260/360/560 Insulclad Thermal Entrances - Architectural Detail Manual

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
FEATURES
Features
• 260 InsulcladTM has 2-11/16" (68.3) vertical stile, 2-13/16" (71.4) top and 4-7/16" (112.7)
bottom rail
• 360 InsulcladTM has 4-1/16" (103.2) vertical stile, 4-1/16" (103.2) top and 7-1/16" (179.4)
bottom rail
• 560 InsulcladTM has 5-9/16" (141.3) vertical stile, 5-9/16" (141.3) top and 7-1/16" (179.4)
bottom rail
• Door is 2-1/4" (57.2) deep
• Dual moment welded corner construction
• Door incorporates an extruded PVC thermal break
• Single acting
• 1" (25.4) infill
• Offset pivots, butt hinges or continuous geared hinge
• MS locks or Exit Device hardware
• Surface mounted or concealed closers
• Architects Classic push/pulls
• Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles
• Polymeric bulb weatherstripping in door frames
• PermanodicTM anodized finishes in seven choices
Optional Features
• Variety of bottom rail and cross rails
• Two-color finish capability
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
• Painted finishes in standard and custom choices
Product Applications
• 260 InsulcladTM – engineered for thermal efficiency in moderate traffic applications such as
offices, stores and apartment buildings
• 360 InsulcladTM – provides thermal efficiency and extra strength for schools, institutions and
other high traffic applications.
• 560 InsulcladTM – designed for thermal efficiency with a monumental visual statement for
banks, libraries or buildings that experience heavy traffic conditions
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMA070
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
BLANK PAGE
EC 97911-065
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
INDEX
3
PICTORIAL VIEW................................................................................ 5
DOOR TYPES/SECT. DIMENSIONS................................................... 6
CONSTRUCTION DETAILS................................................................. 7
ENTRANCE DIMENSIONS.................................................................. 8
HARDWARE STANDARDS............................................................9, 10
PUSH PULL HARDWARE................................................................. 11
EXIT DEVICE..................................................................................... 12
OPTIONAL DOOR DETAILS............................................................. 13
WINDLOAD/DEADLOAD CHARTS................................................... 14
THERMAL CHARTS..................................................................... 15-24
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AUGUST, 2015
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMA070
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
BLANK PAGE
EC 97911-065
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
PICTORIAL VIEW
PIVOT JAMB
SHEAR BLOCK
TRANSOM HEAD
SHEAR BLOCK
TRANSOM BAR
LOCK JAMB
TOP PIVOT
FRAME PORTION
WEATHERING
BOTTOM PIVOT
FRAME PORTION
kawneer.com
THRESHOLD
TOP PIVOT
DOOR PORTION
THRESHOLD
CLIP
INSULCLADTM 260 DOOR
ADMA070
5
TYPICAL
2-1/4"
(57.2)
3-7/8"
(98.4)
2
2-1/8"
(54.0)
6-1/2"
(165.1)
3
3
9/16"
(14.3)
SINGLE ACTING
TYPICAL
2
TOP
ATTACHMENT
TOP
ATTACHMENT
CL
OF CYL.
2
BOTTOM
OF DOOR
1
2
SINGLE ACTING
ADMA070
STANDARD
EXIT DEVICE
C
L
PANIC LOCK
CYLINDER
3
2
3
3
3-1/2"
(88.9)
5"
(127)
AUGUST, 2015
DOOR TYPES/SECTION DIMENSIONS
EC 97911-065
BOTTOM
OF DOOR
2
SINGLE ACTING
kawneer.com
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
C
L OF CRASH BAR FOR
FALCON
C
L OF CRASH BAR FOR
ADAMS RITE
1
1690 = 40-5/8" (1031.9)
STANDARD
LOCATIONS
1790 = 41-5/16" (1049.3)
1
8600 = 41-11/16" (1058.9)
1
8400 = 40-13/16" (1036.6)
360 MEDIUM STILE
41-9/16"
(1042)
44-5/16"
(1125.5)
260/360/560 InsulcladTM Thermal Entrances
© Kawneer Company, Inc., 2015
1
3-1/2"
(88.9)
40-13/16"
(1036.6)
260 NARROW STILE
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2-1/4"
(57.2)
3
5"
(127)
9/16"
(14.3)
STANDARD
LOCATIONS
6-1/2"
(165.1)
TYPICAL
44-5/16"
(1125.5)
6
SCALE 3" = 1' 0"
560 WIDE STILE
1
2-7/32"
(56.4)
TYPICAL
© Kawneer Company, Inc., 2015
3/32"
(2.4)
kawneer.com
1
452041
INSERT
5
3
1
6
4
3
2
1
6
1/8"
(3.2)
3/32"
(2.4)
3
5
ADMA070
2"
(50.8)
7
8
4
2
3
6
1/8"
(3.2)
2"
(50.8)
2
2"
(50.8)
5
1/8"
(3.2)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1
2"
(50.8)
1/2"
(12.7)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
ENTRANCE DETAILS
SCALE 3" = 1'-0"
TRIFABTM VG 451T CENTER FRAMING SHOWN. 260 INSULCLAD SHOWN, 360 AND 560 INSULCLAD SIMILAR.
OTHER FRAMING OPTIONS AVAILABLE. CONSULT YOUR KAWNEER REPRESENTATIVE.
7
8
1
3
6
ELEVATION IS NUMBER KEYED TO DETAILS.
7
2"
(50.8)
8
4
6
7
8
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
ENTRANCE DIMENSIONS
EC 97911-065
SCALE 3" = 1' 0"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DIMENSIONS ARE NOMINAL
MASONRY OPENING
OVERALL FRAME
3/32"
(2.4)
1/8"
(3.2)
WITHOUT TRANSOM
Door Opening Dimension
3' 0" x 7' 0" ( 914 x 2134)
3' 6" x 7' 0" (1067 x 2134)
6' 0" x 7' 0" (1829 x 2134)
Overall Frame Dimension
3' 4" x 7' 2" (1016 x 2184)
3' 10" x 7' 2" (1168 x 2184)
6' 4" x 7' 2" (1930 x 2184)
Masonry Opening Dimension
3' 4-1/2" x 7' 2-1/4" (1029 x 2191)
3' 10-1/2" x 7' 2-1/4" (1181 x 2191)
6' 4-1/2" x 7' 2-1/4" (1943 x 2191)
WITH TRANSOM
Door Opening Dimension
Unchanged from above.
Overall Frame Dimension
Add 3' 2" (965) to above heights.
Masonry Opening Dimension
Add 3' 2-1/2" (978) to above heights.
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
STANDARD SIZES (TRIFABTM VG 451T CENTER FRAMES)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1/2"
(12.7)
3/16"
(4.3)
1/8"
(3.2)
DOOR OPENING
3/32"
(2.4)
OVERALL FRAME
MASONRY OPENING
DOOR OPENING
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
HARDWARE STANDARDS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
STANDARD
OPTIONAL
Doors
Narrow stile 260 doors prepared for attachment hardware.
Medium stile 360 or wide stile 560.
Door Sizes
Standard sizes shown on page 8.
Any size up to 3' 6" x 8' (1067 x 2438)
Glass Stops
Square glass stops for 1" (25.4) infill.
Door Frames
TrifabTM VG 451T Center - 2" x 4-1/2" (50.8 x 114.3) for double
glazing.
Other Kawneer framing systems suitable for door frames may
be used.
Push-Pulls
Single Acting:
Single Acting:
Architects Classic Hardware "CO-9" Pull and
"CP-II" Push Bar.
Architects Classic Hardware "CO-9" Pull and
"CP" Push Bar.
Architects Classic Hardware
"CO-12" and "CP-II" push bar.
Architects Classic Hardware
"CO-12" and "CP" push bar.
Architects Classic Hardware
"CO-9"/"CO-9" Pulls.
Architects Classic Hardware
"CO-12"/"CO-12" Pulls.
Door Closers
Single Acting:
Norton 1601 adjustable or 1601 BF
adjustable surface closer with back-check
and with or without adjustable hold-open.
Single Acting:
LCN 1260 adjustable
LCN 4040 surface closer with or without
adjustable hold-open.
Standard COC with single acting offset arm.
Norton 8100 surface closer with 50% spring
power adjustment (for opening forces of
less than 8 pounds.) Closer is available with
standard back-checks and with or without
the hold-open feature.
Single Acting:
Kawneer top and bottom offset pivots (or)
Kawneer top and bottom 4 1/2" x 4" (114.3
x 101.6) ball bearing butt hinge with non
-removable pin (NRP) (or)
Continuous Hinge.
Intermediate
Pivots/Butts
Single Acting:
Kawneer intermediate offset pivot (or)
Kawneer 4-1/2" x 4" (114.3 x 101.6) ball
bearing butt hinge with non-removable pin
(NRP).
Power
Transfers
Single Acting:
Kawneer EL intermediate offset pivot (or)
Kawneer EL 4-1/2" x 4" (114.3 x 101.6) ball
bearing butt hinge with wire transfer (or)
EPT (Electric Power Transfer).
Power Supply
SP-1000X Power Supply: For use with EL exit devices.
Locks Active Leaf
Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4)
diameter 5 pin cylinders.
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Falcon SC 60 surface closer.
Hinging
kawneer.com
ADMA070
Single Acting:
Rixson M-19 or IVES #7215-INT
intermediate offset pivot.
Adams-Rite #4510 latch lock.
Adams-Rite #1850A-500 short throw deadlock.
Adams-Rite #1850A-505 hookbolt lock.
Adams-Rite #4015 two-point Lock.
Adams-Rite #4085 three-point Lock.
Kawneer cylinder guard.
Kawneer thumbturn (in lieu of cylinder).
9
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
HARDWARE STANDARDS
EC 97911-065
STANDARD
Locks Inactive Leaf
One pair of Kawneer flush bolts in the
inactive leaf of a pair of doors.
Thresholds
A 1/2" x 4" (12.7 x 101.6) aluminum mill
finish threshold.
Weathering
Single
Acting:
Exit Device
Falcon 1690 Concealed Rod Exit
Device with or without a rim type cylinder.
OPTIONAL
Controller is a 3-point locking system consisting of a two point locking device in the
inactive leaf in lieu of flush bolts, working in conjunction with the MS 1850A deadlock
in the active leaf. This combination provides for greater security than possible with
flush bolts and complies with the life safety considerations of building codes which
prohibit the use of flush bolts.
TM
Weathering system in the
door and frame consisting of a
dense, bulb polymeric material,
which remains resilient and
retains its weathering ability
under temperature extremes.
(Complete with an EPDM blade
gasket sweep strip applied
to the bottom door rail with
concealed fasteners).
Falcon 1790 Rim Exit Device is a rim
type exit device with or without a rim type
cylinder.
Falcon EL 1690 concealed rod exit device with or without a rim type cylinder. The
device is designed for electrified access control and is compatible with most key pad
and card reader systems.
Falcon EL 1790 rim type exit device with or without a rim type cylinder. The device is
designed for electrified access control and is compatible with most key pad and card
reader systems.
Falcon 1990 is a concealed rod exit device with or without a rim type cylinder.
Falcon 2090 is a rim type exit device with or without a rim type cylinder.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Adams Rite 8600 is a concealed rod exit device with or without a rim type cylinder.
Adams Rite 8400 is a rim type exit device with or without a rim type cylinder.
Optional Exit Device Pulls:
Architects Classic style "CO-9" Pull.
Architects Classic style "CO-12" Pull.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Exit Device Pulls:
Reference Hardware section for additional information
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
10
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
PUSH PULL HARDWARE
SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR.
ARCHITECTS CLASSIC (PUSH PULL SETS)
CP-II / CP-II
CO-9 / CP
CO-12 / CP
"CO-9"
PULL
kawneer.com
CO-9 / CP-II
CO-12 / CP-II
"CO-12"
PULL
"CP-II" PUSH BAR
ADMA070
11
Refer to HARDWARE SECTION for
complete hardware information.
CP / CP
CO-9 / CO-9
CO-12 / CO-12
ARCHITECTS CLASSIC (COMPONENTS)
"CP" PUSH BAR
"CO-9"
PULL
"CO-12"
PULL
RIM LATCH EXIT DEVICE
Falcon 1790
Falcon EL 1790
MORTISE EXIT DEVICE
Adams-Rite 8400
CONCEALED ROD EXIT DEVICE
Falcon 1990
ADMA070
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
EXIT DEVICES
EC 97911-065
CONCEALED EXIT DEVICE
Adams-Rite 8600
RIM LATCH EXIT DEVICE
Falcon 2090
kawneer.com
© Kawneer Company, Inc., 2015
CONCEALED ROD EXIT DEVICE
Falcon 1690
Falcon EL 1690
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
EXIT DEVICES and EXIT DEVICE PULLS
3-7/8"
(98.4)
260
kawneer.com
360 and 560
ADMA070
OPTIONAL DOOR DETAILS
OPTIONAL BOTTOM RAIL
069129
450053
450055
4-21/32"
(118.3)
1/2"
(12.7)
8-1/4"
(209.6)
6"
(152.4)
EC 97911-065
1/2"
(12.7)
STANDARD BOTTOM RAIL
12"
(304.8)
10"
(254)
3-1/2"
(88.9)
2-1/4"
(57.2)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
260/360/560 InsulcladTM Thermal Entrances
1/2"
(12.7)
7-1/2"
(190.5)
6-1/2"
(165.1)
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
AUGUST, 2015
13
SCALE 3" = 1'-0"
OPTIONAL CROSS RAILS
THRESHOLDS
4-3/8"
(111.1)
4-21/32"
(118.3)
14
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
WINDLOAD/DEADLOAD CHARTS
EC 97911-065
WINDLOAD ON ENTRANCE FRAMING
A = 15 PSF
B = 20 PSF
C = 25 PSF
D = 30 PSF
WIDTH IN METERS
1
.5
16
1.5
2
15
4.5
HEIGHT IN FEET
13
4
B
C
12
3.5
D
11
E
10
3
9
2.5
8
7
HEIGHT IN METERS
A
14
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Charted windload curves are based on allowable stress for aluminum of 15,152 PSI and a L/175 deflection ratio and, in all cases represent the
limiting values. Dimensional limits at the stated windloads are for door frame members anchored only at the ends.
(720 Pa)
(960 Pa)
(1200 Pa)
(1440 Pa)
452136
2
6
5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WIDTH IN METERS
.5
6
1
1.5
2
4.5
4
4
3.5
3
3
2
2.5
1
HEIGHT IN METERS
HEIGHT IN FEET
5
452137
2
0
1
2
3
4
5
6
7
8
WIDTH IN FEET
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Height limitations for transom glass over a doorway are based on a maximum 1/16" (1.6) mid-point deflection of a transom bar supporting 1" (25.4)
thick double 1/4" (6.4) pane insulating glass bearing on two setting blocks placed at the 1/4-points (i.e. one fourth of the span as measured from each
end). To determine height limitations for other types of insulating glass multiply the allowable glass height from the chart times 1.33 for units made with
two panes of 3/16" (4.8) thick glass or times 2.0 for units made with two 1/8" (3.2) panes.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
DEADLOAD ON TRANSOM BAR
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
THERMAL CHARTS
15
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
30.4375"
(773.1)
(DLO)
75.9375"
(1928.8)
(F.H.)
7'-2"
(2184.4)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
(DLO)
Note: 260 Door shown for example
3'-4"
(1016.0)
(F.W.)
Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F
Total Daylight Opening
= 30.4375" x 75.9375" = 16.05 ft2
Total Projected Area
= 3'-4" x 7'-2" = 23.9 ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)100
= (16.05 ÷ 23.9)100 = 67%
System U-factor vs Percent of Glass Area
0.90
(5.00)
0.80
(4.50)
0.75
N
© Kawneer Company, Inc., 2015
0.60
0.55
0.53
0.50
0.45
0.35
(2.50)
(2.00)
0.30
0.20
70
67%
65
60
55
Percent of Glass Area
Based on 67% glass and center of glass (COG) U-factor of 0.42
System U-factor is equal to 0.53 Btu/hr • ft2 • °F
kawneer.com
(3.00)
0.40
0.25
75
(3.50)
ADMA070
50
(1.50)
W
m2 • °C
System U-factor
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
(4.00)
0.65
Btu
hr • ft2 • °F
System U-factor
COG
U-factor
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.70
E IGN
PL S
M E
A D
EX OR
F
T
O
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.85
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
THERMAL CHARTS
EC 97911-065
260 INSULCLADTM DOOR - SINGLE LEAF
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
COG
U-factor
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
16
© Kawneer Company, Inc., 2015
System VT
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
THERMAL CHARTS
Vision Area / Total Area (%)
kawneer.com
ADMA070
17
260 INSULCLADTM DOOR - SINGLE LEAF
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-065
Overall U-Factor 4
0.48
0.72
0.46
0.71
0.44
0.70
0.42
0.69
0.40
0.67
0.38
0.66
0.36
0.65
0.34
0.64
0.32
0.63
0.30
0.62
0.28
0.60
0.26
0.59
0.24
0.58
0.22
0.57
0.20
0.56
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1000mm wide by
2000mm high (39-3/8" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.52
0.75
0.49
0.70
0.48
0.70
0.45
0.65
0.45
0.65
0.42
0.60
0.42
0.60
0.39
0.55
0.39
0.55
0.36
0.50
0.35
0.50
0.32
0.45
0.32
0.45
0.29
0.40
0.29
0.40
0.26
0.35
0.26
0.35
0.23
0.30
0.22
0.30
0.19
0.25
0.19
0.25
0.16
0.20
0.16
0.20
0.13
0.15
0.13
0.15
0.10
0.10
0.09
0.10
0.06
0.05
0.06
0.05
0.03
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
260 INSULCLADTM DOOR
SINGLE LEAF
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
THERMAL CHARTS
19
360 INSULCLADTM DOOR - SINGLE LEAF
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
Btu
hr • ft2 • °F
System U-factor
COG
U-factor
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADMA070
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMA070
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
THERMAL CHARTS
EC 97911-065
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
20
360 INSULCLADTM DOOR - SINGLE LEAF
Vision Area / Total Area (%)
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
360 INSULCLADTM DOOR SINGLE LEAF
0Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.75
0.46
0.74
0.44
0.73
0.42
0.72
0.40
0.71
0.38
0.70
0.36
0.69
0.34
0.68
0.32
0.67
0.30
0.66
0.28
0.65
0.26
0.64
0.24
0.63
0.22
0.62
0.20
0.61
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
21
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1000mm wide by
2000mm high (39-3/8" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.45
0.75
0.42
0.70
0.42
0.70
0.39
0.65
0.40
0.65
0.36
0.60
0.37
0.60
0.33
0.55
0.34
0.55
0.31
0.50
0.31
0.50
0.28
0.45
0.29
0.45
0.25
0.40
0.26
0.40
0.22
0.35
0.23
0.35
0.19
0.30
0.20
0.30
0.17
0.25
0.17
0.25
0.14
0.20
0.15
0.20
0.11
0.15
0.12
0.15
0.08
0.10
0.09
0.10
0.06
0.05
0.06
0.05
0.03
ADMA070
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
THERMAL CHARTS
EC 97911-065
560 INSULCLADTM DOOR - SINGLE LEAF
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
COG
U-factor
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
22
© Kawneer Company, Inc., 2015
System VT
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AUGUST, 2015
260/360/560 InsulcladTM Thermal Entrances
EC 97911-065
THERMAL CHARTS
Vision Area / Total Area (%)
kawneer.com
ADMA070
23
560 INSULCLADTM DOOR - SINGLE LEAF
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
260/360/560 InsulcladTM Thermal Entrances
AUGUST, 2015
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-065
Overall U-Factor 4
0.48
0.78
0.46
0.77
0.44
0.76
0.42
0.75
0.40
0.74
0.38
0.74
0.36
0.73
0.34
0.72
0.32
0.71
0.30
0.70
0.28
0.69
0.26
0.68
0.24
0.68
0.22
0.67
0.20
0.66
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1000mm wide by
2000mm high (39-3/8" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.40
0.75
0.36
0.70
0.38
0.70
0.34
0.65
0.35
0.65
0.31
0.60
0.33
0.60
0.29
0.55
0.31
0.55
0.26
0.50
0.28
0.50
0.24
0.45
0.26
0.45
0.22
0.40
0.23
0.40
0.19
0.35
0.21
0.35
0.17
0.30
0.19
0.30
0.14
0.25
0.16
0.25
0.12
0.20
0.14
0.20
0.10
0.15
0.11
0.15
0.07
0.10
0.09
0.10
0.05
0.05
0.07
0.05
0.02
ADMA070
kawneer.com
© Kawneer Company, Inc., 2015
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
560 INSULCLADTM DOOR
SINGLE LEAF
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
24