Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 FEATURES Features • 260 InsulcladTM has 2-11/16" (68.3) vertical stile, 2-13/16" (71.4) top and 4-7/16" (112.7) bottom rail • 360 InsulcladTM has 4-1/16" (103.2) vertical stile, 4-1/16" (103.2) top and 7-1/16" (179.4) bottom rail • 560 InsulcladTM has 5-9/16" (141.3) vertical stile, 5-9/16" (141.3) top and 7-1/16" (179.4) bottom rail • Door is 2-1/4" (57.2) deep • Dual moment welded corner construction • Door incorporates an extruded PVC thermal break • Single acting • 1" (25.4) infill • Offset pivots, butt hinges or continuous geared hinge • MS locks or Exit Device hardware • Surface mounted or concealed closers • Architects Classic push/pulls • Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles • Polymeric bulb weatherstripping in door frames • PermanodicTM anodized finishes in seven choices Optional Features • Variety of bottom rail and cross rails • Two-color finish capability © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Painted finishes in standard and custom choices Product Applications • 260 InsulcladTM – engineered for thermal efficiency in moderate traffic applications such as offices, stores and apartment buildings • 360 InsulcladTM – provides thermal efficiency and extra strength for schools, institutions and other high traffic applications. • 560 InsulcladTM – designed for thermal efficiency with a monumental visual statement for banks, libraries or buildings that experience heavy traffic conditions For specific product applications, Consult your Kawneer representative. kawneer.com ADMA070 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 BLANK PAGE EC 97911-065 ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 INDEX 3 PICTORIAL VIEW................................................................................ 5 DOOR TYPES/SECT. DIMENSIONS................................................... 6 CONSTRUCTION DETAILS................................................................. 7 ENTRANCE DIMENSIONS.................................................................. 8 HARDWARE STANDARDS............................................................9, 10 PUSH PULL HARDWARE................................................................. 11 EXIT DEVICE..................................................................................... 12 OPTIONAL DOOR DETAILS............................................................. 13 WINDLOAD/DEADLOAD CHARTS................................................... 14 THERMAL CHARTS..................................................................... 15-24 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AUGUST, 2015 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMA070 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 BLANK PAGE EC 97911-065 ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 PICTORIAL VIEW PIVOT JAMB SHEAR BLOCK TRANSOM HEAD SHEAR BLOCK TRANSOM BAR LOCK JAMB TOP PIVOT FRAME PORTION WEATHERING BOTTOM PIVOT FRAME PORTION kawneer.com THRESHOLD TOP PIVOT DOOR PORTION THRESHOLD CLIP INSULCLADTM 260 DOOR ADMA070 5 TYPICAL 2-1/4" (57.2) 3-7/8" (98.4) 2 2-1/8" (54.0) 6-1/2" (165.1) 3 3 9/16" (14.3) SINGLE ACTING TYPICAL 2 TOP ATTACHMENT TOP ATTACHMENT CL OF CYL. 2 BOTTOM OF DOOR 1 2 SINGLE ACTING ADMA070 STANDARD EXIT DEVICE C L PANIC LOCK CYLINDER 3 2 3 3 3-1/2" (88.9) 5" (127) AUGUST, 2015 DOOR TYPES/SECTION DIMENSIONS EC 97911-065 BOTTOM OF DOOR 2 SINGLE ACTING kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. C L OF CRASH BAR FOR FALCON C L OF CRASH BAR FOR ADAMS RITE 1 1690 = 40-5/8" (1031.9) STANDARD LOCATIONS 1790 = 41-5/16" (1049.3) 1 8600 = 41-11/16" (1058.9) 1 8400 = 40-13/16" (1036.6) 360 MEDIUM STILE 41-9/16" (1042) 44-5/16" (1125.5) 260/360/560 InsulcladTM Thermal Entrances © Kawneer Company, Inc., 2015 1 3-1/2" (88.9) 40-13/16" (1036.6) 260 NARROW STILE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/4" (57.2) 3 5" (127) 9/16" (14.3) STANDARD LOCATIONS 6-1/2" (165.1) TYPICAL 44-5/16" (1125.5) 6 SCALE 3" = 1' 0" 560 WIDE STILE 1 2-7/32" (56.4) TYPICAL © Kawneer Company, Inc., 2015 3/32" (2.4) kawneer.com 1 452041 INSERT 5 3 1 6 4 3 2 1 6 1/8" (3.2) 3/32" (2.4) 3 5 ADMA070 2" (50.8) 7 8 4 2 3 6 1/8" (3.2) 2" (50.8) 2 2" (50.8) 5 1/8" (3.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 2" (50.8) 1/2" (12.7) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 ENTRANCE DETAILS SCALE 3" = 1'-0" TRIFABTM VG 451T CENTER FRAMING SHOWN. 260 INSULCLAD SHOWN, 360 AND 560 INSULCLAD SIMILAR. OTHER FRAMING OPTIONS AVAILABLE. CONSULT YOUR KAWNEER REPRESENTATIVE. 7 8 1 3 6 ELEVATION IS NUMBER KEYED TO DETAILS. 7 2" (50.8) 8 4 6 7 8 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 ENTRANCE DIMENSIONS EC 97911-065 SCALE 3" = 1' 0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DIMENSIONS ARE NOMINAL MASONRY OPENING OVERALL FRAME 3/32" (2.4) 1/8" (3.2) WITHOUT TRANSOM Door Opening Dimension 3' 0" x 7' 0" ( 914 x 2134) 3' 6" x 7' 0" (1067 x 2134) 6' 0" x 7' 0" (1829 x 2134) Overall Frame Dimension 3' 4" x 7' 2" (1016 x 2184) 3' 10" x 7' 2" (1168 x 2184) 6' 4" x 7' 2" (1930 x 2184) Masonry Opening Dimension 3' 4-1/2" x 7' 2-1/4" (1029 x 2191) 3' 10-1/2" x 7' 2-1/4" (1181 x 2191) 6' 4-1/2" x 7' 2-1/4" (1943 x 2191) WITH TRANSOM Door Opening Dimension Unchanged from above. Overall Frame Dimension Add 3' 2" (965) to above heights. Masonry Opening Dimension Add 3' 2-1/2" (978) to above heights. ADMA070 kawneer.com © Kawneer Company, Inc., 2015 STANDARD SIZES (TRIFABTM VG 451T CENTER FRAMES) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1/2" (12.7) 3/16" (4.3) 1/8" (3.2) DOOR OPENING 3/32" (2.4) OVERALL FRAME MASONRY OPENING DOOR OPENING AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 HARDWARE STANDARDS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STANDARD OPTIONAL Doors Narrow stile 260 doors prepared for attachment hardware. Medium stile 360 or wide stile 560. Door Sizes Standard sizes shown on page 8. Any size up to 3' 6" x 8' (1067 x 2438) Glass Stops Square glass stops for 1" (25.4) infill. Door Frames TrifabTM VG 451T Center - 2" x 4-1/2" (50.8 x 114.3) for double glazing. Other Kawneer framing systems suitable for door frames may be used. Push-Pulls Single Acting: Single Acting: Architects Classic Hardware "CO-9" Pull and "CP-II" Push Bar. Architects Classic Hardware "CO-9" Pull and "CP" Push Bar. Architects Classic Hardware "CO-12" and "CP-II" push bar. Architects Classic Hardware "CO-12" and "CP" push bar. Architects Classic Hardware "CO-9"/"CO-9" Pulls. Architects Classic Hardware "CO-12"/"CO-12" Pulls. Door Closers Single Acting: Norton 1601 adjustable or 1601 BF adjustable surface closer with back-check and with or without adjustable hold-open. Single Acting: LCN 1260 adjustable LCN 4040 surface closer with or without adjustable hold-open. Standard COC with single acting offset arm. Norton 8100 surface closer with 50% spring power adjustment (for opening forces of less than 8 pounds.) Closer is available with standard back-checks and with or without the hold-open feature. Single Acting: Kawneer top and bottom offset pivots (or) Kawneer top and bottom 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non -removable pin (NRP) (or) Continuous Hinge. Intermediate Pivots/Butts Single Acting: Kawneer intermediate offset pivot (or) Kawneer 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP). Power Transfers Single Acting: Kawneer EL intermediate offset pivot (or) Kawneer EL 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with wire transfer (or) EPT (Electric Power Transfer). Power Supply SP-1000X Power Supply: For use with EL exit devices. Locks Active Leaf Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4) diameter 5 pin cylinders. © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Falcon SC 60 surface closer. Hinging kawneer.com ADMA070 Single Acting: Rixson M-19 or IVES #7215-INT intermediate offset pivot. Adams-Rite #4510 latch lock. Adams-Rite #1850A-500 short throw deadlock. Adams-Rite #1850A-505 hookbolt lock. Adams-Rite #4015 two-point Lock. Adams-Rite #4085 three-point Lock. Kawneer cylinder guard. Kawneer thumbturn (in lieu of cylinder). 9 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 HARDWARE STANDARDS EC 97911-065 STANDARD Locks Inactive Leaf One pair of Kawneer flush bolts in the inactive leaf of a pair of doors. Thresholds A 1/2" x 4" (12.7 x 101.6) aluminum mill finish threshold. Weathering Single Acting: Exit Device Falcon 1690 Concealed Rod Exit Device with or without a rim type cylinder. OPTIONAL Controller is a 3-point locking system consisting of a two point locking device in the inactive leaf in lieu of flush bolts, working in conjunction with the MS 1850A deadlock in the active leaf. This combination provides for greater security than possible with flush bolts and complies with the life safety considerations of building codes which prohibit the use of flush bolts. TM Weathering system in the door and frame consisting of a dense, bulb polymeric material, which remains resilient and retains its weathering ability under temperature extremes. (Complete with an EPDM blade gasket sweep strip applied to the bottom door rail with concealed fasteners). Falcon 1790 Rim Exit Device is a rim type exit device with or without a rim type cylinder. Falcon EL 1690 concealed rod exit device with or without a rim type cylinder. The device is designed for electrified access control and is compatible with most key pad and card reader systems. Falcon EL 1790 rim type exit device with or without a rim type cylinder. The device is designed for electrified access control and is compatible with most key pad and card reader systems. Falcon 1990 is a concealed rod exit device with or without a rim type cylinder. Falcon 2090 is a rim type exit device with or without a rim type cylinder. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Adams Rite 8600 is a concealed rod exit device with or without a rim type cylinder. Adams Rite 8400 is a rim type exit device with or without a rim type cylinder. Optional Exit Device Pulls: Architects Classic style "CO-9" Pull. Architects Classic style "CO-12" Pull. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Exit Device Pulls: Reference Hardware section for additional information ADMA070 kawneer.com © Kawneer Company, Inc., 2015 10 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 PUSH PULL HARDWARE SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR. ARCHITECTS CLASSIC (PUSH PULL SETS) CP-II / CP-II CO-9 / CP CO-12 / CP "CO-9" PULL kawneer.com CO-9 / CP-II CO-12 / CP-II "CO-12" PULL "CP-II" PUSH BAR ADMA070 11 Refer to HARDWARE SECTION for complete hardware information. CP / CP CO-9 / CO-9 CO-12 / CO-12 ARCHITECTS CLASSIC (COMPONENTS) "CP" PUSH BAR "CO-9" PULL "CO-12" PULL RIM LATCH EXIT DEVICE Falcon 1790 Falcon EL 1790 MORTISE EXIT DEVICE Adams-Rite 8400 CONCEALED ROD EXIT DEVICE Falcon 1990 ADMA070 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 EXIT DEVICES EC 97911-065 CONCEALED EXIT DEVICE Adams-Rite 8600 RIM LATCH EXIT DEVICE Falcon 2090 kawneer.com © Kawneer Company, Inc., 2015 CONCEALED ROD EXIT DEVICE Falcon 1690 Falcon EL 1690 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 EXIT DEVICES and EXIT DEVICE PULLS 3-7/8" (98.4) 260 kawneer.com 360 and 560 ADMA070 OPTIONAL DOOR DETAILS OPTIONAL BOTTOM RAIL 069129 450053 450055 4-21/32" (118.3) 1/2" (12.7) 8-1/4" (209.6) 6" (152.4) EC 97911-065 1/2" (12.7) STANDARD BOTTOM RAIL 12" (304.8) 10" (254) 3-1/2" (88.9) 2-1/4" (57.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 260/360/560 InsulcladTM Thermal Entrances 1/2" (12.7) 7-1/2" (190.5) 6-1/2" (165.1) © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. AUGUST, 2015 13 SCALE 3" = 1'-0" OPTIONAL CROSS RAILS THRESHOLDS 4-3/8" (111.1) 4-21/32" (118.3) 14 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 WINDLOAD/DEADLOAD CHARTS EC 97911-065 WINDLOAD ON ENTRANCE FRAMING A = 15 PSF B = 20 PSF C = 25 PSF D = 30 PSF WIDTH IN METERS 1 .5 16 1.5 2 15 4.5 HEIGHT IN FEET 13 4 B C 12 3.5 D 11 E 10 3 9 2.5 8 7 HEIGHT IN METERS A 14 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Charted windload curves are based on allowable stress for aluminum of 15,152 PSI and a L/175 deflection ratio and, in all cases represent the limiting values. Dimensional limits at the stated windloads are for door frame members anchored only at the ends. (720 Pa) (960 Pa) (1200 Pa) (1440 Pa) 452136 2 6 5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN METERS .5 6 1 1.5 2 4.5 4 4 3.5 3 3 2 2.5 1 HEIGHT IN METERS HEIGHT IN FEET 5 452137 2 0 1 2 3 4 5 6 7 8 WIDTH IN FEET ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Height limitations for transom glass over a doorway are based on a maximum 1/16" (1.6) mid-point deflection of a transom bar supporting 1" (25.4) thick double 1/4" (6.4) pane insulating glass bearing on two setting blocks placed at the 1/4-points (i.e. one fourth of the span as measured from each end). To determine height limitations for other types of insulating glass multiply the allowable glass height from the chart times 1.33 for units made with two panes of 3/16" (4.8) thick glass or times 2.0 for units made with two 1/8" (3.2) panes. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DEADLOAD ON TRANSOM BAR AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 THERMAL CHARTS 15 Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 30.4375" (773.1) (DLO) 75.9375" (1928.8) (F.H.) 7'-2" (2184.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. (DLO) Note: 260 Door shown for example 3'-4" (1016.0) (F.W.) Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 30.4375" x 75.9375" = 16.05 ft2 Total Projected Area = 3'-4" x 7'-2" = 23.9 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (16.05 ÷ 23.9)100 = 67% System U-factor vs Percent of Glass Area 0.90 (5.00) 0.80 (4.50) 0.75 N © Kawneer Company, Inc., 2015 0.60 0.55 0.53 0.50 0.45 0.35 (2.50) (2.00) 0.30 0.20 70 67% 65 60 55 Percent of Glass Area Based on 67% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.53 Btu/hr • ft2 • °F kawneer.com (3.00) 0.40 0.25 75 (3.50) ADMA070 50 (1.50) W m2 • °C System U-factor (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) (4.00) 0.65 Btu hr • ft2 • °F System U-factor COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.70 E IGN PL S M E A D EX OR F T O Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.85 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 THERMAL CHARTS EC 97911-065 260 INSULCLADTM DOOR - SINGLE LEAF Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area COG U-factor Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 16 © Kawneer Company, Inc., 2015 System VT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 THERMAL CHARTS Vision Area / Total Area (%) kawneer.com ADMA070 17 260 INSULCLADTM DOOR - SINGLE LEAF System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-065 Overall U-Factor 4 0.48 0.72 0.46 0.71 0.44 0.70 0.42 0.69 0.40 0.67 0.38 0.66 0.36 0.65 0.34 0.64 0.32 0.63 0.30 0.62 0.28 0.60 0.26 0.59 0.24 0.58 0.22 0.57 0.20 0.56 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1000mm wide by 2000mm high (39-3/8" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.52 0.75 0.49 0.70 0.48 0.70 0.45 0.65 0.45 0.65 0.42 0.60 0.42 0.60 0.39 0.55 0.39 0.55 0.36 0.50 0.35 0.50 0.32 0.45 0.32 0.45 0.29 0.40 0.29 0.40 0.26 0.35 0.26 0.35 0.23 0.30 0.22 0.30 0.19 0.25 0.19 0.25 0.16 0.20 0.16 0.20 0.13 0.15 0.13 0.15 0.10 0.10 0.09 0.10 0.06 0.05 0.06 0.05 0.03 ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 260 INSULCLADTM DOOR SINGLE LEAF Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 THERMAL CHARTS 19 360 INSULCLADTM DOOR - SINGLE LEAF Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 Btu hr • ft2 • °F System U-factor COG U-factor © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADMA070 System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADMA070 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 THERMAL CHARTS EC 97911-065 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 20 360 INSULCLADTM DOOR - SINGLE LEAF Vision Area / Total Area (%) AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 360 INSULCLADTM DOOR SINGLE LEAF 0Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.75 0.46 0.74 0.44 0.73 0.42 0.72 0.40 0.71 0.38 0.70 0.36 0.69 0.34 0.68 0.32 0.67 0.30 0.66 0.28 0.65 0.26 0.64 0.24 0.63 0.22 0.62 0.20 0.61 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 21 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1000mm wide by 2000mm high (39-3/8" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.45 0.75 0.42 0.70 0.42 0.70 0.39 0.65 0.40 0.65 0.36 0.60 0.37 0.60 0.33 0.55 0.34 0.55 0.31 0.50 0.31 0.50 0.28 0.45 0.29 0.45 0.25 0.40 0.26 0.40 0.22 0.35 0.23 0.35 0.19 0.30 0.20 0.30 0.17 0.25 0.17 0.25 0.14 0.20 0.15 0.20 0.11 0.15 0.12 0.15 0.08 0.10 0.09 0.10 0.06 0.05 0.06 0.05 0.03 ADMA070 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 THERMAL CHARTS EC 97911-065 560 INSULCLADTM DOOR - SINGLE LEAF Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area COG U-factor Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 22 © Kawneer Company, Inc., 2015 System VT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AUGUST, 2015 260/360/560 InsulcladTM Thermal Entrances EC 97911-065 THERMAL CHARTS Vision Area / Total Area (%) kawneer.com ADMA070 23 560 INSULCLADTM DOOR - SINGLE LEAF System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 260/360/560 InsulcladTM Thermal Entrances AUGUST, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-065 Overall U-Factor 4 0.48 0.78 0.46 0.77 0.44 0.76 0.42 0.75 0.40 0.74 0.38 0.74 0.36 0.73 0.34 0.72 0.32 0.71 0.30 0.70 0.28 0.69 0.26 0.68 0.24 0.68 0.22 0.67 0.20 0.66 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1000mm wide by 2000mm high (39-3/8" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.40 0.75 0.36 0.70 0.38 0.70 0.34 0.65 0.35 0.65 0.31 0.60 0.33 0.60 0.29 0.55 0.31 0.55 0.26 0.50 0.28 0.50 0.24 0.45 0.26 0.45 0.22 0.40 0.23 0.40 0.19 0.35 0.21 0.35 0.17 0.30 0.19 0.30 0.14 0.25 0.16 0.25 0.12 0.20 0.14 0.20 0.10 0.15 0.11 0.15 0.07 0.10 0.09 0.10 0.05 0.05 0.07 0.05 0.02 ADMA070 kawneer.com © Kawneer Company, Inc., 2015 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 560 INSULCLADTM DOOR SINGLE LEAF Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24