3/16" thick reinforcing channel
with steel back-up plate.
#2 SIGMA* DEEP PENETRATION PLUG WELDS
are made top and bottom after the horizontal
is properly positioned over the channel clip to
help provide the strongest door corner joint
currently available.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Extra heavy wall for hardware mounting.
DUAL MOMENT WELDED CORNER CONSTRUCTION
* An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA)
or also known as Metal Inert Gas (MIG).
kawneer.com
ADMA040
#3 SIGMA* FILLET WELDS along both top and
bottom webs of the rail extrusion complete the
welded corner construction.
5
6-3/4"
(171.5)
LOCK STILE
500 TUFFLINETM
WIDE STILE
STANDARD
LOCATIONS
1
1
STANDARD
EXIT DEVICE
4
3
2
2
PIVOT STILE
LOCK STILE
ADMA040
4
2
BOTTOM
OF DOOR
1
2
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
C
L OF CRASH BAR FOR
FALCON
DOOR TYPES/SECTION DIMENSIONS
3
4
3
4
3-1/2"
(88.9)
3-1/2"
(88.9)
5"
(127)
5"
(127)
PIVOT STILE
kawneer.com
© Kawneer Company, Inc., 2014
C
L
PANIC LOCK
CYLINDER
1690 = 40-5/8" (1031.9)
350 TUFFLINETM
MEDIUM STILE
1790 = 41-5/16" (1049.3)
350/500 TufflineTM Entrances
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3
5"
(127)
40-13/16"
(1036.6)
TOP
ATTACHMENT
6-3/4"
(171.5)
3-3/8"
(85.7)
44-5/16"
(1125.5)
6
JULY, 2015
EC 97911-065
SCALE 3" = 1' 0"
1
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
7
350/500 TUFFLINETM ENTRANCE DETAILS (STANDARD FRAME)
SCALE 3" = 1' - 0"
10
NOTE: ALL TUFFLINE ENTRANCES ARE SINGLE ACTING ONLY.
350 TUFFLINE DOOR SHOWN, 500 TUFFLINE SIMILAR.
TUFFLINE DOORS USE TUFFLINE DOOR FRAMES ONLY.
1
8
2
3
4
11
3
1
10 10A
6 or 6A
8 or 8A
11A
2
3
11A
11
4
5
12
9
9
9
9
JAMB
JAMB
LOCK STILE
MEETING STILE
PIVOT STILE
2"
(50.8)
TYP.
PIVOT STILE
3
PAIR OF SINGLE ACTING DOORS
1
2
JAMB
JAMB
PIVOT STILE
LOCK STILE
JAMB FOR 1" GLAZING
5
4
6
TRANSOM AREA
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
7 or 7A
OPTIONAL
CYLINDER
GUARD
4-1/2"
(114.3)
TYP.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
8
10A
1-1/8"
(28.6)
TRANSOM AREA
7
kawneer.com
ALTERNATE HALF JAMBS
7A
8
ADMA040
8A
6A
350/500 TufflineTM Entrances
8
350/500 TUFFLINE
TM
JULY, 2015
ENTRANCE DETAILS (HEAVY WALL FRAME)
EC 97911-065
SCALE 3"=1' - 0"
8
2
3
4
11
3
1
11A
2
10 10A
6 or 6A
8 or 8A
3
11
7 or 7A
11A
4
5
12
OPTIONAL
CYLINDER
GUARD
9
9
9
9
JAMB
JAMB
MEETING STILE
4-1/2"
(114.3)
TYP.
PIVOT STILE
PIVOT STILE
3
PAIR OF SINGLE ACTING DOORS
1
2
JAMB
JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2"
(50.8)
TYP.
LOCK STILE
PIVOT STILE
LOCK STILE
JAMB FOR 1" GLAZING
TRANSOM AREA
4
5
6A
1-1/8"
(28.6)
TRANSOM AREA
7
6
ALTERNATE HALF JAMBS
7A
8
ADMA040
8A
kawneer.com
© Kawneer Company, Inc., 2014
1
8
10A
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
10
NOTE: ALL TUFFLINE ENTRANCES ARE SINGLE ACTING ONLY.
350 TUFFLINE DOOR SHOWN, 500 TUFFLINE SIMILAR.
TUFFLINE DOORS USE TUFFLINE DOOR FRAMES ONLY.
HEAVY WALL FRAME IS OPTIONAL
© Kawneer Company, Inc., 2014
3/8"
(9.5)
1/2"
(12.7)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2"
(50.8)
TYP.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2015
kawneer.com
350/500 TufflineTM Entrances
EC 97911-065
10
SURFACE
CLOSER
8
9
10A
CONCEALED
CLOSER
CONCEALED
CLOSER
11
11A
1/4"
GLASS STOP
9
4-1/2"
(114.3)
ADMA040
9
350/500 TUFFLINE ENTRANCE DETAILS
SCALE 3" = 1' - 0"
10A
SURFACE
CLOSER
11B
350/500 TufflineTM Entrances
10
JULY, 2015
ENTRANCE SIZES
EC 97911-065
1/8"
(3.2)
MASONRY OPENING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DIMENSIONS ARE NOMINAL
OVERALL FRAME
3/32"
(2.4)
OVERALL FRAME
WITHOUT TRANSOM
Door Opening Dimension
3' 0" x 7' 0" ( 914 x 2134)
3' 6" x 7' 0" (1067 x 2134)
6' 0" x 7' 0" (1829 x 2134)
Overall Frame Dimension
3' 4" x 7' 2" (1016 x 2184)
3' 10" x 7' 2" (1168 x 2184)
6' 4" x 7' 2" (1930 x 2184)
Masonry Opening Dimension
3' 4-3/4" x 7' 2-3/8" (1035 x 2194)
3' 10-3/4" x 7' 2-3/8" (1187 x 2194)
6' 4-3/4" x 7' 2-3/8" (1949 x 2194)
WITH TRANSOM
Door Opening Dimension
Unchanged from above.
Overall Frame Dimension
Add 3' 1-3/4" (959) to above heights.
Masonry Opening Dimension
Add 3' 1-3/4" (959) to above heights.
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
STANDARD SIZES (TUFFLINETM FRAMES)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1/2"
(12.7)
3/16"
(4.8)
1/4"
(6.4)
DOOR OPENING
3/32"
(2.4)
1/8"
(3.2)
MASONRY OPENING
DOOR OPENING
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
ENTRANCE OFFERINGS
OPTIONAL
Doors
Medium stile 350 Tuffline doors prepared for attachment
hardware.
Wide stile 500 Tuffline door.
Door Sizes Std.
Standard sizes shown on page 10.
Any size up to 4'-0" x 9'-0" (1219 x 2743).
Glass Stops
Square glass stops for 1/4" infill.
Square glass stops for 5/8" (15.9) or 1" (25.4) infill. Beveled
glass stops for 1/4" (6.4) or 5/8" (15.9) infill.
Door Frames
Tuffline - 2" x 4" (50.8 x 101.6) for single glazing.
Tuffline Heavyweight Framing - 2" x 4" (50.8 x 101.6) for
single glazing.
Push-Pulls
Single Acting:
Single Acting:
Architects Classic Hardware "CO-9" Pull and
"CP-II" Push Bar.
Architects Classic Hardware "CO-9" Pull and
"CP" Push Bar.
Architects Classic Hardware
"CO-12" and "CP-II" push bar.
Architects Classic Hardware
"CO-12" and "CP" push bar.
Architects Classic Hardware
"CO-9"/"CO-9" Pulls.
Architects Classic Hardware
"CO-12"/"CO-12" Pulls.
Door Closers
Single Acting:
Norton 1601 adjustable or 1601 BF
adjustable surface closer with back-check
and with or without adjustable hold-open.
Single Acting:
LCN 4040 surface closer with or without
adjustable hold-open.
LCN 2030 or 5030 concealed closers with or
without hold-open.
Standard concealed overhead closer with
single acting offset arm.
LCN 1260 adjustable surface closer.
Falcon SC 60 Surface closer.
Hinging
Single Acting:
Kawneer heavy duty top and bottom offset
pivots (or) Kawneer top and bottom 5" x
4-1/2" (127 x 114.3) ball bearing butt hinge.
Intermediate
Pivots/Butts
Single Acting
Required:
Kawneer heavy duty intermediate offset
pivot (or) Kawneer 5" x 4-1/2" (127 x 114.3)
ball bearing butt hinge.
Power
Transfers
Single Acting:
Kawneer EL intermediate offset pivot (or)
Kawneer EL 4 1/2" x 4" (114.3 x 101.6) ball
bearing butt hinge with wire transfer (or)
EPT (Electric Power Transfer).
Power Supply
SP-1000X Power Supply: For use with PanelineTM EL exit
devices.
Locks Active Leaf
Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4)
diameter 5 pin cylinders.
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
STANDARD
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
11
kawneer.com
ADMA040
Single Acting:
Kawneer continuous gear hinge.
No substitution of outside hinge hardware
by others.
Adams-Rite #4510 latch lock.
Adams-Rite #1850A-500 short throw deadlock.
Adams-Rite #1850A-505 hookbolt lock.
Kawneer cylinder guard.
Kawneer thumbturn (in lieu of cylinder).
350/500 TufflineTM Entrances
JULY, 2015
ENTRANCE OFFERINGS/APPLICATION CRITERIA
STANDARD
One pair of Kawneer flush bolts in the
inactive leaf of a pair of doors.
Thresholds
1/2" x 4" (12.7 x 101.6) aluminum mill
finish threshold.
Weathering
Single
Acting:
Exit Device
Falcon 1690 Concealed Rod Exit
Device with or without a rim type cylinder.
Weathering system in the
door and frame consisting of a
dense, bulb polymeric material,
which remains resilient and
retains its weathering ability
under temperature extremes.
(The system is complete with
an optional EPDM blade gasket
sweep strip applied to the
bottom door rail with concealed
fasteners).
Falcon 1790 Rim Exit Device is a rim
type exit device with or without a rim type
cylinder. Pairs of doors require a RM-170
removable mullion.
PanelineTM exit device is a concealed rod
exit device applicable to single or pairs
of doors. It features an activating panel
contained within the door cross rail.
OPTIONAL
Controller is a 3-point locking system consisting of a two point locking device in the
inactive leaf in lieu of flush bolts, working in conjunction with the MS 1850A deadlock
in the active leaf. This combination provides for greater security than possible with
flush bolts and complies with the life safety considerations of building codes which
prohibit the use of flush bolts.
TM
Bottom Door Sweep
Falcon EL 1690 electric modification is also available.
Falcon EL 1790 electric modification is also available
PanelineTM EL electric modification is also available.
Falcon 1990 is a concealed rod exit device with or without a rim type cylinder.
Falcon 2090 is a rim type exit device with or without a rim type cylinder. Pairs of doors
require a removable aluminum mullion. RM-70 with the Falcon 2090 exit device.
Exit Device Pulls:
Optional Exit Device Pulls:
Architects Classic style "CO-9" Pull.
Architects Classic style "CO-12" Pull (except for PanelineTM and PanelineTM EL exit
devices).
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Architects Classic style "CPN" Pull
for PanelineTM and PanelineTM EL exit
devices.
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Locks Inactive Leaf
EC 97911-065
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
12
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
13
PUSH-PULL HARDWARE
REFER TO HARDWARE SECTION FOR COMPLETE HARDWARE INFORMATION.
ARCHITECTS CLASSIC (PUSH PULL SETS)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR AS STANDARD
DOUBLE ACTING DOORS USE CP PUSH BARS BACK TO BACK AS STANDARD.
CP-II/CP-II*
CP/CP
CO-9/CO-9
CO-12/CO-12
CO-9/CP-II
CO-12 /CP-II
CO-9/CP
CO-12/CP
ARCHITECTS CLASSIC (COMPONENTS)
STYLE CO-12
PULL
STYLE CO-9
PULL
STYLE CP PUSH BAR
STYLE CP-II* PUSH BAR
* CP-II PUSH BAR IS NOT TO BE USED FOR BACK TO BACK MOUNTING ON D/A DOORS.
EXIT DEVICES AND PULLS
EXIT DEVICES
KAWNEER PANELINE
/ PANELINE
EL
OVERALL W/ STOPS
TM
STYLE "CO-9"
PULL
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
TM
STYLE "CO-12"
PULL
RIM LATCH
Falcon 2090
CONCEALED ROD
Falcon 1990
STYLE"CPN" PULL ON
EXTERIOR OF DOOR
CONCEALED ROD
Falcon 1690
Falcon EL 1690
EXTERIOR VIEW OF 350 TUFFLINE DOOR (500 SIMILAR)
"CPN" PULL AND OPTIONAL CYLINDER GUARD SHOWN.
SEE PAGE 14 FOR COMPLETE
PANELINETM INFORMATION
kawneer.com
ADMA040
RIM LATCH
Falcon 1790
Falcon EL 1790
14
350/500 TufflineTM Entrances
PANELINE
TM
/ PANELINE
TM
JULY, 2015
EL EXIT DEVICE
EC 97911-065
SCALE 3" = 1' - 0"
PANELINETM EXIT DEVICE
The Optional PanelineTM EL device is designed for electrified access control and is compatible with most key pad and card reader
systems.
See Hardware Section for complete description of Paneline hardware, including finish of units.
2"
(50.8)
PanelineTM uses mortise cylinder in lieu of the normal rim-type.
Dummy Paneline units are not for use with any type of lock.
1-1/8"
(27.8)
INTERIOR VIEW
12
PUSH
PIVOT STILE TRIM FILLER WIDTH
VARIES WITH DOOR WIDTH
DOOR OPENING WIDTH
36-1/32"
(915.2)
TO BOTTOM
OF DOOR
500 DOOR
DOOR OPENING WIDTH
4'-0" (1219.2) MAX. - 2'-11 29/32" (912.0) MIN.
3'-0" (914.6) ADA MIN.
PANELINETM EL COMPONENTS
EXTERIOR VIEW
"CPN" PULL AND OPTIONAL CYLINDER GUARD SHOWN
ELECTRIC POWER TRANSFER
(EPT)
ADMA040
SP-1000X POWER SUPPLY
kawneer.com
© Kawneer Company, Inc., 2014
CROSS RAIL
(WITH EXIT DEVICE
AND CPN PULL HANDLE)
PUSH
5-7/8"
(149.2)
11/16"
(17.4)
4'-0" (1219.2) MAX. - 2'-10 13/32" (873.9) MIN.
3'-0" (914.6) ADA MIN.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5-7/8"
(149.2)
350 DOOR
8-7/16"
(214.3)
DOGGING LOCK
(Not Available with Paneline EL)
7-1/8"
(181.0)
LOCK STILE TRIM FILLER WIDTH
VARIES WITH STILE WIDTH
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
The PanelineTM concealed rod exit device for 350 and 500 TufflineTM doors will accommodate variations in stile width and
door width as shown in the following illustrations.
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
15
DOOR AND FRAME OPTIONS
SCALE 3" = 1' - 0"
1/4"
(6.4)
BOTTOM RAILS
5" (127)
8-7/16" (214.3)
6" (152.4)
4-1/8" (104.7)
TOP RAIL FOR LCN
CONCEALED CLOSER
HORIZONTAL/VERTICAL
CROSS RAILS
ALTERNATE PIVOT JAMB
2" (50.8)
CROSS RAIL
350
500
6" (152.4)
CROSS RAIL
(OPTIONAL)
HIGH BOTTOM RAILS
8-7/16" (214.3)
CROSS RAIL
INFILL OPTIONS
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COMMON LOCK STILE DOOR JAMB
10-1/4" (260.4)
COMMON LOCK STILE DOOR JAMB
2"
(50.8)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
REMOVABLE MULLION
MEETING STILE
FOR USE WITH
RIM PANIC
BEVELED STOPS
FOR 1/4" (6.4)
INFILL
SQUARE STOPS
FOR 1/4" (6.4) INFILL
(STANDARD)
kawneer.com
GLASS STOPS FOR 5/16" (7.9) MUNTINS
BEVELED STOPS
FOR 5/8" (15.9)
INFILL
BEVELED STOPS
FOR 1/4" (6.4) INFILL
WITH 5/16" (7.9) MUNTIN
BEVELED STOPS
FOR 5/8" (15.9) INFILL
WITH 5/16" (7.9) MUNTIN
SQUARE STOPS SQUARE STOPS
FOR 5/8" (15.9)
FOR 1" (25.4)
INFILL
INFILL
SQUARE STOPS
FOR 1/4" (6.4) INFILL
WITH 5/16" (7.9) MUNTIN
SQUARE STOPS
FOR 5/8" (15.9) INFILL
WITH 5/16" (7.9) MUNTIN
ADMA040
SQUARE STOPS
FOR 1" (25.4) INFILL
WITH 5/16" (7.9) MUNTIN
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL CHARTS
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
30.125"
(765.2)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
(DLO)
(F.H.)
75.75"
(1924.1)
(DLO)
7'-2"
(2184.4)
3'-4"
(1016.0)
(F.W.)
Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F
Total Daylight Opening
= 30.125" x 75.75" = 15.85 ft2
Total Projected Area
= 3'-4" x 7'-2" = 23.9 ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)100
= (15.85 ÷ 23.9)100 = 66%
System U-factor vs Percent of Glass Area
0.90
0.80
0.75
N
E IGN
PL S
M E
A D
EX OR
F
T
O
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
0.65
0.60
0.55
0.50
0.49
Btu
hr • ft2 • °F
System U-factor
COG
U-factor
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.70
0.45
0.40
0.35
0.30
0.25
0.20
85
80
75
70
Percent of Glass Area
65
60
Based on 66% glass and center of glass (COG) U-factor of 0.28
System U-factor is equal to 0.49 Btu/hr • ft2 • °F
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.85
66%
16
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL CHARTS
350 (SINGLE DOOR)
System U-factor (BTU/hr·ft2·oF)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.30 (1.71)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
ADMA040
17
COG
SHGC
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
350/500 TufflineTM Entrances
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
18
JULY, 2015
EC 97911-065
350 (SINGLE DOOR)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
350 (SINGLE DOOR)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.83
0.46
0.82
0.44
0.81
0.42
0.81
0.40
0.80
0.38
0.79
0.36
0.78
0.34
0.77
0.32
0.76
0.30
0.75
0.28
0.74
0.26
0.73
0.24
0.72
0.22
0.71
0.20
0.70
0.18
0.69
0.16
0.68
0.14
0.68
0.12
0.67
0.10
0.66
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
19
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.43
0.75
0.39
0.70
0.41
0.70
0.36
0.65
0.38
0.65
0.34
0.60
0.36
0.60
0.31
0.55
0.33
0.55
0.29
0.50
0.30
0.50
0.26
0.45
0.28
0.45
0.23
0.40
0.25
0.40
0.21
0.35
0.23
0.35
0.18
0.30
0.20
0.30
0.16
0.25
0.17
0.25
0.13
0.20
0.15
0.20
0.10
0.15
0.12
0.15
0.08
0.10
0.10
0.10
0.05
0.05
0.07
0.05
0.03
ADMA040
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL CHARTS
350 (PAIR OF DOORS)
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COG
U-factor
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
System U-factor (BTU/hr·ft2·oF)
20
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2015
kawneer.com
350/500 TufflineTM Entrances
EC 97911-065
THERMAL CHARTS
350 (PAIR OF DOORS)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMA040
21
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Overall U-Factor 4
0.47
0.79
0.46
0.78
0.44
0.77
0.42
0.76
0.40
0.75
0.38
0.74
0.36
0.73
0.34
0.72
0.32
0.71
0.30
0.70
0.28
0.69
0.26
0.68
0.24
0.67
0.22
0.66
0.20
0.65
0.18
0.64
0.16
0.63
0.14
0.62
0.12
0.61
0.10
0.60
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1920mm wide by
2090mm high (75-1/2" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.46
0.75
0.42
0.70
0.43
0.70
0.39
0.65
0.40
0.65
0.36
0.60
0.37
0.60
0.34
0.55
0.35
0.55
0.31
0.50
0.32
0.50
0.28
0.45
0.29
0.45
0.25
0.40
0.26
0.40
0.22
0.35
0.23
0.35
0.20
0.30
0.21
0.30
0.17
0.25
0.18
0.25
0.14
0.20
0.15
0.20
0.11
0.15
0.12
0.15
0.08
0.10
0.09
0.10
0.06
0.05
0.07
0.05
0.03
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350 (PAIR OF DOORS)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
22
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL CHARTS
500 (SINGLE DOOR)
System U-factor (BTU/hr·ft2·oF)
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
ADMA040
23
COG
SHGC
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
350/500 TufflineTM Entrances
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
24
JULY, 2015
EC 97911-065
500 (SINGLE DOOR)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
500 (SINGLE DOOR)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.87
0.46
0.86
0.44
0.85
0.42
0.84
0.40
0.84
0.38
0.83
0.36
0.82
0.34
0.81
0.32
0.81
0.30
0.80
0.28
0.79
0.26
0.78
0.24
0.77
0.22
0.77
0.20
0.76
0.18
0.75
0.16
0.74
0.14
0.73
0.12
0.73
0.10
0.72
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
25
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.38
0.75
0,33
0.70
0.36
0.70
0,31
0.65
0.34
0.65
0,29
0.60
0.32
0.60
0,27
0.55
0.29
0.55
0,25
0.50
0.27
0.50
0,22
0.45
0.25
0.45
0,20
0.40
0.23
0.40
0,18
0.35
0.21
0.35
0,16
0.30
0.18
0.30
0,13
0.25
0.16
0.25
0,11
0.20
0.14
0.20
0,09
0.15
0.12
0.15
0,07
0.10
0.09
0.10
0,04
0.05
0.07
0.05
0,02
ADMA040
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL CHARTS
500 (PAIR OF DOORS)
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COG
U-factor
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
System U-factor (BTU/hr·ft2·oF)
26
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2015
kawneer.com
350/500 TufflineTM Entrances
EC 97911-065
THERMAL CHARTS
500 (PAIR OF DOORS)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMA040
27
350/500 TufflineTM Entrances
JULY, 2015
EC 97911-065
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Overall U-Factor 4
0.47
0.82
0.46
0.82
0.44
0.81
0.42
0.80
0.40
0.79
0.38
0.78
0.36
0.77
0.34
0.77
0.32
0.76
0.30
0.75
0.28
0.74
0.26
0.73
0.24
0.72
0.22
0.71
0.20
0.70
0.18
0.70
0.16
0.69
0.14
0.68
0.12
0.67
0.10
0.66
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1920mm wide by
2090mm high (75-1/2" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.41
0.75
0.36
0.70
0.38
0.70
0.34
0.65
0.36
0.65
0.32
0.60
0.34
0.60
0.29
0.55
0.31
0.55
0.27
0.50
0.29
0.50
0.24
0.45
0.26
0.45
0.22
0.40
0.24
0.40
0.19
0.35
0.21
0.35
0.17
0.30
0.19
0.30
0.15
0.25
0.17
0.25
0.12
0.20
0.14
0.20
0.10
0.15
0.12
0.15
0.07
0.10
0.09
0.10
0.05
0.05
0.07
0.05
0.02
ADMA040
kawneer.com
© Kawneer Company, Inc., 2014
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
500 (PAIR OF DOORS)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
28