GaAs INTEGRATED CIRCUIT
PG2164T5N
DPDT SWITCH FOR 2.4 GHz AND 6 GHz DUAL-BAND WIRELESS LAN
DESCRIPTION
The PG2164T5N is a GaAs MMIC DPDT (Double Pole Double Throw) switch which was developed for 2.4 GHz
and 6 GHz dual-band wireless LAN. This device can operate frequency from 2.4 GHz band and 6 GHz band, having
the low insertion loss and high isolation.
This device is housed in a 6-pin plastic TSON (Thin Small Out-line Non-leaded) package. And this package is
able to high-density surface mounting.
FEATURES
• Operating frequency
: f = 2.4 to 2.5 GHz and 4.9 to 6.0 GHz
• Switch control voltage
: Vcont (H) = 2.8 to 5.0 V (3.0 V TYP.)
: Vcont (L) = 0.3 to 0.3 V (0 V TYP.)
• Low insertion loss
: Lins1 = 0.50 dB TYP. @ f = 2.4 to 2.5 GHz, Vcont (H) = 3.0 V, Vcont (L) = 0 V
: Lins2 = 0.70 dB TYP. @ f = 4.9 to 6.0 GHz, Vcont (H) = 3.0 V, Vcont (L) = 0 V
• High isolation
: ISL1 = 25 dB TYP. @ f = 2.4 to 2.5 GHz, Vcont (H) = 3.0 V, Vcont (L) = 0 V
: ISL2 = 17 dB TYP. @ f = 4.9 to 6.0 GHz, Vcont (H) = 3.0 V, Vcont (L) = 0 V
• Handling power
: Pin (1 dB) = +31.0 dBm TYP. @ f = 2.5 GHz, Vcont (H) = 3.0 V, Vcont (L) = 0 V
: Pin (1 dB) = +29.0 dBm TYP. @ f = 6.0 GHz, Vcont (H) = 3.0 V, Vcont (L) = 0 V
• High-density surface mounting : 6-pin plastic TSON package (1.5  1.5  0.37 mm)
APPLICATION
• Dual-band wireless LAN (IEEE802.11a + b/g)
ORDERING INFORMATION
Part Number
Order Number
PG2164T5N-E2
PG2164T5N-E2-A
Package
6-pin plastic TSON
(Pb-Free)
Marking
G5B
Supplying Form
 Embossed tape 8 mm wide
 Pin 1, 6 face the perforation side of the tape
 Qty 3 kpcs/reel
Remark To order evaluation samples, contact your nearby sales office.
Part number for sample order: PG2164T5N-A
Caution: Observe precautions when handling because these devices are sensitive to electrostatic discharge
Document No. PG10636EJ02V0DS (2nd edition)
Date Published February 2008 NS
The mark <R> shows major revised points.
The revised points can be easily searched by copying an "<R>" in the PDF file and specifying it in the "Find what:" field.
PG2164T5N
PIN CONNECTIONS AND INTERNAL BLOCK DIAGRAM
Pin No.
Pin Name
1
ANT2
2
Vcont2
3
OUT2 (RX)
4
OUT1 (TX)
5
Vcont1
6
ANT1
Remark Exposed pad : GND
TRUTH TABLE
Vcont1
Vcont2
ANT1OUT1 (TX)
ANT1 OUT2 (RX)
ANT2 OUT1 (TX)
ANT2OUT2 (RX)
High
Low
OFF
ON
ON
OFF
Low
High
ON
OFF
OFF
ON
ABSOLUTE MAXIMUM RATINGS (T A = +25C, unless otherwise specified)
Parameter
Symbol
Ratings
Unit
Vcont
6.0 to +6.0
V
Input Power
Pin
+32
dBm
Operating Ambient Temperature
TA
45 to +85
C
Storage Temperature
Tstg
55 to +135
C
Switch Control Voltage
RECOMMENDED OPERATING RANGE (T A = +25C, unless otherwise specified)
Parameter
Symbol
MIN.
TYP.
MAX.
Unit
Switch Control Voltage (H)
Vcont (H)
2.8
3.0
5.0
V
Switch Control Voltage (L)
Vcont (L)
0.3
0
0.3
V
Operating Frequency 1
f1
2.4

2.5
GHz
Operating Frequency 2
f2
4.9

6.0
GHz
2
Data Sheet PG10636EJ02V0DS
PG2164T5N
ELECTRICAL CHARACTERISTICS
(T A = +25C, Vcont (H) = 3.0 V, Vcont
otherwise specified)
Parameter
Symbol
(L)
= 0 V, Z0 = 50 , DC blocking capacitors = 4 pF, unless
Test Conditions
MIN.
TYP.
MAX.
Unit
Insertion Loss 1
Lins1
f = 2.4 to 2.5 GHz

0.50
0.75
dB
Insertion Loss 2
Lins2
f = 4.9 to 6.0 GHz

0.70
1.00
dB
Isolation 1 (ANT to OUT)
ISL1
f = 2.4 to 2.5 GHz
22
25

dB
Isolation 2 (ANT to OUT)
ISL2
f = 4.9 to 6.0 GHz
14
17

dB
Isolation 3 (ANT1 to ANT2, TX to RX)
ISL3
f = 2.4 to 2.5 GHz
22
25

dB
Isolation 4 (ANT1 to ANT2, TX to RX)
ISL4
f = 4.9 to 6.0 GHz
15
17

dB
Input Return Loss 1
RLin1
f = 2.4 to 2.5 GHz

15

dB
Input Return Loss 2
RLin2
f = 4.9 to 6.0 GHz

15

dB
Output Return Loss 1
RLout1
f = 2.4 to 2.5 GHz

15

dB
Output Return Loss 2
RLout2
f = 4.9 to 6.0 GHz

15

dB
1 dB Loss Compression
Note
Input Power 1
Pin (1 dB) 1 f = 2.4 to 2.5 GHz

+31.0

dBm
1 dB Loss Compression
Note
Input Power 2
Pin (1 dB) 2 f = 4.9 to 6.0 GHz

+29.0

dBm

+50

dBm

0.1
1.0
A

50

ns
Input 3rd Order Intercept Point
IIP3
f1 = 2 500 MHz, f2 = 2 501 MHz,
Pin (1 tone) = +20 dBm
Switch Control Current
Icont
Switch Control Speed
tSW
50% CTL to 90/10%
Note Pin (1 dB) is measured the input power level when the insertion loss increases more 1 dB than that of linear
range.
Caution This device is used it is necessary to use DC blocking capacitors.
Data Sheet PG10636EJ02V0DS
3
PG2164T5N
EVALUATION CIRCUIT
The application circuits and their parameters are for reference only and are not intended for use in actual design-ins.
4
Data Sheet PG10636EJ02V0DS
PG2164T5N
MOUNTING PAD AND SOLDER MASK LAYOUT DIMENSIONS
6-PIN PLASTIC TSON (UNIT: mm)
Remark The mounting pad and solder mask layouts in this document are for reference only.
Data Sheet PG10636EJ02V0DS
5
PG2164T5N
<R>
PACKAGE DIMENSIONS
6-PIN PLASTIC TSON (UNIT: mm)
6
Data Sheet PG10636EJ02V0DS
PG2164T5N
RECOMMENDED SOLDERING CONDITIONS
This product should be soldered and mounted under the following recommended conditions.
For soldering
methods and conditions other than those recommended below, contact your nearby sales office.
Soldering Method
Infrared Reflow
Wave Soldering
Partial Heating
Soldering Conditions
Condition Symbol
Peak temperature (package surface temperature)
: 260C or below
Time at peak temperature
: 10 seconds or less
Time at temperature of 220C or higher
: 60 seconds or less
Preheating time at 120 to 180C
: 12030 seconds
Maximum number of reflow processes
: 3 times
Maximum chlorine content of rosin flux (% mass)
: 0.2%(Wt.) or below
Peak temperature (molten solder temperature)
: 260C or below
Time at peak temperature
: 10 seconds or less
Preheating temperature (package surface temperature)
: 120C or below
Maximum number of flow processes
: 1 time
Maximum chlorine content of rosin flux (% mass)
: 0.2%(Wt.) or below
Peak temperature (terminal temperature)
: 350C or below
Soldering time (per side of device)
: 3 seconds or less
Maximum chlorine content of rosin flux (% mass)
: 0.2%(Wt.) or below
IR260
WS260
HS350
Caution Do not use different soldering methods together (except for partial heating).
Data Sheet PG10636EJ02V0DS
7
PG2164T5N
Caution GaAs Products
This product uses gallium arsenide (GaAs).
GaAs vapor and powder are hazardous to human health if inhaled or ingested, so please observe the
following points.
• Follow related laws and ordinances when disposing of the product. If there are no applicable laws
and/or ordinances, dispose of the product as recommended below.
1. Commission a disposal company able to (with a license to) collect, transport and dispose of
materials that contain arsenic and other such industrial waste materials.
2. Exclude the product from general industrial waste and household garbage, and ensure that the
product is controlled (as industrial waste subject to special control) up until final disposal.
• Do not burn, destroy, cut, crush, or chemically dissolve the product.
• Do not lick the product or in any way allow it to enter the mouth.
8
Data Sheet PG10636EJ02V0DS
NOTICE
1.
Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation of semiconductor products and
application examples. You are fully responsible for the incorporation of these circuits, software, and information in the design of your equipment. California
Eastern Laboratories and Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits,
software, or information.
2. California Eastern Laboratories has used reasonable care in preparing the information included in this document, but California Eastern Laboratories does
not warrant that such information is error free. California Eastern Laboratories and Renesas Electronics assumes no liability whatsoever for any damages
incurred by you resulting from errors in or omissions from the information included herein.
3. California Eastern Laboratories and Renesas Electronics do not assume any liability for infringement of patents, copyrights, or other intellectual property
rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document. No license, express,
implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights of California Eastern Laboratories or Renesas
Electronics or others.
4. You should not alter, modify, copy, or otherwise misappropriate any Renesas Electronics product, whether in whole or in part. California Eastern
Laboratories and Renesas Electronics assume no responsibility for any losses incurred by you or third parties arising from such alteration, modification, copy
or otherwise misappropriation of Renesas Electronics product.
5. Renesas Electronics products are classified according to the following two quality grades: “Standard” and “High Quality”. The recommended applications
for each Renesas Electronics product depends on the product’s quality grade, as indicated below. “Standard”: Computers; office equipment; communications
equipment; test and measurement equipment; audio and visual equipment; home electronic appliances; machine tools; personal electronic equipment; and
industrial robots etc. “High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic control systems; anti-disaster systems; anti-crime
systems; and safety equipment etc. Renesas Electronics products are neither intended nor authorized for use in products or systems that may pose a direct
threat to human life or bodily injury (artificial life support devices or systems, surgical implantations etc.), or may cause serious property damages (nuclear
reactor control systems, military equipment etc.). You must check the quality grade of each Renesas Electronics product before using it in a particular
application. You may not use any Renesas Electronics product for any application for which it is not intended. California Eastern Laboratories and Renesas
Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product
for which the product is not intended by California Eastern Laboratories or Renesas Electronics.
6. You should use the Renesas Electronics products described in this document within the range specified by California Eastern Laboratories, especially with
respect to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation characteristics, installation and other product
characteristics. California Eastern Laboratories shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products
beyond such specified ranges.
7. Although Renesas Electronics endeavors to improve the quality and reliability of its products, semiconductor products have specific characteristics such as
the occurrence of failure at a certain rate and malfunctions under certain use conditions. Further, Renesas Electronics products are not subject to radiation
resistance design. Please be sure to implement safety measures to guard them against the possibility of physical injury, and injury or damage caused by
fire in the event of the failure of a Renesas Electronics product, such as safety design for hardware and software including but not limited to redundancy,
fire control and malfunction prevention, appropriate treatment for aging degradation or any other appropriate measures. Because the evaluation of
microcomputer software alone is very difficult, please evaluate the safety of the final products or systems manufactured by you.
8. Please contact a California Eastern Laboratories sales office for details as to environmental matters such as the environmental compatibility of each Renesas
Electronics product. Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of
controlled substances, including without limitation, the EU RoHS Directive. California Eastern Laboratories and Renesas Electronics assume no liability for
damages or losses occurring as a result of your noncompliance with applicable laws and regulations.
9. Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited
under any applicable domestic or foreign laws or regulations. You should not use Renesas Electronics products or technology described in this document
for any purpose relating to military applications or use by the military, including but not limited to the development of weapons of mass destruction. When
exporting the Renesas Electronics products or technology described in this document, you should comply with the applicable export control laws and
regulations and follow the procedures required by such laws and regulations.
10. It is the responsibility of the buyer or distributor of California Eastern Laboratories, who distributes, disposes of, or otherwise places the Renesas Electronics
product with a third party, to notify such third party in advance of the contents and conditions set forth in this document, California Eastern Laboratories and
Renesas Electronics assume no responsibility for any losses incurred by you or third parties as a result of unauthorized use of Renesas Electronics products.
11. This document may not be reproduced or duplicated in any form, in whole or in part, without prior written consent of California Eastern Laboratories.
12. Please contact a California Eastern Laboratories sales office if you have any questions regarding the information contained in this document or Renesas
Electronics products, or if you have any other inquiries.
NOTE 1: “Renesas Electronics” as used in this document means Renesas Electronics Corporation and also includes its majority-owned subsidiaries.
NOTE 2: “Renesas Electronics product(s)” means any product developed or manufactured by or for Renesas Electronics.
NOTE 3: Products and product information are subject to change without notice.
CEL Headquarters • 4590 Patrick Henry Drive, Santa Clara, CA 95054 • Phone (408) 919-2500 • www.cel.com
For a complete list of sales offices, representatives and distributors,
Please visit our website: www.cel.com/contactus