JULY, 2015 350/500 TufflineTM Entrances Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-065 FEATURES Features • 350 TufflineTM has 3-1/2" (88.9) vertical stile, 3-3/8" (85.8) top and 6-3/4" (171.5) bottom rail • 500 TufflineTM has 5" (127) vertical stile, 5" (127) top and 6-3/4" (171.5) bottom rail • Door is 2" (50.8) deep and has 3/16" (4.8) walls • Dual moment welded corner construction • Single acting • Infills range from 1/4" (6.4) to 1" (25.4) • Heavy duty offset pivots, butt hinges or continuous geared hinge • MS locks or panic hardware • Surface mounted or concealed closers • Architects Classic push/pulls • Double weatherstripping at meeting stiles; single exterior pile and interior twin-fin polymeric adjustable astragal • Frame is 2" (50.8) x 4-1/2" (114.3) and includes 3/16" (4.8) wall thickness at all hardware attachment points • Polymeric bulb weatherstripping in door frames • PermanodicTM anodized finishes in seven choices Optional Features • PanelineTM exit device, PanelineTM EL exit device • Various bottom and cross rails • Optional 3/16" (4.8) wall thickness throughout frame Product Applications • 350 TufflineTM - constructed for unequaled strength and designed for high traffic and high abuse applications such as schools, universities and sports stadiums • 500 TufflineTM - offers the same performance features as the 350 TufflineTM except in a wide stile design © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Painted finishes in standard and custom choices For specific product applications, Consult your Kawneer representative. kawneer.com ADMA040 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 TufflineTM Entrances BLANK PAGE ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JULY, 2015 EC 97911-065 JULY, 2015 350/500 TufflineTM Entrances INDEX PICTORIAL VIEW................................................................................ 5 DOOR TYPES/SECT. DIMENSIONS................................................... 6 350/500 TUFFLINETM ENTRANCE DETAILS (Standard Frame)........ 7 350/500 TUFFLINETM ENTRANCE DETAILS (Heavy Frame)............. 8 350/500 TUFFLINETM ENTRANCE DETAILS ...................................... 9 ENTRANCE SIZES ........................................................................... 10 ENTRANCE OFFERINGS/APPLICATION CRITERIA ................ 11-12 PUSH-PULL HARDWARE ................................................................ 13 PANELINETM/PANELINETM EL EXIT DEVICE ................................... 14 DOOR AND FRAME OPTIONS ........................................................ 15 THERMAL CHARTS..................................................................... 16-28 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-065 3 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMA040 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 TufflineTM Entrances BLANK PAGE ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JULY, 2015 EC 97911-065 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 PICTORIAL VIEW Security interlocks SIGMA deep penetration fillet and plug welds. Both inside and outside of each corner. #1 MECHANICAL FASTENING is accomplished by attaching a 5/16" (7.9) thick extruded aluminum channel clip to the vertical stile with 1/4"-20 heat strengthened bolts and 3/16" thick steel nut plates for a high strength welding base for attachment horizontal member. 3/16" thick reinforcing channel with steel back-up plate. #2 SIGMA* DEEP PENETRATION PLUG WELDS are made top and bottom after the horizontal is properly positioned over the channel clip to help provide the strongest door corner joint currently available. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Extra heavy wall for hardware mounting. DUAL MOMENT WELDED CORNER CONSTRUCTION * An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG). kawneer.com ADMA040 #3 SIGMA* FILLET WELDS along both top and bottom webs of the rail extrusion complete the welded corner construction. 5 6-3/4" (171.5) LOCK STILE 500 TUFFLINETM WIDE STILE STANDARD LOCATIONS 1 1 STANDARD EXIT DEVICE 4 3 2 2 PIVOT STILE LOCK STILE ADMA040 4 2 BOTTOM OF DOOR 1 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. C L OF CRASH BAR FOR FALCON DOOR TYPES/SECTION DIMENSIONS 3 4 3 4 3-1/2" (88.9) 3-1/2" (88.9) 5" (127) 5" (127) PIVOT STILE kawneer.com © Kawneer Company, Inc., 2014 C L PANIC LOCK CYLINDER 1690 = 40-5/8" (1031.9) 350 TUFFLINETM MEDIUM STILE 1790 = 41-5/16" (1049.3) 350/500 TufflineTM Entrances Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 5" (127) 40-13/16" (1036.6) TOP ATTACHMENT 6-3/4" (171.5) 3-3/8" (85.7) 44-5/16" (1125.5) 6 JULY, 2015 EC 97911-065 SCALE 3" = 1' 0" 1 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 7 350/500 TUFFLINETM ENTRANCE DETAILS (STANDARD FRAME) SCALE 3" = 1' - 0" 10 NOTE: ALL TUFFLINE ENTRANCES ARE SINGLE ACTING ONLY. 350 TUFFLINE DOOR SHOWN, 500 TUFFLINE SIMILAR. TUFFLINE DOORS USE TUFFLINE DOOR FRAMES ONLY. 1 8 2 3 4 11 3 1 10 10A 6 or 6A 8 or 8A 11A 2 3 11A 11 4 5 12 9 9 9 9 JAMB JAMB LOCK STILE MEETING STILE PIVOT STILE 2" (50.8) TYP. PIVOT STILE 3 PAIR OF SINGLE ACTING DOORS 1 2 JAMB JAMB PIVOT STILE LOCK STILE JAMB FOR 1" GLAZING 5 4 6 TRANSOM AREA © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 or 7A OPTIONAL CYLINDER GUARD 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8 10A 1-1/8" (28.6) TRANSOM AREA 7 kawneer.com ALTERNATE HALF JAMBS 7A 8 ADMA040 8A 6A 350/500 TufflineTM Entrances 8 350/500 TUFFLINE TM JULY, 2015 ENTRANCE DETAILS (HEAVY WALL FRAME) EC 97911-065 SCALE 3"=1' - 0" 8 2 3 4 11 3 1 11A 2 10 10A 6 or 6A 8 or 8A 3 11 7 or 7A 11A 4 5 12 OPTIONAL CYLINDER GUARD 9 9 9 9 JAMB JAMB MEETING STILE 4-1/2" (114.3) TYP. PIVOT STILE PIVOT STILE 3 PAIR OF SINGLE ACTING DOORS 1 2 JAMB JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2" (50.8) TYP. LOCK STILE PIVOT STILE LOCK STILE JAMB FOR 1" GLAZING TRANSOM AREA 4 5 6A 1-1/8" (28.6) TRANSOM AREA 7 6 ALTERNATE HALF JAMBS 7A 8 ADMA040 8A kawneer.com © Kawneer Company, Inc., 2014 1 8 10A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 10 NOTE: ALL TUFFLINE ENTRANCES ARE SINGLE ACTING ONLY. 350 TUFFLINE DOOR SHOWN, 500 TUFFLINE SIMILAR. TUFFLINE DOORS USE TUFFLINE DOOR FRAMES ONLY. HEAVY WALL FRAME IS OPTIONAL © Kawneer Company, Inc., 2014 3/8" (9.5) 1/2" (12.7) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2" (50.8) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2015 kawneer.com 350/500 TufflineTM Entrances EC 97911-065 10 SURFACE CLOSER 8 9 10A CONCEALED CLOSER CONCEALED CLOSER 11 11A 1/4" GLASS STOP 9 4-1/2" (114.3) ADMA040 9 350/500 TUFFLINE ENTRANCE DETAILS SCALE 3" = 1' - 0" 10A SURFACE CLOSER 11B 350/500 TufflineTM Entrances 10 JULY, 2015 ENTRANCE SIZES EC 97911-065 1/8" (3.2) MASONRY OPENING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DIMENSIONS ARE NOMINAL OVERALL FRAME 3/32" (2.4) OVERALL FRAME WITHOUT TRANSOM Door Opening Dimension 3' 0" x 7' 0" ( 914 x 2134) 3' 6" x 7' 0" (1067 x 2134) 6' 0" x 7' 0" (1829 x 2134) Overall Frame Dimension 3' 4" x 7' 2" (1016 x 2184) 3' 10" x 7' 2" (1168 x 2184) 6' 4" x 7' 2" (1930 x 2184) Masonry Opening Dimension 3' 4-3/4" x 7' 2-3/8" (1035 x 2194) 3' 10-3/4" x 7' 2-3/8" (1187 x 2194) 6' 4-3/4" x 7' 2-3/8" (1949 x 2194) WITH TRANSOM Door Opening Dimension Unchanged from above. Overall Frame Dimension Add 3' 1-3/4" (959) to above heights. Masonry Opening Dimension Add 3' 1-3/4" (959) to above heights. ADMA040 kawneer.com © Kawneer Company, Inc., 2014 STANDARD SIZES (TUFFLINETM FRAMES) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1/2" (12.7) 3/16" (4.8) 1/4" (6.4) DOOR OPENING 3/32" (2.4) 1/8" (3.2) MASONRY OPENING DOOR OPENING 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 ENTRANCE OFFERINGS OPTIONAL Doors Medium stile 350 Tuffline doors prepared for attachment hardware. Wide stile 500 Tuffline door. Door Sizes Std. Standard sizes shown on page 10. Any size up to 4'-0" x 9'-0" (1219 x 2743). Glass Stops Square glass stops for 1/4" infill. Square glass stops for 5/8" (15.9) or 1" (25.4) infill. Beveled glass stops for 1/4" (6.4) or 5/8" (15.9) infill. Door Frames Tuffline - 2" x 4" (50.8 x 101.6) for single glazing. Tuffline Heavyweight Framing - 2" x 4" (50.8 x 101.6) for single glazing. Push-Pulls Single Acting: Single Acting: Architects Classic Hardware "CO-9" Pull and "CP-II" Push Bar. Architects Classic Hardware "CO-9" Pull and "CP" Push Bar. Architects Classic Hardware "CO-12" and "CP-II" push bar. Architects Classic Hardware "CO-12" and "CP" push bar. Architects Classic Hardware "CO-9"/"CO-9" Pulls. Architects Classic Hardware "CO-12"/"CO-12" Pulls. Door Closers Single Acting: Norton 1601 adjustable or 1601 BF adjustable surface closer with back-check and with or without adjustable hold-open. Single Acting: LCN 4040 surface closer with or without adjustable hold-open. LCN 2030 or 5030 concealed closers with or without hold-open. Standard concealed overhead closer with single acting offset arm. LCN 1260 adjustable surface closer. Falcon SC 60 Surface closer. Hinging Single Acting: Kawneer heavy duty top and bottom offset pivots (or) Kawneer top and bottom 5" x 4-1/2" (127 x 114.3) ball bearing butt hinge. Intermediate Pivots/Butts Single Acting Required: Kawneer heavy duty intermediate offset pivot (or) Kawneer 5" x 4-1/2" (127 x 114.3) ball bearing butt hinge. Power Transfers Single Acting: Kawneer EL intermediate offset pivot (or) Kawneer EL 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with wire transfer (or) EPT (Electric Power Transfer). Power Supply SP-1000X Power Supply: For use with PanelineTM EL exit devices. Locks Active Leaf Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4) diameter 5 pin cylinders. © Kawneer Company, Inc., 2014 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STANDARD Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 11 kawneer.com ADMA040 Single Acting: Kawneer continuous gear hinge. No substitution of outside hinge hardware by others. Adams-Rite #4510 latch lock. Adams-Rite #1850A-500 short throw deadlock. Adams-Rite #1850A-505 hookbolt lock. Kawneer cylinder guard. Kawneer thumbturn (in lieu of cylinder). 350/500 TufflineTM Entrances JULY, 2015 ENTRANCE OFFERINGS/APPLICATION CRITERIA STANDARD One pair of Kawneer flush bolts in the inactive leaf of a pair of doors. Thresholds 1/2" x 4" (12.7 x 101.6) aluminum mill finish threshold. Weathering Single Acting: Exit Device Falcon 1690 Concealed Rod Exit Device with or without a rim type cylinder. Weathering system in the door and frame consisting of a dense, bulb polymeric material, which remains resilient and retains its weathering ability under temperature extremes. (The system is complete with an optional EPDM blade gasket sweep strip applied to the bottom door rail with concealed fasteners). Falcon 1790 Rim Exit Device is a rim type exit device with or without a rim type cylinder. Pairs of doors require a RM-170 removable mullion. PanelineTM exit device is a concealed rod exit device applicable to single or pairs of doors. It features an activating panel contained within the door cross rail. OPTIONAL Controller is a 3-point locking system consisting of a two point locking device in the inactive leaf in lieu of flush bolts, working in conjunction with the MS 1850A deadlock in the active leaf. This combination provides for greater security than possible with flush bolts and complies with the life safety considerations of building codes which prohibit the use of flush bolts. TM Bottom Door Sweep Falcon EL 1690 electric modification is also available. Falcon EL 1790 electric modification is also available PanelineTM EL electric modification is also available. Falcon 1990 is a concealed rod exit device with or without a rim type cylinder. Falcon 2090 is a rim type exit device with or without a rim type cylinder. Pairs of doors require a removable aluminum mullion. RM-70 with the Falcon 2090 exit device. Exit Device Pulls: Optional Exit Device Pulls: Architects Classic style "CO-9" Pull. Architects Classic style "CO-12" Pull (except for PanelineTM and PanelineTM EL exit devices). Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Architects Classic style "CPN" Pull for PanelineTM and PanelineTM EL exit devices. ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Locks Inactive Leaf EC 97911-065 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 12 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 13 PUSH-PULL HARDWARE REFER TO HARDWARE SECTION FOR COMPLETE HARDWARE INFORMATION. ARCHITECTS CLASSIC (PUSH PULL SETS) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR AS STANDARD DOUBLE ACTING DOORS USE CP PUSH BARS BACK TO BACK AS STANDARD. CP-II/CP-II* CP/CP CO-9/CO-9 CO-12/CO-12 CO-9/CP-II CO-12 /CP-II CO-9/CP CO-12/CP ARCHITECTS CLASSIC (COMPONENTS) STYLE CO-12 PULL STYLE CO-9 PULL STYLE CP PUSH BAR STYLE CP-II* PUSH BAR * CP-II PUSH BAR IS NOT TO BE USED FOR BACK TO BACK MOUNTING ON D/A DOORS. EXIT DEVICES AND PULLS EXIT DEVICES KAWNEER PANELINE / PANELINE EL OVERALL W/ STOPS TM STYLE "CO-9" PULL © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. TM STYLE "CO-12" PULL RIM LATCH Falcon 2090 CONCEALED ROD Falcon 1990 STYLE"CPN" PULL ON EXTERIOR OF DOOR CONCEALED ROD Falcon 1690 Falcon EL 1690 EXTERIOR VIEW OF 350 TUFFLINE DOOR (500 SIMILAR) "CPN" PULL AND OPTIONAL CYLINDER GUARD SHOWN. SEE PAGE 14 FOR COMPLETE PANELINETM INFORMATION kawneer.com ADMA040 RIM LATCH Falcon 1790 Falcon EL 1790 14 350/500 TufflineTM Entrances PANELINE TM / PANELINE TM JULY, 2015 EL EXIT DEVICE EC 97911-065 SCALE 3" = 1' - 0" PANELINETM EXIT DEVICE The Optional PanelineTM EL device is designed for electrified access control and is compatible with most key pad and card reader systems. See Hardware Section for complete description of Paneline hardware, including finish of units. 2" (50.8) PanelineTM uses mortise cylinder in lieu of the normal rim-type. Dummy Paneline units are not for use with any type of lock. 1-1/8" (27.8) INTERIOR VIEW 12 PUSH PIVOT STILE TRIM FILLER WIDTH VARIES WITH DOOR WIDTH DOOR OPENING WIDTH 36-1/32" (915.2) TO BOTTOM OF DOOR 500 DOOR DOOR OPENING WIDTH 4'-0" (1219.2) MAX. - 2'-11 29/32" (912.0) MIN. 3'-0" (914.6) ADA MIN. PANELINETM EL COMPONENTS EXTERIOR VIEW "CPN" PULL AND OPTIONAL CYLINDER GUARD SHOWN ELECTRIC POWER TRANSFER (EPT) ADMA040 SP-1000X POWER SUPPLY kawneer.com © Kawneer Company, Inc., 2014 CROSS RAIL (WITH EXIT DEVICE AND CPN PULL HANDLE) PUSH 5-7/8" (149.2) 11/16" (17.4) 4'-0" (1219.2) MAX. - 2'-10 13/32" (873.9) MIN. 3'-0" (914.6) ADA MIN. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5-7/8" (149.2) 350 DOOR 8-7/16" (214.3) DOGGING LOCK (Not Available with Paneline EL) 7-1/8" (181.0) LOCK STILE TRIM FILLER WIDTH VARIES WITH STILE WIDTH Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. The PanelineTM concealed rod exit device for 350 and 500 TufflineTM doors will accommodate variations in stile width and door width as shown in the following illustrations. 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 15 DOOR AND FRAME OPTIONS SCALE 3" = 1' - 0" 1/4" (6.4) BOTTOM RAILS 5" (127) 8-7/16" (214.3) 6" (152.4) 4-1/8" (104.7) TOP RAIL FOR LCN CONCEALED CLOSER HORIZONTAL/VERTICAL CROSS RAILS ALTERNATE PIVOT JAMB 2" (50.8) CROSS RAIL 350 500 6" (152.4) CROSS RAIL (OPTIONAL) HIGH BOTTOM RAILS 8-7/16" (214.3) CROSS RAIL INFILL OPTIONS © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COMMON LOCK STILE DOOR JAMB 10-1/4" (260.4) COMMON LOCK STILE DOOR JAMB 2" (50.8) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. REMOVABLE MULLION MEETING STILE FOR USE WITH RIM PANIC BEVELED STOPS FOR 1/4" (6.4) INFILL SQUARE STOPS FOR 1/4" (6.4) INFILL (STANDARD) kawneer.com GLASS STOPS FOR 5/16" (7.9) MUNTINS BEVELED STOPS FOR 5/8" (15.9) INFILL BEVELED STOPS FOR 1/4" (6.4) INFILL WITH 5/16" (7.9) MUNTIN BEVELED STOPS FOR 5/8" (15.9) INFILL WITH 5/16" (7.9) MUNTIN SQUARE STOPS SQUARE STOPS FOR 5/8" (15.9) FOR 1" (25.4) INFILL INFILL SQUARE STOPS FOR 1/4" (6.4) INFILL WITH 5/16" (7.9) MUNTIN SQUARE STOPS FOR 5/8" (15.9) INFILL WITH 5/16" (7.9) MUNTIN ADMA040 SQUARE STOPS FOR 1" (25.4) INFILL WITH 5/16" (7.9) MUNTIN 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 30.125" (765.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. (DLO) (F.H.) 75.75" (1924.1) (DLO) 7'-2" (2184.4) 3'-4" (1016.0) (F.W.) Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F Total Daylight Opening = 30.125" x 75.75" = 15.85 ft2 Total Projected Area = 3'-4" x 7'-2" = 23.9 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (15.85 ÷ 23.9)100 = 66% System U-factor vs Percent of Glass Area 0.90 0.80 0.75 N E IGN PL S M E A D EX OR F T O (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.65 0.60 0.55 0.50 0.49 Btu hr • ft2 • °F System U-factor COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.70 0.45 0.40 0.35 0.30 0.25 0.20 85 80 75 70 Percent of Glass Area 65 60 Based on 66% glass and center of glass (COG) U-factor of 0.28 System U-factor is equal to 0.49 Btu/hr • ft2 • °F ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.85 66% 16 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL CHARTS 350 (SINGLE DOOR) System U-factor (BTU/hr·ft2·oF) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area COG U-factor 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.30 (1.71) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMA040 17 COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADMA040 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 350/500 TufflineTM Entrances Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 18 JULY, 2015 EC 97911-065 350 (SINGLE DOOR) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 350 (SINGLE DOOR) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.83 0.46 0.82 0.44 0.81 0.42 0.81 0.40 0.80 0.38 0.79 0.36 0.78 0.34 0.77 0.32 0.76 0.30 0.75 0.28 0.74 0.26 0.73 0.24 0.72 0.22 0.71 0.20 0.70 0.18 0.69 0.16 0.68 0.14 0.68 0.12 0.67 0.10 0.66 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 19 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.43 0.75 0.39 0.70 0.41 0.70 0.36 0.65 0.38 0.65 0.34 0.60 0.36 0.60 0.31 0.55 0.33 0.55 0.29 0.50 0.30 0.50 0.26 0.45 0.28 0.45 0.23 0.40 0.25 0.40 0.21 0.35 0.23 0.35 0.18 0.30 0.20 0.30 0.16 0.25 0.17 0.25 0.13 0.20 0.15 0.20 0.10 0.15 0.12 0.15 0.08 0.10 0.10 0.10 0.05 0.05 0.07 0.05 0.03 ADMA040 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL CHARTS 350 (PAIR OF DOORS) 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF) 20 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2015 kawneer.com 350/500 TufflineTM Entrances EC 97911-065 THERMAL CHARTS 350 (PAIR OF DOORS) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADMA040 21 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.47 0.79 0.46 0.78 0.44 0.77 0.42 0.76 0.40 0.75 0.38 0.74 0.36 0.73 0.34 0.72 0.32 0.71 0.30 0.70 0.28 0.69 0.26 0.68 0.24 0.67 0.22 0.66 0.20 0.65 0.18 0.64 0.16 0.63 0.14 0.62 0.12 0.61 0.10 0.60 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.46 0.75 0.42 0.70 0.43 0.70 0.39 0.65 0.40 0.65 0.36 0.60 0.37 0.60 0.34 0.55 0.35 0.55 0.31 0.50 0.32 0.50 0.28 0.45 0.29 0.45 0.25 0.40 0.26 0.40 0.22 0.35 0.23 0.35 0.20 0.30 0.21 0.30 0.17 0.25 0.18 0.25 0.14 0.20 0.15 0.20 0.11 0.15 0.12 0.15 0.08 0.10 0.09 0.10 0.06 0.05 0.07 0.05 0.03 ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350 (PAIR OF DOORS) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL CHARTS 500 (SINGLE DOOR) System U-factor (BTU/hr·ft2·oF) COG U-factor 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMA040 23 COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADMA040 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 350/500 TufflineTM Entrances Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 24 JULY, 2015 EC 97911-065 500 (SINGLE DOOR) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 500 (SINGLE DOOR) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.87 0.46 0.86 0.44 0.85 0.42 0.84 0.40 0.84 0.38 0.83 0.36 0.82 0.34 0.81 0.32 0.81 0.30 0.80 0.28 0.79 0.26 0.78 0.24 0.77 0.22 0.77 0.20 0.76 0.18 0.75 0.16 0.74 0.14 0.73 0.12 0.73 0.10 0.72 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 25 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.38 0.75 0,33 0.70 0.36 0.70 0,31 0.65 0.34 0.65 0,29 0.60 0.32 0.60 0,27 0.55 0.29 0.55 0,25 0.50 0.27 0.50 0,22 0.45 0.25 0.45 0,20 0.40 0.23 0.40 0,18 0.35 0.21 0.35 0,16 0.30 0.18 0.30 0,13 0.25 0.16 0.25 0,11 0.20 0.14 0.20 0,09 0.15 0.12 0.15 0,07 0.10 0.09 0.10 0,04 0.05 0.07 0.05 0,02 ADMA040 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL CHARTS 500 (PAIR OF DOORS) 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF) 26 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2015 kawneer.com 350/500 TufflineTM Entrances EC 97911-065 THERMAL CHARTS 500 (PAIR OF DOORS) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADMA040 27 350/500 TufflineTM Entrances JULY, 2015 EC 97911-065 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.47 0.82 0.46 0.82 0.44 0.81 0.42 0.80 0.40 0.79 0.38 0.78 0.36 0.77 0.34 0.77 0.32 0.76 0.30 0.75 0.28 0.74 0.26 0.73 0.24 0.72 0.22 0.71 0.20 0.70 0.18 0.70 0.16 0.69 0.14 0.68 0.12 0.67 0.10 0.66 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.41 0.75 0.36 0.70 0.38 0.70 0.34 0.65 0.36 0.65 0.32 0.60 0.34 0.60 0.29 0.55 0.31 0.55 0.27 0.50 0.29 0.50 0.24 0.45 0.26 0.45 0.22 0.40 0.24 0.40 0.19 0.35 0.21 0.35 0.17 0.30 0.19 0.30 0.15 0.25 0.17 0.25 0.12 0.20 0.14 0.20 0.10 0.15 0.12 0.15 0.07 0.10 0.09 0.10 0.05 0.05 0.07 0.05 0.02 ADMA040 kawneer.com © Kawneer Company, Inc., 2014 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 500 (PAIR OF DOORS) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28